Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 677 SE ROSEWOOD CIR
LAKE CITY, FL 32025
Parcel #: 07592-437
Acres: 0.62
Owner: Pierson Steven,
Subdivision:
Zoning: RMF-1
Flood Zone: X
District: 4
Application #: 71479
Permit #: 000053359
Related Permit:
Submitted: Monday, June 9, 2025
Issued: Thursday, June 12, 2025
Expires: Tuesday, December 9, 2025
Completed:
Status: Permit Issued
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0311D
Type Roofing Job Overlay with Metal
Further Job Details (Explain if decking is being replaced and or Repairs are being done.) Metal over shingles with synthetic felt in between (NO 1X4s)
Type of structure House
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 2300
No. of Stories 1
Roof Pitch 4:12 or Greater
Is the existing roof being removed? No
Type of New Roofing Product Metal
Florida Product Approval Number 42379.02-r2
Product Manufacturer foritfy metals
Product Description residential panels
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) Other (explain)
Sealed roof decking explanation for other option. 1 layer of synthetic felt over 1 layer of existing shingles.
Ventilation: Ridge Vent
Flashing: Replace All
Drip Edge: Replace All
Valley Treatment: New Metal
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
6/9/2025 City of Lake City Utilities Notified. City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
6/10/2025 Final Review - Corrections Needed NEEDED: *BROWN UPDATED LIABILITY-- EMAIL TO INSURANCECERT@COLUMBIACOUNTYFLA.COM
6/12/2025 Final Review - Payment Needed NEEDED:
6/12/2025 Permit Issued Permit #000053359 created and approved.
Contractors
Name/ Business License Title Role
Dennis A Brown
Affordable Roofing Of Central Fl Inc
CCC1327943 Roofing Contractor Contractor
Inspections
Inspection Notes Performed By Date
Failed: Re-Roof - In Progress Product Approval Code Is For 15/32 Plywood Or 3/4 Wood Plank. Need Verification On Substrate Anthony Aslan 6/17/2025