New Residential Construction
Permit
| Application #: | 74549 |
| Permit #: |
000054839 |
| Related Permit: |
|
| Submitted: | Monday, January 12, 2026 |
| Issued: | Wednesday, June 3, 2026 |
| Expires: | Monday, November 30, 2026 |
| Completed: | |
| Status: |
Permit Reissued |
| Septic Release? |
No |
Job Details
| Elevation regulation |
Minimum Requirement |
| Finished floor requirement |
One foot above the road |
| Requirement needed |
Slab Inspection |
| Document needed is |
Surveyor letter (FFE) |
| Document receieved |
Yes |
| Fema map number |
12023C0289D |
| This is the construction of a |
Single Family Dwelling |
| Stories |
1 |
| Heated Area (Sqft) |
1496 |
| Total Area (Sqft) |
2000 |
| Building Height |
19 |
| Building Code Edition |
2023 Florida Building Code 8th Edition and 2020 National Electrical Code |
| Septic# (00-0000) or (X00-000) |
25-0857 |
| Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) |
two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified. |
| Service Amps |
200 |
Review Notes
| 12/12/2025 |
Application pending. |
| 12/15/2025 |
Septic Approval Paperwork was not accepted. |
| 12/15/2025 |
Architectural Plans was not accepted. |
| 12/18/2025 |
Application is within the City of Lake City service area |
| 12/30/2025 |
Application Status Update Notification |
| 12/31/2025 |
Application Status Update Notification |
| 1/12/2026 |
Application Status Update Notification |
| 1/12/2026 |
Submitted by building department on applicant's behalf |
| 1/12/2026 |
City of Lake City Utilities Notified. |
| 1/16/2026 |
Application Status Update Notification |
| 1/16/2026 |
Permit Issued |
| 4/30/2026 |
Other was not accepted. |
| 5/1/2026 |
Permit Reissued |
| 6/3/2026 |
Permit Reissued |
Contractors
| Name / Business |
License |
Title |
Role |
Benjamin T Keeler Keeler Roofing, Llc
|
CCC1330509 |
Cert. Roofing |
Subcontractor |
Clinton G Wilson Wilson Heat & Air Inc
|
CAC057886 |
Class B A/c |
Subcontractor |
Cody Barrs Barrs Plumbing Inc
|
CFC1427145 |
Plumbing Contractor |
Subcontractor |
Joseph C Peurrung Benchmark Builders Llc
|
CBC1259347 |
Cert. Building |
Contractor |
Inspections
| Inspection |
Notes |
Performed By |
Date |
| Passed: Building - Footer |
|
Matt Forsyth |
3/12/2026 |
| Passed: Plumbing/Gas - 1st Underground Rough–In |
Waste Pipe Holding Water |
Matt Forsyth |
4/16/2026 |
| Passed: Building - Monolithic Slab |
|
Matt Forsyth |
5/1/2026 |
| Passed: Engineering - Setbacks |
|
Matt Forsyth |
5/1/2026 |
| Passed: Electrical - Footer Steel & Grounding |
|
Matt Forsyth |
5/1/2026 |
| Passed: Building - Wall Sheathing |
|
Matt Forsyth |
6/3/2026 |
| Passed: Building - Roof Decking |
|
Matt Forsyth |
6/3/2026 |
| Passed: Building - Ext Strapping/Wall Sheathing |
|
Matt Forsyth |
6/3/2026 |
| Passed: Building - Framing |
Envelope Framed In Except Windows And Doors |
Matt Forsyth |
6/3/2026 |