  • Inspects footing size, depth, and reinforcing steel before concrete placement. Ref: FBC 110.3(1)
  • Verifies conduit, wiring, and grounding prior to backfill. Ref: NEC Art. 300.5
  • Inspects drainage and water piping before backfill. Ref: FBC-P 312 Inspection was completed on 2024.09.11.
  • Ensures proper base, vapor barrier, reinforcing, and termite treatment before pour. Ref: FBC 110.3(1) Inspection was completed on 2024.09.13.
  • Inspects reinforcement, vapor barrier, termite treatment, and plumbing prior to pour. Ref: FBC 110.3(1)
  • Reviews structural framing, load paths, fire blocking, and MEP rough-ins prior to insulation. Ref: FBC 110.3(3)
  • Verifies wall sheathing, nailing, and exterior strapping per wind-load requirements. Ref: FBC 110.3, 1609
  • Confirms nail/screw spacing and panel installation per plans. Ref: FBC 110.3(3)
  • Verifies insulation type, R-value, and installation before drywall. Ref: FBC Energy C101.5
  • Ensures lintel/tie beam reinforcing steel and anchorage are correct before pour. Ref: FBC 110.3
  • Confirms vertical and horizontal reinforcing per engineered plans. Ref: FBC 2122.2
  • Checks roof sheathing attachment and fastener pattern per FBC wind zones. Ref: FBC 110.3(3)
  • Checks filled masonry cells or columns for reinforcing and grout. Ref: FBC 2122.2
  • Checks wiring, panel placement, and boxes before cover-up. Ref: NEC Art. 110.3
  • Allows temporary power for construction use. Ref: NEC Art. 230
  • Reviews piping, venting, and fixtures before wall close. Ref: FBC-P 312
  • Ensures structure is complete, safe, and code-compliant before Certificate of Occupancy. Ref: FBC 110.5
  • Releases power once service equipment is complete and safe. Ref: NEC Art. 230 Inspection was completed on 2026.11.02.