Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 1152 SE MAGNOLIA LOOP
LAKE CITY, FL 32025
Parcel #: 13564-004
Acres: 0.22
Owner: Diy Development Llc,
Subdivision: Woodland Grove Unit 1
Zoning:
Flood Zone: X
District: 5
Application #: 61169
Permit #: 000047837
Related Permit:
Submitted: Friday, May 12, 2023
Issued: Monday, August 7, 2023
Expires: Friday, March 8, 2024
Completed: Friday, March 8, 2024
Status: Completed
Septic Release? Yes
Notes:
ZONING REVIEW COMPLETED BY CITY OF LAKE CITY CONTACT CITY OF LAKE CITY FOR DRIVEWAY PERMIT
LAKE CITY UTLITY CUSTOMER SERVICE NOTES The Utility Department approved a Tap Application for potable water and sanitary sewer services. LAKE CITY ZONING NOTES Access permit received on 06/27 LAKE CITY CODE ENFORCEMENT CASE NOTES None
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1032
Total Area (Sqft) 1306
Stories 1
Building Height 17.11
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Septic# (00-0000) or (X00-000) x-city
Service Amps 200
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Fema map number 12023C0311D
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
5/12/2023 Application pending.
5/12/2023 Application submitted by applicant.
5/12/2023 City of Lake City City of Lake City Notified of Application within City of Lake City LC_GAS, LC_WATER, LC_SEWER.
5/16/2023 Point Review - Reviewed NEEDED * CITY OF LAKE CITY APPROVAL LETTER * ENVIRONMENTAL HEALTH SIGNED SITE PLAN *PRIOR TO INSPECTIONS* RECORDED NOC
5/16/2023 Point Review - Printed-Online Application NEEDED * CITY OF LAKE CITY APPROVAL LETTER * ENVIRONMENTAL HEALTH SIGNED SITE PLAN *PRIOR TO INSPECTIONS* RECORDED NOC
7/3/2023 Point Review - Reviewed *PRIOR TO INSPECTIONS* RECORDED NOC
7/13/2023 Plan Review - Corrections Needed NEEDED **ENERGY FORM NOT SEER2 COMPLAINT * ENVIRONMENTAL HEALTH SIGNED SITE PLAN *PRIOR TO INSPECTIONS* RECORDED NOC
7/24/2023 Plan Review - Corrections Needed NEEDED **ENERGY FORM NOT SEER2 COMPLAINT * ENVIRONMENTAL HEALTH SIGNED SITE PLAN *PRIOR TO INSPECTIONS* RECORDED NOC
7/25/2023 Plan Review - Documents Required NEEDED **MISSING S.2, S.3 ENGINEERING SHEETS **ENERGY FORM NOT SEER2 COMPLAINT (NEED BY FINAL REVIEW) * ENVIRONMENTAL HEALTH SIGNED SITE PLAN *PRIOR TO INSPECTIONS* RECORDED NOC
7/28/2023 Plan Review - Building Approved NEEDED *PRIOR TO INSPECTIONS* RECORDED NOC
7/28/2023 Plan Review - Electrical Approved NEEDED *PRIOR TO INSPECTIONS* RECORDED NOC
7/28/2023 Plan Review - Mechanical Approved NEEDED *PRIOR TO INSPECTIONS* RECORDED NOC
7/28/2023 Plan Review - Plumbing Approved NEEDED *PRIOR TO INSPECTIONS* RECORDED NOC
7/28/2023 Plan Review - Fuel/Gas Approved NEEDED *PRIOR TO INSPECTIONS* RECORDED NOC
7/28/2023 Plan Review - Reviewed NEEDED *PRIOR TO INSPECTIONS* RECORDED NOC
8/4/2023 Zoning Review - Reviewed *PRIOR TO INSPECTIONS* RECORDED NOC
8/4/2023 Final Review - Reviewed *PRIOR TO INSPECTIONS* RECORDED NOC
8/4/2023 Final Review - Payment Needed *PRIOR TO INSPECTIONS* RECORDED NOC
8/7/2023 Permit Issued Permit #000047837 created and approved.
Contractors
Name/ Business License Title Role
Isaiah Cully
Ic Construction Llc
CBC1259655 Building Contractor Contractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Subcontractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 8/28/2023
Failed: Building - Slab Need Compaction Test Anthony Aslan 9/7/2023
Passed: Building - Slab Anthony Aslan 9/11/2023
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 10/9/2023
Passed: Building - Framing Anthony Aslan 11/8/2023
Passed: Electrical - 2nd Rough-In Anthony Aslan 11/8/2023
Passed: Mechanical - Rough In Anthony Aslan 11/8/2023
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 11/8/2023
Passed: Building - Insulation Anthony Aslan 11/29/2023
Passed: Electrical - Temporary Service Anthony Aslan 11/29/2023
Release to power company Anthony Aslan 11/29/2023
Passed: Electrical - Permanent Power Anthony Aslan 2/8/2024
Release to power company Anthony Aslan 2/8/2024
Passed: Building - Final Need Final Termite Anthony Aslan 3/4/2024
Certificate-Release Certificate Received Document Anthony Aslan 3/5/2024
Certificate-Release Certificate Anthony Aslan 3/8/2024
Documents
File Name Date File Size
Certificate Of Occupancy 20240308.pdf 2024.03.08 62.23kB
Termite Certificate_final 20240304 170610.pdf 2024.03.04 277.60kB
Blower Door Test Results 20240304 121947.pdf 2024.03.04 384.39kB
Power Release-electrical-permanent Power 20240208.pdf 2024.02.08 38.97kB
Site Plan 20230512 113229.pdf 2023.12.23 58.21kB
Product Approval Code Specifications Form 20230512 113227.pdf 2023.12.23 96.43kB
Detail By Entity Name 2023-05-16 09.46.16.287.pdf 2023.12.23 137.10kB
Residential Or Commercial Checklist 20230512 113228.pdf 2023.12.23 857.30kB
Recorded Notice Of Commencement 20230808 090408.pdf 2023.12.23 98.72kB
Owner And Contractor Signature Page 20230512 163441.pdf 2023.12.23 734.95kB
Truss Engineering 20230512 113229.pdf 2023.12.23 410.74kB
Manual J Forms 20230725 131154.pdf 2023.12.23 345.22kB
Reviewed Architectural Plans 61169 2023-07-13 14.44.15.926.pdf 2023.12.23 6.57MB
1152 Se Magnolia Loop 2023-05-16 09.53.00.37.pdf 2023.12.23 871.41kB
Reviewed S.3 Structural.pdf 2023.12.23 2.60MB
Recorded Notice Of Commencement 20230714 155321.pdf 2023.12.23 98.72kB
Reviewed S.4 Structural.pdf 2023.12.23 910.65kB
City Of Lake City Approval Letter.pdf 2023.12.23 186.12kB
Original Permit 20230807.pdf 2023.12.23 45.88kB
Other 20230908 100248.pdf 2023.12.23 7.41MB
Reviewed Truss Engineering 61169 2023-07-13 14.44.15.472.pdf 2023.12.23 448.72kB
Subcontractor Form 20230512 113229.pdf 2023.12.23 781.23kB
Reviewed S.1 Structural.pdf 2023.12.23 897.63kB
Architectural Plans 20230512 113225.pdf 2023.12.23 6.53MB
Energy Form Updated.pdf 2023.12.23 52.27kB
Manual J.pdf 2023.12.23 345.21kB
Power Release-electrical-temporary Service 20231129.pdf 2023.12.23 38.83kB
Property Appraiser Parcel Details Printed Page 20230512 113227.pdf 2023.12.23 553.62kB