Inspection |
Notes |
Performed By |
Date |
Passed: Building - Footer |
Need To Make Sure Lot Does Not Have Set Floor Elevation |
Troy Crews |
11/12/2020 |
Passed: Engineering - Setbacks |
|
Troy Crews |
11/12/2020 |
Rescheduled 12/4/2020:Plumbing/Gas - 1st Underground Rough–In |
|
Troy Crews |
12/3/2020 |
Passed: Plumbing/Gas - 1st Underground Rough–In |
Ac Chase Line Over 50 Feet Suction Line Will Need To Be Upsized, Also Put Fall On Dryer Line To Outside
|
Troy Crews |
12/4/2020 |
Passed: Building - Slab |
Confirm 12 Inch Above Rd. |
Troy Crews |
12/9/2020 |
Passed: Electrical - Temporary Service |
|
Troy Crews |
12/29/2020 |
Release to power company |
|
Troy Crews |
12/29/2020 |
Passed: Building - Roof Decking |
|
Troy Crews |
2/3/2021 |
Passed: Building - Wall Sheathing |
|
Troy Crews |
2/3/2021 |
Failed: Building - Framing |
Need Two King Studs All Openings Over 6ft., Missing Heavy Tie Downs At Garage Opening, Also Need Elevation/engineer Letter |
Troy Crews |
2/5/2021 |
Failed: Building - Insulation |
Requested By Builder, Need Framing Inspection Done That Failed, Also Need Electric, Plumbing, And H.v.a.c. Inspections Passed Prior To Insulation May Have To Be Pulled Out In Areas. |
Troy Crews |
4/8/2021 |
Passed: Electrical - 2nd Rough-In |
|
Anthony Aslan |
4/9/2021 |
Passed: Plumbing/Gas - 2nd Rough-In |
|
Anthony Aslan |
4/9/2021 |
Failed: Building - Framing |
Insulation Covering Anchors Could Not Verify. Truss T11g Could Not Verify Engineering, Spray Foam Insulation Encapsulated. Truss T12 Has Inadequate Strapping For Uplift, Also Could Not Verify Truss Strapping On Porches. Could Not Verify Outlooker Strapping Encapsulated In Spray Foam Insulation |
Anthony Aslan |
4/9/2021 |
Failed: Mechanical - Rough In |
Could Not Verify Kitchen Exhaust Exiting Termination, Kitchen Hood Vent Needs 3 Screws At Joints Of Pipe. Need To Add Straps To Duct Flex. Return Mixing Box Knocked Off Support. |
Anthony Aslan |
4/9/2021 |
Passed: Mechanical - Rough In |
Made Corrections |
Anthony Aslan |
4/15/2021 |
Failed: Building - Framing |
Truss No Strapped. See Notes On Previous Inspection. |
Anthony Aslan |
4/15/2021 |
Passed: Building - Insulation |
|
Anthony Aslan |
4/15/2021 |
Septic Release Inspection |
|
Health Dept |
6/2/2021 |
Failed: Electrical - Permanent Power |
No Front Door |
Anthony Aslan |
6/23/2021 |
Passed: Electrical - Permanent Power |
Rec'd Pictures |
Anthony Aslan |
6/25/2021 |
Passed: Engineering - Initial Driveway |
|
Mccormick, David |
7/2/2021 |
Release to power company |
Culvert Has Been Finaled 7.12.21 By D.mccormick |
Laurie Hodson |
7/9/2021 |
Passed: Engineering - Final Driveway |
|
Mccormick, David |
7/12/2021 |
Passed: Electrical - Permanent Power |
Changed Out To Fpl Approved Can |
Troy Crews |
7/12/2021 |
Release to power company |
|
Troy Crews |
7/12/2021 |
Cancelled: Building - Final |
|
Anthony Aslan |
7/20/2021 |
Failed: Building - Final |
1) A/c Condenser Pad Covered By Mulch
2) Back Porch Outlet Has Open Ground Not Tripping Gfci
3) Bath By Garage Door Gfci Reversed Hot & Neutral
4) Disposal Under Kitchen Sink Gfci Open Ground
5) Kitchen Exhaust No Discharge Grill |
Anthony Aslan |
7/22/2021 |
Passed: Building - Framing |
Items Corrected Per Builder |
Troy Crews |
7/22/2021 |
Failed: Building - Final |
M1503.1general.
range Hoods Shall Discharge To The Outdoors Through A Duct. The Duct Serving The Hood Shall Have A Smooth Interior Surface, Shall Be Air Tight, Shall Be Equipped With A Back-draft Damper And Shall Be Independent Of All Other Exhaust Systems. Ducts Serving Range Hoods Shall Not Terminate In An Attic Or Crawl Space Or Areas Inside The Building.
exception: Where Installed In Accordance With The Manufacturer’s Instructions, And Where Mechanical Or Natural Ventilation Is Otherwise Provided, Listed And Labeled Ductless Range Hoods Shall Not Be Required To Discharge To The Outdoors.
m1305.1.4.1ground Clearance.
equipment And Appliances Supported From The Ground Shall Be Level And Firmly Supported On A Concrete Slab Or Other Approved Material Extending Not Less Than 3 Inches (76 Mm) Above The Adjoining Ground. Such Support Shall Be In Accordance With The Manufacturer’s Installation Instructions. Appliances Suspended From The Floor Shall Have A Clearance Of Not Less Than 6 Inches (152 Mm) From The Ground.
r318.5protection Against Decay And Termites.
condensate Lines, Irrigation/sprinkler System Risers For Spray Heads, And Roof Downspouts Shall Discharge At Least 1 Foot (305 Mm) Away From The Structure Sidewall, Whether By Underground Piping, Tail Extensions Or Splash Blocks. Gutters With Downspouts Are Required On All Buildings With Eaves Of Less Than 6 Inches (152 Mm) Horizontal Projection Except For Gable End Rakes Or On A Roof Above Another Roof. |
Anthony Aslan |
7/23/2021 |
Passed: Building - Final |
Corrections Made |
Anthony Aslan |
7/27/2021 |