Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 468 SW MAGNOLIA LN
FORT WHITE, FL 32038
Parcel #: 10058-308
Acres: 2.15
Owner: Herring Owen Dennis Jr & Patricia H Herring
Subdivision: Santa Fe River Plantations
Zoning: A-3
Flood Zone: X
District: 2
Application #: 48120
Permit #: 000041357
Related Permit: Culvert Waiver: 000041356
Submitted: Thursday, January 7, 2021
Issued: Friday, February 19, 2021
Expires: Monday, November 8, 2021
Completed: Monday, November 8, 2021
Status: Completed
Septic Release? Yes
Notes:

Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0532C
In floodway N
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1693
Total Area (Sqft) 2550
Stories 1
Building Height 16
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Septic# (00-0000) or (X00-000) 21-0119
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Sealed roof decking options. (Must select one option per FBC 2020 7th Edition) two layers of felt underlayment comply ASTM 0226 Type II or ASTM D4869 Type Ill or IV, or two layers of a synthetic underlayment meeting the performance requirements specified, lapped and fastened as specified.
Review Notes
1/7/2021 Application pending.
1/7/2021 Point Review - On Hold-Incomplete
1/7/2021 Application Converted Application was converted from Culvert Waiver to New Residential Construction
1/19/2021 Point Review - Printed-Online Application JW SPOKE WITH G. BUZBEE - 1.7.21 NEEDED: RESIDENTIAL CHECKLIST & ENG. TRUSS REPORT OWNER SIGNATURE PAGE W/CONTRACTOR SIGNATURE BEING NOTARIZED BUZBEE CERT. OF LIABILITY ROOFING(?)
1/19/2021 Zoning Review - Reviewed JW SPOKE WITH G. BUZBEE - 1.7.21 NEEDED: RESIDENTIAL CHECKLIST & ENG. TRUSS REPORT OWNER SIGNATURE PAGE W/CONTRACTOR SIGNATURE BEING NOTARIZED BUZBEE CERT. OF LIABILITY & DONALD DAVIS CERT OF LIAB ROOFING(?)
1/22/2021 Plan Review - Documents Required NEEDED: DONALD DAVIS - CERT. OF LIABILITY EH - 386.758.1058 - SAL MOBLEY NEED HARD COPIES OF WINDLOAD ANALYSIS NO COPIES PERMITTED BY ENGINEER
1/27/2021 Point Review - Printed-Online Application NEEDED: DONALD DAVIS - CERT. OF LIABILITY EH - 386.758.1058 - SAL MOBLEY NEED HARD COPIES OF WINDLOAD ANALYSIS NO COPIES PERMITTED BY ENGINEER
1/27/2021 Point Review - Printed-Online Application NEEDED: DONALD DAVIS - CERT. OF LIABILITY EH - 386.758.1058 - SAL MOBLEY NEED HARD COPIES OF WINDLOAD ANALYSIS NO COPIES PERMITTED BY ENGINEER
2/16/2021 Plan Review - Reviewed NEEDED: DONALD DAVIS - CERT. OF LIABILITY-REC'D EH - 386.758.1058 - SAL MOBLEY NEED HARD COPIES OF WINDLOAD ANALYSIS NO COPIES PERMITTED BY ENGINEER HARD COPIES RECEIVED 2-16-21
2/18/2021 Zoning Review - Reviewed NEEDED: DONALD DAVIS - CERT. OF LIABILITY-REC'D EH - 386.758.1058 - SAL MOBLEY- REC'D NEED HARD COPIES OF WINDLOAD ANALYSIS NO COPIES PERMITTED BY ENGINEER HARD COPIES RECEIVED 2-16-21
2/18/2021 Final Review - Payment Needed NEEDED: DONALD DAVIS - CERT. OF LIABILITY-REC'D EH - 386.758.1058 - SAL MOBLEY- REC'D NEED HARD COPIES OF WINDLOAD ANALYSIS NO COPIES PERMITTED BY ENGINEER HARD COPIES RECEIVED 2-16-21
2/19/2021 Permit Issued Permit #000041357 created and approved.
8/23/2021 Final Review - Payment Needed NEEDED: DONALD DAVIS - CERT. OF LIABILITY-REC'D EH - 386.758.1058 - SAL MOBLEY- REC'D NEED HARD COPIES OF WINDLOAD ANALYSIS NO COPIES PERMITTED BY ENGINEER HARD COPIES RECEIVED 2-16-21
8/23/2021 Final Review - Complete
Contractors
Name/ Business License Title Role
Donald Davis
High Springs Electric Inc
EC0002306 Electrical Contractor Subcontractor
Chad White
Ck Contracting Inc
County License & State License & Liability Insurance & Workers Comp Expired.
CGC1516925 General Contractor Subcontractor
Paul K Coleman
Coleman's Plumbing Inc.
