Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 329 SW COLONY GLN
LAKE CITY, FL 32024
Parcel #: 03761-141
Acres: 5.01
Owner: Kramer Ronald Francis & Karen
Subdivision: Meadowlands Phase 3
Zoning: A-3
Flood Zone: X
District: 4
Application #: 47496
Permit #: 000040884
Related Permit: Culvert: 000041929
Submitted:
Issued: Friday, November 13, 2020
Expires: Friday, June 25, 2021
Completed: Friday, June 25, 2021
Status: Completed
Septic Release? Yes
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0381D
This is the construction of a SFD/UTILITY
Setbacks Front 25.00
Setback Side 1 10.00
Setback Side 2 10.00
Setbacks Rear 15.00
Stories 1
Heated Area (Sqft) 1630.00
Total Area (Sqft) 2354.00
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 18-0092
Review Notes
10/12/2020 Point Review - Received-Hard Copy Application
10/12/2020 Point Review - Reviewed
10/14/2020 Zoning Review - Reviewed
10/19/2020 Plan Review - Documents Required
10/22/2020 Zoning Review - Reviewed
10/27/2020 Plan Review - Documents Required
11/12/2020 Plan Review - Reviewed
11/12/2020 Final Review - Payment Needed
11/13/2020 Permit Issued
Contractors
Name/ Business License Title Role
Mark J Mashburn
America's Home Place Inc
CRC1330787 Residential Contractor Contractor
Joseph H Strada Jr
Strada Electric & Security
EC13003715 Cert Electrical Subcontractor
Timothy D Shatto
Shatto Heating & Air, Inc.
CAC057875 A/c Class B Subcontractor
Travis L Timmons
Worthmann Llc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CCC1330501 Cert. Roofing Subcontractor
Nate D Bazinet
Sunshine Plumbing & Gas
County License & State License & Liability Insurance & Workers Comp Expired.
CFC1427687 Plumbing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 11/16/2020
Passed: Building - Footer Troy Crews 11/20/2020
Passed: Engineering - Setbacks Troy Crews 11/20/2020
Passed: Building - Slab Troy Crews 11/20/2020
Passed: Building - Wall Sheathing Troy Crews 1/5/2021
Passed: Building - Roof Decking Troy Crews 1/5/2021
Passed: Building - Framing Troy Crews 2/10/2021
Passed: Electrical - 2nd Rough-In Troy Crews 2/10/2021
Failed: Plumbing/Gas - 2nd Rough-In Not Complete Nail Plates, Pressure On Lines, Shower Valve Etc. Troy Crews 2/10/2021
Passed: Mechanical - Rough In Reminder Will Need Notice On Electric Panel For Air Handler In Attic Troy Crews 2/10/2021
Passed: Building - Insulation Troy Crews 3/1/2021
Passed: Plumbing/Gas - 2nd Rough-In Items Corrected Troy Crews 3/1/2021
Failed: Electrical - Temporary Service Need Elevation Confirmation Letter From Surveyor, Need Septic Final From Health Dept., Need Final Inspection On Culvert From Public Works. Troy Crews 3/24/2021
Passed: Engineering - Initial Driveway Mccormick, David 5/18/2021
Septic Release Inspection Health Dept 6/4/2021
Failed: Electrical - Temporary Service You Are Trying To Get Permanent Power, Need Driveway Inspection By Public Works, And Engineering Letter For Floor Elevation Approved Troy Crews 6/7/2021
Release to power company Laurie Hodson 6/8/2021
Passed: Engineering - Final Driveway Mccormick, David 6/8/2021
Passed: Electrical - Permanent Power Need Final On Culvert Inspection For Release Troy Crews 6/8/2021
Failed: Building - Final Need Air Handler Notice On Electric Panel Send Picture Of It Installed. Troy Crews 6/24/2021
Passed: Building - Final Decal Installed For Air Handler Troy Crews 6/25/2021
Documents
File Name Date File Size