Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 1682 SW SALEM RD
LAKE CITY, FL 32024
Parcel #: 03062-205
Acres: 22.48
Owner: Curtis & Daphne Sistruck
Subdivision: Sun Park Woods Unrec
Zoning: AG-3
Flood Zone: X
District: 2
Application #: 39984
Permit #: 000037529
Related Permit: Culvert Waiver: 000002713
Submitted: Tuesday, December 11, 2018
Issued: Tuesday, December 11, 2018
Expires: Friday, June 21, 2019
Completed: Friday, June 21, 2019
Status: Completed
Septic Release? Yes
Notes:
FLOOR ONE FOOT ABOVE THE ROAD, NOC ON FILE
Job Details
This is the construction of a SFD, UTILITY
Heated Area (Sqft) 1632.00
Total Area (Sqft) 2634.00
Stories 1
Setbacks Front 30.00
Setback Side 1 25.00
Setback Side 2 25.00
Setbacks Rear 25.00
Septic# 18-0908
Power Company Clay Elec.
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Fema map number 12023C0270C
Review Notes
Contractors
Name/ Business License Title Role
Blake Lunde

CBC1253408
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Troy Crews 12/14/2018
Passed: Engineering - Setbacks Troy Crews 12/14/2018
Passed: Plumbing/Gas - Underground Rough-In Troy Crews 1/2/2019
Failed: Building - Slab Missed Interior Footers Will Need Termite Spray Touched Up Troy Crews 1/7/2019
Passed: Building - Slab Troy Crews 1/8/2019
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 2/7/2019
Passed: Building - Roof Decking Troy Crews 2/7/2019
Failed: Building - Framing Header Over Master Shower Calls For 3 2x12 Has 2 Call Back In With Insulation Inspection Troy Crews 2/27/2019
Passed: Electrical - Rough In Troy Crews 2/27/2019
Passed: Mechanical - Rough In Troy Crews 2/27/2019
Passed: Plumbing/Gas - Rough In Troy Crews 2/27/2019
Passed: Building - Framing Beam Installed Troy Crews 3/27/2019
Passed: Building - Insulation Troy Crews 3/27/2019
Passed: Electrical - Permanent Power Need Health Release Troy Crews 5/23/2019
Release to power company Lh 5/30/2019
Septic Release Inspection Health Dept 5/30/2019
Release to power company Resent To Clay.... Contractor Marked Fpl On application When Permit Was Issued. Tc 6/7/2019
Failed: Building - Final Outside Receptacles Not On Gfci Troy Crews 6/18/2019
Passed: Building - Final Outside Gfci Installed Picture In File Troy Crews 6/19/2019
Documents
File Name Date File Size
Certificate Of Occupancy 20190621.pdf 2023.12.26 50.56kB
Permit-000037529.pdf 2023.12.26 52.45kB