Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Culvert Permit

Address 764 SW HEFLIN AVE
FORT WHITE, FL 32038
Parcel #: 10058-676
Acres: 2.43
Owner: Marrero Hector & Robles Iris
Subdivision: Santa Fe River Plantations Replat Of Lots 38,45,46
Zoning: A-3
Flood Zone: X
District: 2
Application #: 50292
Permit #: 000042611
Related Permit: New Residential Construction: 000042610
Submitted: Tuesday, August 17, 2021
Issued: Tuesday, August 24, 2021
Expires: Monday, January 10, 2022
Completed: Monday, January 10, 2022
Status: Completed
Septic Release? na
Notes:
ENGINEER ELEVATION LETTER ON FILE SUBMITTED 8.12.21
Job Details
Finished floor requirement 65.40'
Fema map number 12023C0532C
In floodway N
Building Permit # 000042610
Standards Shall conform to Public Works Determinations as stated below
Requirements Install min, 32 ' × 12" corr metal culvert w / concrete mitred ends, w / 6 " × 6 " welded wire, rebar or culvert bolts in mitred ends , concrete mitred ends W - 4ft x L - 5ft, and with 4 inches of limerock on top cover. Changed from 18inch to 12inch pipe after speaking with home owner
Status Approved
Review Notes
8/24/2021 Permit Issued Permit #000042611 created and approved.
Contractors
Name/ Business License Title Role
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 8/24/2021
Passed: Engineering - Initial Driveway Blake Requested It To Be Resent To Make Corrections To What The Requirements Need To Be Smith, Blake 12/15/2021
Failed: Engineering - Final Driveway Mitered Ends Were Not Poured. Jones, Richard 12/22/2021
Passed: Engineering - Final Driveway Smith, Blake 1/10/2022
Documents
File Name Date File Size