Building & Zoning

Inspection Request

Schedule a new inspection for your permit, or cancel one you have already scheduled.

  • Monday–Friday only
  • Requests after 5 PM can’t be for the next day
  • One active request per inspection
  1. Choose inspections
  2. Review & confirm
  3. Done

Request to Schedule Inspections

Enter your permit number, then tell us what you’d like to do.

Press Enter or tab out of the field to load this permit’s inspections.

New Commercial Construction 4917 E US HIGHWAY 90 LAKE CITY, FL 32055

Date & contact

Tell us when you need the inspector and how to reach you.

Select inspections

Check each inspection you need. An inspection that is already scheduled can’t be requested again until it is cancelled.

* Some inspections may not be available until Surveyor letter (FFE) is provided.
  • Allows temporary power for construction use. Ref: NEC Art. 230
  • Verifies conduit, wiring, and grounding prior to backfill. Ref: NEC Art. 300.5 Inspection was completed on 2026.05.14.
  • Inspects drainage and water piping before backfill. Ref: FBC-P 312 Inspection was completed on 2026.05.08.
  • Inspects footing size, depth, and reinforcing steel before concrete placement. Ref: FBC 110.3(1)
  • Inspects reinforcement, vapor barrier, termite treatment, and plumbing prior to pour. Ref: FBC 110.3(1) Inspection was completed on 2026.11.10.
  • Checks roof sheathing attachment and fastener pattern per FBC wind zones. Ref: FBC 110.3(3)
  • Reviews structural framing, load paths, fire blocking, and MEP rough-ins prior to insulation. Ref: FBC 110.3(3)
  • Confirms rated wall assemblies meet fire-resistance standards. Ref: FBC 703
  • Confirms fire-related wall assemblies meet UL/FBC details and penetrations are properly sealed. Ref: FBC 703
  • Ensures dampers and duct penetrations are properly installed. Ref: FBC-M 607
  • Verifies fastening and components for fire-rated walls, ceilings, or roofs. Ref: FBC 703
  • Checks ductwork, equipment location, and condensate before covering. Ref: FBC-M 603
  • Checks wiring, panel placement, and boxes before cover-up. Ref: NEC Art. 110.3
  • Reviews piping, venting, and fixtures before wall close. Ref: FBC-P 312
  • Verifies water-tightness and slope before tile. Ref: FBC-P 312.9
  • Full review of fire systems before occupancy. Ref: FBC 907
  • Verifies insulation type, R-value, and installation before drywall. Ref: FBC Energy C101.5
  • Verifies fire alarm functionality. Ref: NFPA 72
  • Flow test for sprinkler/standpipe system. Ref: NFPA 13/14
  • Flushes underground water main. Ref: NFPA 25
  • Hydrostatic test of underground fire main. Ref: NFPA 25
  • Verifies underground piping installation. Ref: NFPA
  • Conducted when required by the City to verify proper connection and availability of utility services. Ref: City of Lake City
  • Releases power once service equipment is complete and safe. Ref: NEC Art. 230 Lake City Utilities Tap Inspection must be passed prior to scheduling.
  • Ensures structure is complete, safe, and code-compliant before Certificate of Occupancy. Ref: FBC 110.5
  • Ensures all zoning-related site requirements (buffers, landscaping, setbacks, parking) are satisfied before CO. Columbia County LDR
Enter a permit number above to see the inspections available for it.