Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 259 SW GUSTY GLEN LAKE CITY FL 32025
Parcel #: 08944-014
Acres: 11.00
Owner: Trent Giebeig
Subdivision: Hillcrest
Zoning: A-3
Flood Zone: X
District: 4
Application #: 27435
Permit #: 000022056
Related Permit: Culvert: 000000350
Submitted: Thursday, July 8, 2004
Issued: Thursday, July 8, 2004
Expires: Wednesday, November 17, 2004
Completed: Wednesday, November 17, 2004
Status: Completed
Septic Release? No
Notes:
ONE FOOT ABOVE THE ROAD, NOC ON FILE 08/16/2004-Nailing-RK
Job Details
Finished floor requirement
Fema map number 12023C0505C
Type Roofing Job Overlay with Metal
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) structure # 2
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 25
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? Yes
Type of New Roofing Product Metal
Florida Product Approval Number FL 17992.1 R3
Product Manufacturer Capital Metal Supply
Product Description 29 Guage Capital rib panel
Building Code Edition 2020 Florida Building Code 7th Edition and Florida Statute 553.844
Sealed roof decking options: (Must select an option.) Other (explain)
Sealed roof decking explanation for other option. metal over 1x4 Wood Purlins
Ventilation: Powered Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
Contractors
Name/ Business License Title Role
John Norris

RG0066597
Inspections
Inspection Notes Performed By Date
Temporary Power Inspection Randy Jones 7/13/2004
Temporary Power Inspection Randy Jones 7/13/2004
Underslab Rough Plumbing Inspection Randy Jones 7/14/2004
Underslab Rough Plumbing Inspection Randy Jones 7/14/2004
Slab Inspection Randy Jones 7/15/2004
Slab Inspection Randy Jones 7/15/2004
Permanent Power Inspection Richard Keen 11/10/2004
Final Inspection Richard Keen 11/17/2004
CERTIFICATE OF OCCUPANCY/COMPLETION DATE 11/17/2004
Documents