Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 295 NW AMBLESIDE DR
LAKE CITY, FL 32055
Parcel #: 02275-137
Acres: 2.06
Owner: Hall Derrick L & Kristi K
Subdivision: Cobblestone Unit 2
Zoning: RR
Flood Zone: X
District: 1
Application #: 47682
Permit #: 000040950
Related Permit: Culvert: 000040791
Submitted: Friday, October 30, 2020
Issued: Wednesday, December 2, 2020
Expires: Monday, November 8, 2021
Completed: Monday, November 8, 2021
Status: Completed
Septic Release? Yes
Notes:
PLEASE REQUEST A FINAL DRIVEWAY INSPECTION PRIOR TO PERMANENT POWER CULVERT PERMIT NUMBER 40791....
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2478
Total Area (Sqft) 3655
Stories 1
Building Height 18
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 110' (from road)
Setback Side 1 240' (from road)
Septic# (00-0000) or (X00-000) 20-0922
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0283D
In floodway N
Review Notes
10/30/2020 Application pending.
10/30/2020 Point Review - Received-Hard Copy Application
11/16/2020 Plan Review - Reviewed
11/17/2020 Zoning Review - Reviewed
11/18/2020 Final Review - Documents Required
12/1/2020 Final Review - Payment Needed
12/2/2020 Permit Issued Permit #000040950 created and approved.
4/7/2021 Point Review - Received-Hard Copy Application NEEDED: ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL- REC'D 12/01/2020 CULVERT PERMIT PURCHASED 10.26.20- AWAITS FINAL -40791
9/30/2021 Final Review - Payment Needed NEEDED: ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL- REC'D 12/01/2020 CULVERT PERMIT PURCHASED 10.26.20- AWAITS FINAL -40791
Contractors
Name/ Business License Title Role
Gerald M Smith Sr
S&s Construction Llc
County License & State License & Liability Insurance Expired.
CBC1254161 Building Contractor Contractor
Lyndon J Rainbolt
Rainbolt Tech Services,air Stream
County License & State License & Liability Insurance & Workers Comp Expired.
EC13001835 Electrical Contractor Subcontractor
Daniel Mossburg
Live Oak Plumbing, Inc.
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CFC1427438 Plumbing Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Derrick L Hall
Commercial Equipment Repair, Inc.
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CAC1820005 Cert. A/c Class “b” Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 10/27/2020
Passed: Electrical - Temporary Service Anthony Aslan 1/6/2021
Release to power company Anthony Aslan 1/6/2021
Passed: Building - Footer Anthony Aslan 1/11/2021
Passed: Engineering - Setbacks Anthony Aslan 1/11/2021
Failed: Plumbing/Gas - 1st Underground Rough–In No Water In Lower Fixtures. Anthony Aslan 1/28/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 1/29/2021
Passed: Building - Slab Anthony Aslan 2/5/2021
Passed: Building - Ext Strapping/Wall Sheathing Need To Call Strapping Inspection For Back Porch. Anthony Aslan 3/8/2021
Passed: Plumbing/Gas - 2nd Rough-In Back Porch Post Are Strapped Troy Crews 4/6/2021
Passed: Plumbing/Gas - Tub Set/Shower Pan Troy Crews 4/6/2021
Cancelled: Electrical - 1st Underground Rough–In Troy Crews 4/6/2021
Cancelled: Mechanical - Rough In Troy Crews 4/6/2021
Cancelled: Engineering - Spot Check Troy Crews 4/6/2021
