Allows temporary power for construction use. Ref: NEC Art. 230
No Notice of Commencement on file.
-
Verifies conduit, wiring, and grounding prior to backfill. Ref: NEC Art. 300.5
No Notice of Commencement on file.
-
Inspects drainage and water piping before backfill. Ref: FBC-P 312
No Notice of Commencement on file.
-
Inspects reinforcement, vapor barrier, termite treatment, and plumbing prior to pour. Ref: FBC 110.3(1)
No Notice of Commencement on file.
-
Confirms vertical and horizontal reinforcing per engineered plans. Ref: FBC 2122.2
No Notice of Commencement on file.
-
Ensures lintel/tie beam reinforcing steel and anchorage are correct before pour. Ref: FBC 110.3
No Notice of Commencement on file.
-
Checks roof sheathing attachment and fastener pattern per FBC wind zones. Ref: FBC 110.3(3)
No Notice of Commencement on file.
-
Reviews piping, venting, and fixtures before wall close. Ref: FBC-P 312
No Notice of Commencement on file.
-
Checks wiring, panel placement, and boxes before cover-up. Ref: NEC Art. 110.3
No Notice of Commencement on file.
-
Inspects conduit, junctions, and wiring above ceilings before close-up. Ref: NEC Art. 300.11
No Notice of Commencement on file.
-
Verifies underground piping installation. Ref: NFPA
No Notice of Commencement on file.
-
Hydrostatic test of underground fire main. Ref: NFPA 25
No Notice of Commencement on file.
-
Flushes underground water main. Ref: NFPA 25
No Notice of Commencement on file.
-
Pressure test of sprinkler piping aboveground. Ref: NFPA 13 §25.2
No Notice of Commencement on file.
-
Visual review of aboveground sprinkler piping layout. Ref: NFPA 13 §8.6
No Notice of Commencement on file.
-
Verifies wall sheathing, nailing, and exterior strapping per wind-load requirements. Ref: FBC 110.3, 1609
No Notice of Commencement on file.
-
Full review of fire systems before occupancy. Ref: FBC 907
No Notice of Commencement on file.
-
Confirms fire-related wall assemblies meet UL/FBC details and penetrations are properly sealed. Ref: FBC 703
No Notice of Commencement on file.
-
Confirms rated wall assemblies meet fire-resistance standards. Ref: FBC 703
No Notice of Commencement on file.
-
Inspects footing size, depth, and reinforcing steel before concrete placement. Ref: FBC 110.3(1)
No Notice of Commencement on file.
-
Reviews structural framing, load paths, fire blocking, and MEP rough-ins prior to insulation. Ref: FBC 110.3(3)
No Notice of Commencement on file.
-
Ensures dampers and duct penetrations are properly installed. Ref: FBC-M 607
No Notice of Commencement on file.
-
Inspects fire safety, anchoring, and venting of fuel tanks. Ref: NFPA 30
No Notice of Commencement on file.
-
Tests hydrant water flow and pressure. Ref: NFPA 14
No Notice of Commencement on file.
-
Verifies insulation type, R-value, and installation before drywall. Ref: FBC Energy C101.5
No Notice of Commencement on file.
-
Confirms grease/oil interceptor installation and connections. Ref: FBC-P 1003
No Notice of Commencement on file.
-
Inspects grease duct, clearances, and fire suppression tie-in. Ref: FBC-M 506
No Notice of Commencement on file.
-
Confirms hood suppression system works. Ref: NFPA 96
No Notice of Commencement on file.
-
Checks stucco lath, weep screeds, and moisture barriers before application. Ref: FBC 110.3
No Notice of Commencement on file.
-
Confirms duct/shaft tightness by testing for air-leakage. Ref: FBC-M 603.9
No Notice of Commencement on file.
-
Inspects smoke/shaft tightness by light test. Ref: FBC 907.5
No Notice of Commencement on file.
-
Verifies fire alarm functionality. Ref: NFPA 72
No Notice of Commencement on file.
-
Runs and verifies fire pump performance. Ref: NFPA 20
No Notice of Commencement on file.
-
Ensures driveway construction complies with Florida Department of Transportation standards when accessing a state-maintained road. Ref: FDOT Standard Index, Columbia County LDR 4.2.3
No Notice of Commencement on file.
-
Flow test for sprinkler/standpipe system. Ref: NFPA 13/14
No Notice of Commencement on file.
-
Ensures HVAC system airflow matches design. Ref: FBC Energy C403.2
No Notice of Commencement on file.
-
Verifies refrigerant and condensate piping pressure integrity. Ref: FBC-M 1108
No Notice of Commencement on file.
-
Checks roof drain and rain leader piping installation. Ref: FBC-P 1101
No Notice of Commencement on file.
-
Verifies fastening and components for fire-rated walls, ceilings, or roofs. Ref: FBC 703
No Notice of Commencement on file.
-
Inspects commercial refrigeration piping and systems. Ref: FBC-M 1108
No Notice of Commencement on file.
-
Checks ductwork, equipment location, and condensate before covering. Ref: FBC-M 603
No Notice of Commencement on file.
-
Reviews sanitary sewer piping installation. Ref: FBC-P 312
No Notice of Commencement on file.
-
Ensures proper base, vapor barrier, reinforcing, and termite treatment before pour. Ref: FBC 110.3(1)
No Notice of Commencement on file.
-
Reviews hurricane straps, anchors, and connections, for uplift resistance. Ref: FBC 1609
No Notice of Commencement on file.
-
Verifies water-tightness and slope before tile. Ref: FBC-P 312.9
No Notice of Commencement on file.
-
Checks filled masonry cells or columns for reinforcing and grout. Ref: FBC 2122.2
No Notice of Commencement on file.
-
Confirms nail/screw spacing and panel installation per plans. Ref: FBC 110.3(3)
No Notice of Commencement on file.
-
Checks water service piping for pressure and sizing. Ref: FBC-P 312.5
No Notice of Commencement on file.
-
Releases power once service equipment is complete and safe. Ref: NEC Art. 230
No Notice of Commencement on file.
-
Ensures structure is complete, safe, and code-compliant before Certificate of Occupancy. Ref: FBC 110.5
Assessment is owed.
No Notice of Commencement on file.
-
Ensures all zoning-related site requirements (buffers, landscaping, setbacks, parking) are satisfied before CO.
Columbia County LDR
Assessment is owed.
No Notice of Commencement on file.
Enter a permit number above to see the inspections available for it.