Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 894 SE GABE ST
LAKE CITY, FL 32025
Parcel #: 09205-004
Acres: 58.35
Owner: Stalvey Brandon R
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 46226
Permit #: 000039946
Related Permit: Culvert: 000039882
Submitted:
Issued: Monday, June 15, 2020
Expires: Thursday, June 10, 2021
Completed: Thursday, June 10, 2021
Status: Completed
Septic Release? Yes
Notes:
EXISTING MOBILE HOME REMOVED FROM THE PROPERTY PER CONTRACTOR
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0405C
This is the construction of a Single Family Dwelling
Stories 1
Heated Area (Sqft) 2370
Total Area (Sqft) 3685
Building Height 23
Septic# (00-0000) or (X00-000) 20-0395
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Review Notes
5/13/2020 Application pending.
5/15/2020 Point Review - Processing
5/29/2020 Zoning Review - On Hold-Incomplete
5/29/2020 Zoning Review - Email Sent
6/1/2020 Plan Review - Documents Required
6/2/2020 Plan Review - Reviewed
6/2/2020 Final Review - Documents Required
6/15/2020 Permit Issued Permit #000039946 created and approved.
Contractors
Name/ Business License Title Role
Isaiah Cully
Ic Construction Llc
CBC1259655 Building Contractor Contractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Subcontractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Final Driveway Mccormick, David 6/16/2020
Passed: Electrical - Temporary Service No Structural Inspections Until Noc Is Received Troy Crews 8/5/2020
Release to power company Troy Crews 8/5/2020
Passed: Building - Footer Reminder Install Ground Wire On Footer Steel Troy Crews 9/4/2020
Passed: Engineering - Setbacks Troy Crews 9/4/2020
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 9/23/2020
Passed: Building - Slab Troy Crews 9/28/2020
Passed: Building - Roof Decking Troy Crews 10/28/2020
Passed: Building - Wall Sheathing Troy Crews 10/28/2020
Passed: Electrical - 2nd Rough-In Troy Crews 12/2/2020
Failed: Plumbing/Gas - 2nd Rough-In Pressure Lost On Water Lines Troy Crews 12/2/2020
Failed: Building - Framing T-08 Truss Needs Additional Strapping Troy Crews 12/2/2020
Failed: Mechanical - Rough In Exhaust Duct For Oven Must Have Smooth Interior , Questions About Approved Tape For Duct Connections, Access To Fresh Air Motor ? Will Send E-mail Need To Meet Duct Insatllers Onsite. Aslo Need Strapping On Bath Fan Ducts. Troy Crews 12/2/2020
Failed: Plumbing/Gas - 2nd Rough-In Pressure Lost On Water Lines Troy Crews 1/20/2021
Passed: Building - Framing Truss Corrected Troy Crews 1/20/2021
Passed: Mechanical - Rough In Items Corrected Troy Crews 1/20/2021
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 1/21/2021
Failed: Engineering - Final Driveway Needs To Get A Culvert Permit. Mccormick, David 4/1/2021
Passed: Engineering - Initial Driveway Mccormick, David 4/6/2021
Passed: Electrical - Permanent Power Need Septic Final Troy Crews 4/23/2021
Passed: Engineering - Final Driveway Mccormick, David 5/4/2021
Septic Release Inspection Need Final Driveway Release Health Dept 5/4/2021
Release to power company Melissa Garber 5/5/2021
Passed: Building - Final Release Pending Letter From Owner Regarding Water Heater L.p. Connection Troy Crews 6/8/2021
Certificate-Release Certificate Troy Crews 6/10/2021
Documents
File Name Date File Size
Power Release-electrical-temporary Service 20200805.pdf 2025.07.05 13.26kB
Original Permit 20200615.pdf 2025.07.05 28.29kB
Certificate Of Occupancy 20210610.pdf 2025.06.23 53.23kB
Fwd_ Gas 2021-06-10 15.15.36.80.pdf 2025.06.22 76.97kB
Fw_ Gas Connection 2021-06-10 15.15.36.345.pdf 2025.06.22 72.35kB
911 Address Form 20200519 045746.pdf 2025.06.22 151.91kB
Manual J Forms 20200514 083835.pdf 2025.06.22 77.48kB
Subcontractor Form 2020-05-29 13.30.00.532.pdf 2025.06.22 783.28kB
Residential Or Commercial Checklist 20200519 090708.pdf 2025.06.22 519.99kB
Property Appraiser Parcel Details Printed Page 20200515 145717.pdf 2025.06.21 161.14kB
Property Appraiser Printout.pdf 2025.06.21 326.71kB
Energy Code Forms 20200529 012246.pdf 2025.06.21 882.20kB
Win_20200928_10_03_54_pro 2020-09-28 10.10.27.244.jpg 2025.06.20 133.02kB
Blower Door 39946 2021-06-08 16.16.02.97.jpg 2025.06.20 981.10kB
Power Release-release To Power Company 20210505.pdf 2021.05.05 38.85kB
Recorded Noc 39946 2020-09-02 16.47.23.61.pdf 2020.09.02 78.62kB
Septic Approval Paperwork 20200604 094608.pdf 2020.06.04 634.10kB
Architectural Plans 20200601 143323.pdf 2020.06.01 690.20kB
Architectural Plans 20200601 143308.pdf 2020.06.01 1.53MB
Architectural Plans 20200601 143254.pdf 2020.06.01 918.87kB
Architectural Plans 20200601 143238.pdf 2020.06.01 733.88kB
Approved Plans 46226 2020-06-01 08.14.47.694.pdf 2020.06.01 995.52kB
Product Approval Code Specifications Form 20200515 145716.pdf 2020.05.15 732.76kB
Truss Engineering 20200515 081341.pdf 2020.05.15 1,021.22kB
Site Plan 20200514 083835.pdf 2020.05.14 73.37kB
Set Of Unsealed Plans.pdf 2020.05.14 4.94MB
Owner And Contractor Signature Page 20200514 082641.pdf 2020.05.14 1.14MB