Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Roof Replacement or Repair Permit

Address 197 SW TANNER GLN
FORT WHITE, FL 32038
Parcel #: 03755-027
Acres: 4.00
Owner: Holt Randy Lee,
Subdivision: Columbia East-west
Zoning: A-3
Flood Zone: X
District: 4
Application #: 72191
Permit #: 000053661
Related Permit:
Submitted: Monday, July 21, 2025
Issued: Monday, July 28, 2025
Expires: Friday, August 8, 2025
Completed: Friday, August 8, 2025
Status: Completed
Septic Release? na
Notes:

Job Details
Finished floor requirement
Fema map number 12023C0395C
Type Roofing Job Replacement - Tear off Existing and Replace
Type of structure Mobile Home
Commercial or Residential Residential
Roof Area (for this job) Sq Ft 1433
No. of Stories 1
Roof Pitch 2:12 to 4:12
Is the existing roof being removed? Yes
Type of New Roofing Product Asphalt Shingles
Florida Product Approval Number FL10124.1
Other Roofing Product Type Not Listed Underlayment GAF Weatherwatch FL 10626.1
Product Manufacturer GAF
Product Description Timberline HDZ
Building Code Edition 2023 Florida Building Code 8th Edition and 2020 National Electrical Code
Sealed roof decking options: (Must select an option.) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Ventilation: Off-ridge Vent
Flashing: Use Existing
Drip Edge: Replace All
Valley Treatment: New Mineral Surface
Any cable and/or race-way wiring located on or within the roof assembly? No
Review Notes
7/21/2025 Application pending.
7/24/2025 Application submitted by applicant.
7/25/2025 Final Review - Corrections Needed NEEDED: *LEA UPDATED WORKERS COMP-- EMAIL TO INSURANCECERT@COLUMBIACOUNTYFLA.COM
7/28/2025 Final Review - Payment Needed
7/28/2025 Permit Issued Permit #000053661 created and approved.
7/28/2025 Final Review - Complete
Contractors
Name/ Business License Title Role
Titus Lea
Certified Roofing Solutions Llc
CCC1326502 Cert. Roofing Contractor
Inspections
Inspection Notes Performed By Date
Passed: Re-Roof - In Progress Troy Crews 8/6/2025
Passed: Re-Roof - Roof Affidavit Review Troy Crews 8/7/2025
Passed: Re-Roof - Roof Pictures Review Troy Crews 8/8/2025
Passed: Re-Roof - Final Troy Crews 8/8/2025