Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 794 SW MANDIBA DR
LAKE CITY, FL 32024
Parcel #: 09280-176
Acres: 0.99
Owner: Gary Reiter
Subdivision: Oaks Of Lake City Phase 2
Zoning: PRRD
Flood Zone: X
District: 5
Application #: 47487
Permit #: 000040842
Related Permit: Culvert: 000040843
Submitted: Wednesday, October 21, 2020
Issued: Wednesday, November 4, 2020
Expires: Monday, July 12, 2021
Completed: Monday, July 12, 2021
Status: Completed
Septic Release? Yes
Notes:
SURVEYOR FINISHED FLOOR ELEVATION LETTER REC'D AT 91.50'
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2132
Total Area (Sqft) 3696
Stories 1
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 20-0824
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Elevation regulation Subdivision Plat
Finished floor requirement 91'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0395C
In floodway N
Review Notes
10/12/2020 Application pending.
10/21/2020 Point Review - Printed-Online Application
10/27/2020 Plan Review - Documents Required
10/30/2020 Plan Review - Reviewed
10/30/2020 Zoning Review - Reviewed
10/30/2020 Final Review - Documents Required
11/3/2020 Final Review - Payment Needed
11/4/2020 Permit Issued Permit #000040842 created and approved.
5/11/2021 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Bryan Zecher
Bryan Zecher Construction Inc
CBC054575 Cert.building Contractor Contractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Anthony R Franks
Franks & Lane Heating And Air Llc
CAC1818631 Cert. A/c Class “b” Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Robert Ogles Ii
Ogles Roofing & Construction Llc
CCC1328699 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 11/4/2020
Passed: Building - Footer Troy Crews 11/30/2020
Passed: Engineering - Setbacks Troy Crews 11/30/2020
Passed: Electrical - Temporary Service Troy Crews 11/30/2020
Release to power company Troy Crews 11/30/2020
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 12/28/2020
Passed: Building - Slab Troy Crews 1/5/2021
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 2/11/2021
Passed: Building - Roof Decking Troy Crews 2/11/2021
Passed: Building - Framing Troy Crews 2/16/2021
Passed: Electrical - 2nd Rough-In Troy Crews 3/4/2021
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 3/4/2021
Passed: Mechanical - Rough In Troy Crews 3/4/2021
Passed: Building - Insulation Need Elevation Confirmation Letter Troy Crews 3/12/2021
Passed: Building - Lath/Stucco Troy Crews 3/18/2021
Passed: Electrical - Permanent Power Need Septic And Drive Final Troy Crews 5/12/2021
Passed: Engineering - Final Driveway Mccormick, David 5/17/2021
Septic Release Inspection Health Dept 5/20/2021
Release to power company Laurie Hodson 5/26/2021
Passed: Building - Final Need Final Termite Cert. For Release Troy Crews 7/9/2021
Certificate-Release Certificate Troy Crews 7/12/2021
Documents
File Name Date File Size
Architectural Plans 20201013 093234.pdf 2023.12.26 1.28MB
Approved Structural Plans 47487 2020-10-30 09.06.04.131.pdf 2023.12.26 19.83MB
Property Appraiser Parcel Details Printed Page 20201013 093236.pdf 2023.12.26 152.30kB
Power Release-electrical-temporary Service 20201130.pdf 2023.12.26 38.86kB
Approved Trusses 47487 2020-10-27 14.17.52.713.pdf 2023.12.26 2.59MB
Win_20210105_15_45_32_pro 2021-01-05 15.47.13.674.jpg 2023.12.26 202.86kB
Energy Code Forms 20201021 084402.pdf 2023.12.26 576.63kB
Truss Engineering 20201013 093236.pdf 2023.12.26 2.46MB
Recorded Deed 20201021 091748.pdf 2023.12.26 460.05kB
Oaks_of_lake_city_phs2 Lot 76 2020-10-30 17.01.36.388.pdf 2023.12.26 4.36MB
Septic Approval Paperwork 20201103 150328.pdf 2023.12.26 625.96kB
Owner And Contractor Signature Page 20201014 105449.pdf 2023.12.26 656.90kB
Original Permit 20201104.pdf 2023.12.26 42.75kB
Site Plan 20201013 093236.pdf 2023.12.26 1.60MB
Backup Material 20201030 050748.pdf 2023.12.26 230.27kB
Recorded Notice Of Commencement 20201021 092001.pdf 2023.12.26 287.29kB
911 Address Form 20201015 162339.pdf 2023.12.26 81.79kB
Residential Or Commercial Checklist 20201013 154809.pdf 2023.12.26 2.72MB
Structural Engineering And Wind Load Calculations 20201029 142226.pdf 2023.12.26 4.53MB
Surveyor Letter Giving The Finished Floor Elevation 20210315 051547.pdf 2023.12.26 158.88kB
Certificate Of Occupancy 20210712.pdf 2023.12.26 54.49kB
Manual J Forms 20201021 084404.pdf 2023.12.26 576.63kB
Power Release-release To Power Company 20210526.pdf 2023.12.26 39.00kB
Subcontractor Form 20201013 094302.pdf 2023.12.26 532.38kB
Reiter Termite 2021-07-12 14.47.35.233.jpeg 2023.12.26 1.23MB
Product Approval Code Specifications Form 20201013 093235.pdf 2023.12.26 502.79kB