Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 468 SW MAGNOLIA LN
FORT WHITE, FL 32038
Parcel #: 10058-308
Acres: 2.15
Owner: Herring Owen Dennis Jr & Patricia H Herring
Subdivision: Santa Fe River Plantations
Zoning: A-3
Flood Zone: X
District: 2
Application #: 48120
Permit #: 000041357
Related Permit: Culvert Waiver: 000041356
Submitted: Thursday, January 7, 2021
Issued: Friday, February 19, 2021
Expires: Monday, November 8, 2021
Completed: Monday, November 8, 2021
Status: Completed
Septic Release? Yes
Notes:

Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0532C
In floodway N
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1693
Total Area (Sqft) 2550
Stories 1
Building Height 16
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Septic# (00-0000) or (X00-000) 21-0119
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
1/7/2021 Application pending.
1/7/2021 Point Review - On Hold-Incomplete
1/7/2021 Application Converted
1/19/2021 Point Review - Printed-Online Application
1/19/2021 Zoning Review - Reviewed
1/22/2021 Plan Review - Documents Required
1/27/2021 Point Review - Printed-Online Application
1/27/2021 Point Review - Printed-Online Application
2/16/2021 Plan Review - Reviewed
2/18/2021 Zoning Review - Reviewed
2/18/2021 Final Review - Payment Needed
2/19/2021 Permit Issued
8/23/2021 Final Review - Payment Needed
8/23/2021 Final Review - Complete
Contractors
Name/ Business License Title Role
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Chad White
Ck Contracting Inc
County License & State License & Liability Insurance & Workers Comp Expired.
CGC1516925 General Contractor Subcontractor
Paul K Coleman
Coleman's Plumbing Inc.
CFC1425624 Certified Plumbing Subcontractor
Joel G Buzbee
G Buzbee, Inc
Liability Insurance & Workers Comp Expired.
CGC061980 Cert General Contractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Anthony Aslan 2/25/2021
Release to power company Anthony Aslan 2/25/2021
Release to power company Melissa Garber 3/8/2021
Passed: Building - Footer Anthony Aslan 3/12/2021
Passed: Engineering - Setbacks Anthony Aslan 3/12/2021
Passed: Building - Masonry Wall Reinforcing Anthony Aslan 3/30/2021
Passed: Plumbing/Gas - 1st Underground Rough–In 60'psi At Inspection Anthony Aslan 4/7/2021
Passed: Building - Slab Need Concrete Tickets Showing Fiber Mesh In Permit Box Anthony Aslan 5/3/2021
Passed: Building - Roof Decking Anthony Aslan 5/19/2021
Passed: Building - Wall Sheathing Anthony Aslan 5/19/2021
Cancelled: Building - Roof Decking Anthony Aslan 5/27/2021
Cancelled: Building - Wall Sheathing Anthony Aslan 5/27/2021
Failed: Building - Framing Engineering Missing On T08 Truss, Also Dryer Box Can Not Oval Pipe And Laundry Wall Needs To Be Furred Out. Anthony Aslan 6/3/2021
Failed: Building - Framing T08 Missing Engineering, There Are Two Truss Anthony Aslan 6/11/2021
Passed: Building - Framing Added Engineering To T08 Anthony Aslan 6/16/2021
Passed: Electrical - 2nd Rough-In Anthony Aslan 6/30/2021
Passed: Mechanical - Rough In Anthony Aslan 6/30/2021
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 6/30/2021
Passed: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 6/30/2021
Passed: Plumbing/Gas - Tub Set/Shower Pan Master Tub Anthony Aslan 7/12/2021
Passed: Building - Insulation Walls Only Anthony Aslan 7/12/2021
Septic Release Inspection Health Dept 8/19/2021
Cancelled: Electrical - 2nd Rough-In Anthony Aslan 8/23/2021
Passed: Electrical - Permanent Power Anthony Aslan 8/23/2021
Release to power company Anthony Aslan 8/23/2021
Release to power company Melissa Garber 8/27/2021
Passed: Building - Final Anthony Aslan 11/8/2021
Documents
File Name Date File Size
Application Packet 2019-12-20 12.40.59 Pm.pdf 2023.12.25 141.43kB
Application Packet 2019-12-20 1.14.58 Pm.pdf 2023.12.25 583.72kB