Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 341 SW RIDGE ST LAKE CITY FL 32024
Parcel #: 03171-011
Acres: 3.94
Owner: David & Emily Martin
Subdivision: Oak Ridge Estates
Zoning: AG-3
Flood Zone: X
District: 5
Application #: 31858
Permit #: 000035536
Related Permit: Culvert: 000002448
Submitted: Tuesday, July 11, 2017
Issued: Tuesday, July 11, 2017
Expires: Wednesday, April 4, 2018
Completed: Wednesday, April 4, 2018
Status: Completed
Septic Release? Yes
Notes:
FLOOR ONE FOOT ABOVE THE ROAD, NOC ON FILE BLOWER DOOR TEST REQUIRED, ELEVATION LETTER REC'D STATING MFE SHALL BE NO LESS THAN 12" ABOVE NATURAL GRADE AND 6" ABOVE FINISHED GRADE
Job Details
This is the construction of a SFD, UTILITY
Heated Area (Sqft) 2714.00
Total Area (Sqft) 4183.00
Stories 1
Setbacks Front 30.00
Setback Side 1 25.00
Setback Side 2 25.00
Setbacks Rear 25.00
Septic# 17-0403-N
Power Company CLAY
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Fema map number 12023C0381D
Review Notes
Contractors
Name/ Business License Title Role
Blake Lunde
Blake Construction Company Of North Florida Inc
CBC1253408 Building Contractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Dm 7/13/2017
Setback Inspection Randy Jones 7/26/2017
Setback Inspection Randy Jones 7/26/2017
Foundation Inspection Randy Jones 7/28/2017
Temporary Power Inspection Troy Crews 7/28/2017
Foundation Inspection Randy Jones 7/28/2017
Perimeter Beam/Column Inspection Troy Crews 8/8/2017
Underslab Rough Plumbing Inspection Troy Crews 8/16/2017
Slab Inspection Tommy Matthews 8/17/2017
Sheathing and Nailing Inspection Troy Crews 10/3/2017
Framing Inspection Troy Crews 10/27/2017
Rough-In Plumbing Inspection Troy Crews 10/27/2017
Electrical Rough-In Inspection Troy Crews 10/27/2017
Heat and Air Duct Inspection Troy Crews 10/27/2017
Insulation Inspection Troy Crews 11/14/2017
Septic Release Inspection Health Dept 2/22/2018
Failed: Electrical - Permanent Power Need Conduit Installed To Meter Can Troy Crews 2/22/2018
Passed: Electrical - Permanent Power Troy Crews 2/23/2018
Release to power company Laurie Hodson 3/5/2018
Passed: Engineering - Final Driveway Dm 3/5/2018
Passed: Building - Final Troy Crews 4/3/2018
CERTIFICATE OF OCCUPANCY/COMPLETION DATE 4/4/2018
Final Inspection Troy Crews 4/4/2018
(Requested) Framing
(Requested) Above slab Rough-in
(Requested) Electrical Rough-in
(Requested) Heat & AC-
Documents
File Name Date File Size
Certificate Of Occupancy.pdf 2023.12.26 141.08kB
Permit-000035536.pdf 2023.12.26 29.64kB
Permit-35536.pdf 2023.12.26 29.64kB