Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Culvert Permit

Address 327 SW WHITETAIL CIR
LAKE CITY, FL 32024
Parcel #: 02732-560
Acres: 0.33
Owner: Adam Chapital & Shawn Thomas
Subdivision: Deer Creek Phase 3
Zoning: RSF/MH-3
Flood Zone: X
District: 3
Application #: 44231
Permit #: 000039071
Related Permit: Mobile Home: 000039070
Submitted: Friday, December 20, 2019
Issued: Friday, December 20, 2019
Expires: Tuesday, January 21, 2020
Completed: Tuesday, January 21, 2020
Status: Completed
Septic Release? na
Notes:
MUST STRING FRONT SETBACK LINE FOR INSPECTION, MINIMUM FLOOR ELEVATION - 1 FOOT ABOVE THE ROAD
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 104.75'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0289D
This is the construction of a Single Family Dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Stories 1
Heated Area (Sqft) 1941
Total Area (Sqft) 2880
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title SINGLE FAMILY DWELLING
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Septic# (00-0000) or (X00-000) 25-0535
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps 200
Review Notes
12/20/2019 Permit Issued
Contractors
Name/ Business License Title Role
Brent M Strickland

IH1104218 Mh Installer (ih) Contractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 12/23/2019