Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 764 SW HEFLIN AVE
FORT WHITE, FL 32038
Parcel #: 10058-676
Acres: 2.43
Owner: Marrero Hector & Robles Iris
Subdivision: Santa Fe River Plantations Replat Of Lots 38,45,46
Zoning: A-3
Flood Zone: X
District: 2
Application #: 49849
Permit #: 000042610
Related Permit: Culvert: 000042611
Submitted: Sunday, July 18, 2021
Issued: Tuesday, August 24, 2021
Expires: Monday, March 7, 2022
Completed: Monday, March 7, 2022
Status: Completed
Septic Release? Yes
Notes:
ENGINEER ELEVATION LETTER ON FILE SUBMITTED 8.12.21
Job Details
Elevation regulation Engineers Elevation Letter
Finished floor requirement 65.40'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0532C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 50
Setback Side 1 50
Setback Side 2 50
Setbacks Rear 50
Stories 1
Heated Area (Sqft) 1407
Total Area (Sqft) 2213
Building Height 21.66
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Septic# (00-0000) or (X00-000) 21-0608
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
7/7/2021 Application pending.
7/19/2021 Point Review - Printed-Online Application NEEDED: ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
7/28/2021 Zoning Review - Reviewed CORY: CURRENT COPY OF CERTIFICATE OF LIABILITY ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
8/5/2021 Plan Review - Plumbing Approved ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
8/5/2021 Plan Review - Mechanical Approved ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
8/5/2021 Plan Review - Electrical Approved ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
8/5/2021 Plan Review - Building Approved ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
8/5/2021 Plan Review - Reviewed ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
8/5/2021 Zoning Review - Reviewed ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
8/5/2021 Final Review - Documents Required ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
8/12/2021 Zoning Review - Reviewed ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL-- CONTACT 386-758-105
8/17/2021 Final Review - Payment Needed
8/24/2021 Permit Issued Permit #000042610 created and approved.
1/3/2022 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Corey J Amira
Amira Custom Homes, Inc.
Workers Comp Expired.
CRC1331309 Cert. Residential Contractor
James Butler Jr
Butler Plumbing Of Gainesville Inc
CFC057960 Plumbing Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Ryan C Beville
Rbi Electrical Contracting Llc
Employees Workers Comp Expired.
EC13004236 Electrical Contractor Subcontractor
Robert M Bounds
Bounds Heating & Air Inc
CAC057642 Class A A/c Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 8/24/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 8/25/2021
Passed: Building - Monolithic Slab Anthony Aslan 9/8/2021
Passed: Engineering - Setbacks Anthony Aslan 9/8/2021
Cancelled: Building - Monolithic Slab Troy Crews 9/10/2021
Cancelled: Engineering - Setbacks Troy Crews 9/10/2021
Cancelled: Electrical - 1st Underground Rough–In Troy Crews 9/10/2021
Passed: Electrical - Temporary Service Troy Crews 9/10/2021
Release to power company Troy Crews 9/10/2021
Cancelled: Building - Ext Strapping/Wall Sheathing Anthony Aslan 9/24/2021
Passed: Building - Ext Strapping/Wall Sheathing Anthony Aslan 9/27/2021
Passed: Building - Roof Decking Anthony Aslan 9/27/2021
Passed: Building - Framing Anthony Aslan 10/14/2021
Passed: Building - Strapping Anthony Aslan 10/14/2021
Passed: Electrical - 2nd Rough-In Anthony Aslan 10/14/2021
Passed: Mechanical - Rough In Anthony Aslan 10/14/2021
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 10/14/2021
Passed: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 10/14/2021
Passed: Building - Insulation Anthony Aslan 10/29/2021
Passed: Engineering - Initial Driveway Blake Requested It To Be Resent To Make Corrections To What The Requirements Need To Be Smith, Blake 12/15/2021
Failed: Engineering - Final Driveway Mitered Ends Were Not Poured. Jones, Richard 12/22/2021
Passed: Electrical - Permanent Power Need Septic Release And Driveway Release Anthony Aslan 1/4/2022
Passed: Engineering - Final Driveway Smith, Blake 1/10/2022
Passed: Building - Final Anthony Aslan 3/1/2022
Release to power company Septic Rec'd-- Will Run Report On Monday Melissa Garber 3/4/2022
Certificate-Release Certificate Rec'd Docs Anthony Aslan 3/7/2022
Septic Release Inspection Health Dept 3/7/2022
Documents
File Name Date File Size
Hs3zppnq.3op.pdf 2025.07.14 609.02kB
B4014bhi.v1q.pdf 2025.07.14 698.58kB
Power Release-electrical-temporary Service 20210910.pdf 2025.07.05 11.35kB
Original Permit 20210824.pdf 2025.07.05 28.39kB
Lidar 49849 2021-07-28 11.46.38.348.pdf 2025.07.05 108.73kB
Marrero Foundation Survey 42610 2021-09-22 17.45.39.196.pdf 2025.07.05 136.96kB
Property Appraiser Parcel Details Printed Page 20210711 192647.pdf 2025.07.05 140.48kB
Architectural Plans Page 2.pdf 2025.07.05 182.32kB
911 Address Form 20210711 191644.pdf 2025.07.05 109.52kB
Bnz Invoice 2021-08-17.pdf 2025.07.05 184.33kB
Septic Approval Paperwork 20210817 043548.pdf 2025.07.05 381.12kB
Architectural Plans Page 3.pdf 2025.07.05 580.82kB
Architectural Plans Page 1.pdf 2025.07.05 650.86kB
Elevation Letter 764 Sw Heflin Avenue Fort White Fl 08-12-21 2021-08-12 17.24.39.130.pdf 2025.07.04 1.08MB
Site Plan 20210711 193937.pdf 2025.07.04 307.20kB
Structural Engineering And Wind Load Calculations 20210711 192825.pdf 2025.07.04 3.25MB
Approved Structural 49849 2021-08-05 09.28.28.952.pdf 2025.07.04 3.28MB
Owner And Contractor Signature Page 20210711 191456.pdf 2025.07.04 1,009.35kB
Residential Or Commercial Checklist 20210711 193843.pdf 2025.07.04 4.05MB
Energy Code Forms.pdf 2025.06.23 48.32kB
Truss Layout.pdf 2025.06.22 275.42kB
Application Information Page.pdf 2025.06.21 390.32kB
Blower Door.pdf 2025.06.20 1.30MB
Compaction Test 2021-09-08 12.36.49.65.jpg 2025.06.20 170.28kB
Termite Initial 2021-09-08 12.36.57.96.jpg 2025.06.20 181.69kB
Certificate Of Occupancy 20220307.pdf 2023.12.23 62.23kB
Manual J Forms 20210711 191902.pdf 2023.12.23 150.65kB
Marrero Noc 2021-08-24 13.04.57.456.pdf 2023.12.23 99.77kB
Recorded Deed 20210711 192709.pdf 2023.12.23 66.19kB
Final Termite.pdf 2022.03.07 75.61kB
Power Release-release To Power Company 20220304.pdf 2022.03.04 38.96kB
New Well Letter.pdf 2021.07.11 137.51kB