Failed: Building - Framing Need H2.5, Anchor Bolts?, Gridder Truss Strapping, Diaphragm Bracing Gables. Anthony Aslan 4/6/2021
Passed: Building - Framing Made Corrections, Rev'd Letter Anthony Aslan 4/22/2021
Failed: Mechanical - Rough In 1-exhaust Fans Need Metal Strapping And Sealed With 181 Tape. 2-main Supply Trunk Needs Metal Hanging Strapping, Metal Duct Can't Be Strapped With Web Cloth. 3-dryer Vent Needs Metal Hanging Strap, Can't Use Web Cloth On Dryer Pipe. 4-mini Split Line Set Needs To Be Strapped Up, And Drain Line Insulated 5-supply And Return Boots Need Foam Gasket.. Anthony Aslan 4/27/2021
Passed: Electrical - 2nd Rough-In Anthony Aslan 4/27/2021
Passed: Mechanical - Rough In Corrections Made Anthony Aslan 5/3/2021
Passed: Building - Insulation Anthony Aslan 5/4/2021
Cancelled: Electrical - 2nd Rough-In Anthony Aslan 8/13/2021
Passed: Electrical - Permanent Power Need Septic Release Anthony Aslan 8/13/2021
Release to power company Driveway Final Completed 09.30.21 Anthony Aslan 9/30/2021
Passed: Engineering - Final Driveway Mccormick, David 9/30/2021
Septic Release Inspection Health Dept 9/30/2021
Passed: Building - Final Outlet Cover In Laundry And Under Stairwell. Anthony Aslan 11/3/2021
Certificate-Release Certificate Rec'd Pics Anthony Aslan 11/8/2021
Documents
File Name Date File Size
Owner And Contractor Signature Page 20201228 091146.pdf 2023.12.26 454.18kB
Plans 2020-12-31 15.37.59.976.pdf 2023.12.26 7.18MB
Owner And Contractor Signature Page 20201030 124034.pdf 2023.12.26 144.82kB
Recorded Deed 20201228 091346.pdf 2023.12.26 367.41kB
Bfe Converstion Lot 37 2020-11-17 14.22.14.839.pdf 2023.12.26 34.24kB
Site Plan 20201228 091346.pdf 2023.12.26 146.03kB
Blower Door Results 2021-11-04 14.41.18.480.pdf 2023.12.26 230.30kB
40950-1 Termite Slab 2021-02-08 08.41.17.847.jpg 2023.12.26 26.82kB
Residential Or Commercial Checklist 20201228 091446.pdf 2023.12.26 1.76MB
40950 Pad Clearance 2021-11-08 12.16.35.728.heic 2023.12.26 2.97MB
Property Appraiser Parcel Details Printed Page 20201228 091245.pdf 2023.12.26 392.97kB
Recorded Notice Of Commencement 20201228 091347.pdf 2023.12.26 311.03kB
911 Address Form 20201228 091247.pdf 2023.12.26 275.74kB
Truss Engineering 20201228 091746.pdf 2023.12.26 20.09MB
Energy Code Forms 20201228 091546.pdf 2023.12.26 1.53MB
Original Permit 20201202.pdf 2023.12.26 42.65kB
Recorded Deed 20201030 122909.pdf 2023.12.26 55.17kB
Certificate Of Occupancy 20211108.pdf 2023.12.26 62.29kB
Power Release-release To Power Company 20210930.pdf 2023.12.26 39.01kB
Titan Bolt Letter 40950(1) 2021-04-08 13.08.36.974.pdf 2023.12.26 69.04kB
Subcontractor Form 20201228 091246.pdf 2023.12.26 357.40kB
Power Release-electrical-temporary Service 20210106.pdf 2023.12.26 38.87kB
Subcontractor Form 20210226 090245.pdf 2023.12.26 331.67kB
Backup Material 20201228 091347.pdf 2023.12.26 243.99kB
Locking Caps 2021-11-08 12.16.36.837.heic 2023.12.26 104.11kB
Subcontractor Form 20201228 091446.pdf 2023.12.26 360.01kB
Application Information Page 20201228 091148.pdf 2023.12.26 349.28kB
Manual J Forms 20201228 091547.pdf 2023.12.26 1.49MB
Septic Approval Paperwork 20201201 041548.pdf 2023.12.26 439.25kB