Roof Replacement or Repair
Permit
| Application #: | 72114 |
| Permit #: |
000053634 |
| Related Permit: |
|
| Submitted: | Wednesday, July 16, 2025 |
| Issued: | Tuesday, July 22, 2025 |
| Expires: | Thursday, September 11, 2025 |
| Completed: | Thursday, September 11, 2025 |
| Status: |
Completed |
| Septic Release? |
N/A |
Job Details
| Finished floor requirement |
|
| Fema map number |
12023C0467C |
| Type Roofing Job |
Partial Roof Repairs |
| Further Job Details (Explain if decking is being replaced and or Repairs are being done.) |
Partial reroof metal roofing system back left gable, replacing 2 metal panels in middle of roof, repair 10 ft section on right side |
| Type of structure |
House |
| Commercial or Residential |
Residential |
| Roof Area (for this job) Sq Ft |
1000 |
| No. of Stories |
2 |
| Roof Pitch |
2:12 to 4:12 |
| Is the existing roof being removed? |
Yes |
| Explain if not removing the existing roofing material? |
Partial reroof, repair section |
| Type of New Roofing Product |
Metal |
| Florida Product Approval Number |
FL 36904.2 |
| Product Manufacturer |
Tri County Metals |
| Product Description |
TCM-LOK |
| Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
| Sealed roof decking options: (Must select an option.) |
Other (explain) |
| Sealed roof decking explanation for other option. |
FL 17401.1 Mid-States QUIK-Stick peel and stick underlayment used only in partial reroof and repair areas |
| Ventilation: |
Off-ridge Vent |
| Flashing: |
Repair Existing |
| Drip Edge: |
Repair Existing |
| Valley Treatment: |
Use Existing |
| Any cable and/or race-way wiring located on or within the roof assembly? |
No |
Review Notes
| 7/16/2025 |
Application pending. |
| 7/18/2025 |
Application submitted by applicant. |
| 7/18/2025 |
Final Review - Payment Needed |
| 7/21/2025 |
Final Review - Complete |
| 7/21/2025 |
Final Review - Corrections Needed |
| 7/22/2025 |
Permit Issued |
Contractors
| Name / Business |
License |
Title |
Role |
Dale Tadlock Tadlock Roofing Inc
Liability Insurance & Workers Comp Expired. |
CCC1335665 |
Cert. Roofing |
Contractor |
Inspections
| Inspection |
Notes |
Performed By |
Date |
| Passed: Re-Roof - In Progress |
Roof Project Is Complete Request Pictures And Affidavit For Final |
Matt Forsyth |
8/1/2025 |
| Failed: Re-Roof - Final |
Reviewing Pictures For Final Inspection It Appears Skylights Are Not Flashed Properly Request More Pictures If Any And Manufacturers Specifications For Installation |
Matt Forsyth |
8/4/2025 |
| Rescheduled 8/29/2025:Re-Roof - Roof Pictures Review |
|
Troy Crews |
8/28/2025 |
| Passed: Re-Roof - Roof Pictures Review |
|
Matt Forsyth |
8/29/2025 |
| Failed: Re-Roof - Final |
No Work Complete |
Matt Forsyth |
9/3/2025 |
| Passed: Re-Roof - Final |
|
Matt Forsyth |
9/10/2025 |