Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

Mobile Home Permit
Address 910 SW SHERLOCK TER
LAKE CITY, FL 32024
Parcel #: 03620-001
Acres: 1.00
Owner: Krzoska, Christopher & Wendy
Subdivision:
Zoning: A-3
Flood Zone: X
District: 5
Application #: 48415
Permit #: 000041467
Related Permit:
Submitted:
Issued: Friday, March 5, 2021
Expires: Monday, April 12, 2021
Completed: Monday, April 12, 2021
Status: Completed
Septic Release? Yes
Notes:
LOT OF RECORD PRIOR TO JUNE 1991 PER DEED.
Job Details
Mobile Home is a: Double Wide
Year Built 1993
Width (Ft.In) 28
Length (Ft.In) 56
Wind Zone? 2
Serial # flhmlcp477-9406ab
Installation Decal # 14506
Residential or Commercial Use? Residential
Driveway access to home: Existing Drive
Septic # (00-0000) or (X00-000) 21-0146
Dev Permit # F023-
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0390C
Review Notes
2/10/2021 Point Review - Received-Hard Copy Application
2/23/2021 Plan Review - Reviewed NEEDED: OUT OF COUNTY FORM MISSING A LOT OF INFORMATION - LH WILL CALL INSTALLER.. PRE-MH INSPECTION NEEDED EH JW SENT EMAIL - 2.11.21
2/23/2021 Zoning Review - Reviewed NEEDED: OUT OF COUNTY FORM MISSING A LOT OF INFORMATION - LH WILL CALL INSTALLER.. PRE-MH INSPECTION NEEDED EH JW SENT EMAIL - 2.11.21
2/23/2021 Final Review - Documents Required NEEDED: (LH SPOKE TO INSTALLER 2/23/21) PRE-MH INSPECTION NEEDED EH JW SENT EMAIL - 2.11.21
3/5/2021 Final Review - Payment Needed NEEDED: (LH SPOKE TO INSTALLER 2/23/21)
3/5/2021 Permit Issued Permit #000041467 created and approved.
Contractors
Name/ Business License Title Role
Manuel M Brannan
Mikes Mobile Setup Llc
IH1025396 Mh Installer (ih) Contractor
Inspections
Inspection Notes Performed By Date
Passed: Mobile Home - In County Pre-Mobile Home before set-up Matt Forsyth 3/1/2021
Septic Release Inspection Health Dept 3/9/2021
Failed: Mobile Home - Mobile Home Set-Up Final Need Proof Of Heat In Home,need Landing At Top Of Stairs ,gable End Both Sides Not Finished (need Trim Down Middle ) Matt Forsyth 4/5/2021
Passed: Engineering - Setbacks Matt Forsyth 4/5/2021
Passed: Mobile Home - Mobile Home Set-Up Final Matt Forsyth 4/12/2021
Release to power company Matt Forsyth 4/12/2021
Passed: Engineering - Setbacks Matt Forsyth 4/12/2021