Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 1361 SW WILSON SPRINGS RD
FORT WHITE, FL 32038
Parcel #: 04018-004
Acres: 20.05
Owner: Richard & Anita Auchter
Subdivision:
Zoning: AG-3
Flood Zone: X
District: 2
Application #: 39827
Permit #: 000037411
Related Permit: Culvert Waiver: 000002694
Submitted: Tuesday, November 6, 2018
Issued: Tuesday, November 6, 2018
Expires: Thursday, May 23, 2019
Completed: Thursday, May 23, 2019
Status: Completed
Septic Release? Yes
Notes:
FLOOR ONE FOOT ABOVE THE ROAD, NOC ON FILE
Job Details
This is the construction of a SFD, UTILITY
Heated Area (Sqft) 1995.00
Total Area (Sqft) 4812.00
Stories 2
Setbacks Front 30.00
Setback Side 1 25.00
Setback Side 2 25.00
Setbacks Rear 25.00
Septic# 18-0840
Power Company CLAY
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Fema map number 12023C0490C
Review Notes
Contractors
Name/ Business License Title Role
Jeff Gutapfel

County License & State License & Liability Insurance & Workers Comp Expired.
CBC060248
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Tommy Matthews 11/30/2018
Passed: Engineering - Setbacks Tommy Matthews 11/30/2018
Passed: Building - Slab Tommy Matthews 11/30/2018
Passed: Building - Vertical Cells/Columns Troy Crews 12/6/2018
Passed: Building - Lintel/Tie Beam Troy Crews 12/6/2018
Passed: Electrical - Temporary Service Troy Crews 12/14/2018
Release to power company Troy Crews 12/14/2018
Passed: Building - Framing Tommy Matthews 12/28/2018
Passed: Building - Ext Strapping/Wall Sheathing Tommy Matthews 1/15/2019
Septic Release Inspection Health Dept 2/11/2019
Passed: Electrical - Rough In Tommy Matthews 2/12/2019
Passed: Plumbing/Gas - Rough In Tommy Matthews 2/12/2019
Passed: Mechanical - Rough In Tommy Matthews 2/12/2019
Failed: Building - Framing Plans Not On Site Tommy Matthews 2/12/2019
Passed: Building - Framing Tommy Matthews 2/18/2019
Passed: Building - Insulation Tommy Matthews 2/27/2019
Passed: Electrical - Permanent Power Tommy Matthews 3/26/2019
Release to power company Tommy Matthews 3/26/2019
Passed: Building - Final Tommy Matthews 5/22/2019
Documents
File Name Date File Size
Permit-000037411.pdf 2023.12.26 43.56kB
Sub Contractor Form 2019-01-24 10.38.58 Am.pdf 2023.12.26 83.16kB