Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 525 SW HUNTER RD
LAKE CITY, FL 32024
Parcel #: 02411-012
Acres: 2.00
Owner: Dustin & Emily Nickodam
Subdivision:
Zoning: A-3
Flood Zone: X
District: 2
Application #: 48022
Permit #: 000041275
Related Permit: Culvert Waiver: 000041276
Submitted: Wednesday, January 6, 2021
Issued: Monday, February 8, 2021
Expires: Friday, December 17, 2021
Completed: Friday, December 17, 2021
Status: Completed
Septic Release? Yes
Notes:
SPECIAL FAMILY LOT 2103 APPROVED FOR GRANDCHILD
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0260C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1.5
Heated Area (Sqft) 2033
Total Area (Sqft) 3043
Building Height 26.5
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title SINGLE FAMILY DWELLING
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 21-0030
Review Notes
12/22/2020 Application pending.
1/6/2021 Point Review - Printed-Online Application
1/6/2021 Point Review - On Hold-Incomplete
1/25/2021 Point Review - Reviewed
1/26/2021 Zoning Review - Documents Required ON HOLD UNTIL SPECIAL FAMILY LOT IS APPROVED
2/2/2021 Plan Review - Documents Required ON HOLD UNTIL SPECIAL FAMILY LOT IS APPROVED NEED FULL SET OF ARCHITECTURAL PLANS NEED TRUSS PLANS UPDATED TO 2020
2/3/2021 Plan Review - Documents Required ON HOLD UNTIL SPECIAL FAMILY LOT IS APPROVED NEED FULL SET OF ARCHITECTURAL PLANS NEED TRUSS PLANS UPDATED TO 2020 RECEIVED ARCHITECTURAL 2-2-21
2/4/2021 Plan Review - Reviewed ON HOLD UNTIL SPECIAL FAMILY LOT IS APPROVED NEED FULL SET OF ARCHITECTURAL PLANS NEED TRUSS PLANS UPDATED TO 2020 REC'D 2/3/2021 RECEIVED ARCHITECTURAL 2-2-21 RECEIVED TRUSS PLANS 2-4-21
2/5/2021 Zoning Review - Reviewed NEED FULL SET OF ARCHITECTURAL PLANS NEED TRUSS PLANS UPDATED TO 2020 REC'D 2/3/2021 RECEIVED ARCHITECTURAL 2-2-21 RECEIVED TRUSS PLANS 2-4-21
2/5/2021 Final Review - Payment Needed NEED FULL SET OF ARCHITECTURAL PLANS NEED TRUSS PLANS UPDATED TO 2020 REC'D 2/3/2021 RECEIVED ARCHITECTURAL 2-2-21 RECEIVED TRUSS PLANS 2-4-21
2/8/2021 Permit Issued Permit #000041275 created and approved.
11/23/2021 Final Review - Payment Needed NEED FULL SET OF ARCHITECTURAL PLANS NEED TRUSS PLANS UPDATED TO 2020 REC'D 2/3/2021 RECEIVED ARCHITECTURAL 2-2-21 RECEIVED TRUSS PLANS 2-4-21
Contractors
Name/ Business License Title Role
Blake Lunde Ii
Blake Construction Company Of North Florida Inc
Liability Insurance Expired.
CBC1253408 Building Contractor Contractor
Aaron Hokanson
Aaron's Plumbing Corporation
Liability Insurance Expired.
CFC1426264 Plumbing Contractor Subcontractor
Blake N Lunde Ii
Blake Roofing Inc
Liability Insurance Expired.
CCC1331699 Cert. Roofing Subcontractor
Matthew H Burns
Burns Electrical Services Inc
EC13006531 Electrical Contractor Subcontractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Matt Forsyth 2/18/2021
Release to power company Matt Forsyth 2/18/2021
Passed: Building - Footer Matt Forsyth 3/4/2021
Passed: Engineering - Setbacks Matt Forsyth 3/4/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 3/22/2021
Passed: Building - Slab Troy Crews 4/1/2021
Failed: Building - Roof Decking All Nails Missing Framing Members Need To Be Removed Matt Forsyth 4/30/2021
Failed: Building - Wall Sheathing All Nails Missing Framing Members Need To Be Removed Matt Forsyth 4/30/2021
Passed: Building - Roof Decking Matt Forsyth 6/11/2021
Passed: Building - Wall Sheathing Matt Forsyth 6/11/2021
Failed: Building - Framing Need Proper Strapping On Porch Post To Header: Matt Forsyth 6/11/2021
Passed: Electrical - 2nd Rough-In Matt Forsyth 6/11/2021
Failed: Mechanical - Rough In Bathroom Exhaust Vet Not Complete Matt Forsyth 6/11/2021
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 6/11/2021
Passed: Building - Framing Matt Forsyth 6/11/2021
Passed: Mechanical - Rough In Matt Forsyth 6/11/2021
Passed: Building - Insulation Walls Vaulted Ceilings Only Matt Forsyth 6/24/2021
Passed: Electrical - Permanent Power Need Septic Release Matt Forsyth 11/24/2021
Release to power company Melissa Garber 11/30/2021
Septic Release Inspection Health Dept 11/30/2021
Passed: Building - Final Matt Forsyth 12/17/2021
Documents