CFC1425624 Certified Plumbing Subcontractor
Joel G Buzbee
G Buzbee, Inc
Workers Comp Expired.
CGC061980 Cert General Contractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Anthony Aslan 2/25/2021
Release to power company Anthony Aslan 2/25/2021
Release to power company Melissa Garber 3/8/2021
Passed: Building - Footer Anthony Aslan 3/12/2021
Passed: Engineering - Setbacks Anthony Aslan 3/12/2021
Passed: Building - Masonry Wall Reinforcing Anthony Aslan 3/30/2021
Passed: Plumbing/Gas - 1st Underground Rough–In 60'psi At Inspection Anthony Aslan 4/7/2021
Passed: Building - Slab Need Concrete Tickets Showing Fiber Mesh In Permit Box Anthony Aslan 5/3/2021
Passed: Building - Roof Decking Anthony Aslan 5/19/2021
Passed: Building - Wall Sheathing Anthony Aslan 5/19/2021
Cancelled: Building - Roof Decking Anthony Aslan 5/27/2021
Cancelled: Building - Wall Sheathing Anthony Aslan 5/27/2021
Failed: Building - Framing Engineering Missing On T08 Truss, Also Dryer Box Can Not Oval Pipe And Laundry Wall Needs To Be Furred Out. Anthony Aslan 6/3/2021
Failed: Building - Framing T08 Missing Engineering, There Are Two Truss Anthony Aslan 6/11/2021
Passed: Building - Framing Added Engineering To T08 Anthony Aslan 6/16/2021
Passed: Electrical - 2nd Rough-In Anthony Aslan 6/30/2021
Passed: Mechanical - Rough In Anthony Aslan 6/30/2021
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 6/30/2021
Passed: Plumbing/Gas - Tub Set/Shower Pan Anthony Aslan 6/30/2021
Passed: Plumbing/Gas - Tub Set/Shower Pan Master Tub Anthony Aslan 7/12/2021
Passed: Building - Insulation Walls Only Anthony Aslan 7/12/2021
Septic Release Inspection Health Dept 8/19/2021
Cancelled: Electrical - 2nd Rough-In Anthony Aslan 8/23/2021
Passed: Electrical - Permanent Power Anthony Aslan 8/23/2021
Release to power company Anthony Aslan 8/23/2021
Release to power company Melissa Garber 8/27/2021
Passed: Building - Final Anthony Aslan 11/8/2021
Documents
File Name Date File Size
Termite Treatment_initial 20210504 074748.pdf 2023.12.24 168.59kB
Original Permit 20210219.pdf 2023.12.24 42.72kB
Septic Approval Paperwork 20210210 115107.pdf 2023.12.24 1.13MB
Truss Engineering 20210121 100310.pdf 2023.12.24 414.76kB
Manual J Forms 20210118 181117.pdf 2023.12.24 358.04kB
Product Approval Code Specifications Form 20210118 184651.pdf 2023.12.24 147.31kB
Residential Or Commercial Checklist 20210121 100309.pdf 2023.12.24 1.80MB
Power Release-release To Power Company 20210308.pdf 2023.12.24 39.12kB
Lidar 48120 2021-01-19 10.46.22.669.pdf 2023.12.24 112.60kB
Certificate Of Occupancy 20211108.pdf 2023.12.24 62.14kB
Site Plan 20210118 181117.pdf 2023.12.24 24.74kB
Fields From Application Type Culvert Waiver.xlsx 2023.12.24 11.82kB
Power Release-electrical-permanent Power 20210823.pdf 2023.12.24 39.24kB
Architectural Plans 20210118 181116.pdf 2023.12.24 248.40kB
Approved Trusses 48120 2021-01-22 13.37.14.789.pdf 2023.12.24 453.28kB
Structural Engineering And Wind Load Calculations 20210118 181118.pdf 2023.12.24 3.12MB
Power Release-electrical-temporary Service 20210225.pdf 2023.12.24 39.11kB
Power Release-release To Power Company 20210827.pdf 2023.12.24 39.24kB
911 Sheet.pdf 2023.12.24 81.81kB
Energy Code Forms 20210118 181116.pdf 2023.12.24 282.55kB
Recorded Deed 20210118 181117.pdf 2023.12.24 71.65kB
Subcontractor Form 20210118 183516.pdf 2023.12.24 277.18kB
Owner And Contractor Signature Page 20210121 100309.pdf 2023.12.24 427.21kB
Property Appraiser Parcel Details Printed Page 20210107 163048.pdf 2023.12.24 450.54kB
Blower Door Test Results 20211109 082047.pdf 2023.12.24 373.60kB
41357 Final Termite Spray 2021-11-15 13.25.19.02.jpg 2023.12.24 544.42kB
Recorded Notice Of Commencement 20210122 122805.pdf 2023.12.24 415.79kB