Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 352 SW BELLFLOWER DR
LAKE CITY, FL 32024
Parcel #: 02731-052
Acres: 0.30
Owner: The Preserves At Laurel Lakes Inc
Subdivision: Preserve At Laurel Lake
Zoning: PRD
Flood Zone: X
District: 3
Application #: 47945
Permit #: 000041331
Related Permit: Culvert Waiver: 000041332
Submitted: Wednesday, November 24, 2021
Issued: Tuesday, February 16, 2021
Expires: Thursday, December 9, 2021
Completed: Thursday, December 9, 2021
Status: Completed
Septic Release? Yes
Notes:
CHECK FRONT 26' SETBACK IN FIELD ELEVATION CONFIRMATION LETTER REC'D @ 112.6'
Job Details
Finished floor requirement
Fema map number 12023C0495C
Type of connection for access road Verify Existing Drive
Type of construction of property Other
If the type of construction is not listed, please describe below Accessory Pole Barn
Normal vehicle usage: Automobiles
Estimated Number of Vehicle trips per day 1
Is the access for commercial or residential use? Residential
Review Notes
12/9/2020 Point Review - Received-Hard Copy Application
12/9/2020 Point Review - Reviewed
12/10/2020 Zoning Review - Reviewed
12/15/2020 Plan Review - Reviewed
12/17/2020 Zoning Review - Reviewed
12/18/2020 Final Review - Documents Required
2/11/2021 Final Review - Payment Needed
2/16/2021 Permit Issued
10/12/2021 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Aaron Simque
Aaron Simque Homes Inc
County License & State License & Liability Insurance & Workers Comp Expired.
RR282811879 Residential Contractor Contractor
Stephen M Brisbois
Epic Ac Service
CAC1819412 Cert. A/c Class “b” Subcontractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Ralph W Laverdure
Rwl Roofing,llc.
CCC1328590 Roofing Contractor Subcontractor
Billy B Rathel Jr
Five Star Plumbing Big Bend, Inc.
Liability Insurance & Workers Comp Expired.
CFC1427547 Cert. Plumbing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Troy Crews 3/12/2021
Passed: Engineering - Setbacks Troy Crews 3/12/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Waste Only Troy Crews 4/12/2021
Passed: Building - Slab Need Ticket For Termite Spray Troy Crews 4/27/2021
Passed: Building - Wall Sheathing Troy Crews 6/3/2021
Passed: Building - Roof Decking Troy Crews 6/3/2021
Failed: Building - Framing T12truss Calling For 1936 Uplift Mid Span Missing Matt Forsyth 6/23/2021
Passed: Electrical - 2nd Rough-In Matt Forsyth 6/23/2021
Failed: Mechanical - Rough In No Work Done Matt Forsyth 6/23/2021
Passed: Building - Framing Matt Forsyth 7/21/2021
Cancelled: Electrical - 2nd Rough-In Matt Forsyth 7/21/2021
Failed: Mechanical - Rough In Duck Work Coming Through Ceiling For Plentem Needs 3" Clearance. All Hv Ac Boots In Ceiling Need Gasket Matt Forsyth 7/21/2021
Failed: Plumbing/Gas - 2nd Rough-In Work Not Complete Matt Forsyth 7/21/2021
Cancelled: Electrical - 2nd Rough-In Troy Crews 8/16/2021
Failed: Building - Insulation Spot Loose In Garage, Back Wall Water Line Added Needs Nail Plate And Also Displaced Insulation Troy Crews 8/17/2021
Failed: Mechanical - Rough In Return Registers Dont Have Seals, Also Oven Duct Must Have Smooth Interior, Dont Sheetrock Until Re Inspected Troy Crews 8/17/2021
Failed: Plumbing/Gas - 2nd Rough-In Nail Plate Needed On Water Line Added Rear Wall Troy Crews 8/17/2021
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 8/23/2021
Failed: Building - Insulation Fallen Out Several Spots Troy Crews 8/24/2021
Failed: Mechanical - Rough In Oven Duct Not Replaced Troy Crews 8/24/2021
Failed: Building - Insulation Spot Still Missing At Rear Wall At Hose Bib Troy Crews 8/26/2021
Failed: Mechanical - Rough In No Duct For Oven Hood Troy Crews 8/26/2021
Passed: Building - Insulation Troy Crews 8/27/2021
Passed: Mechanical - Rough In Oven Hood Eliminated Look For Ventless Hood At Final Troy Crews 8/27/2021
Passed: Electrical - Permanent Power Troy Crews 10/13/2021
Release to power company Troy Crews 10/13/2021
Certificate-Release Certificate Insulation Verified Troy Crews 12/9/2021
Passed: Building - Final Need Pictures Of Attic Insulation Troy Crews 12/9/2021
Documents
File Name Date File Size
Driveway_application_drawing.jpg 2025.10.17 86.82kB
Image.jpg 2025.10.17 3.75MB
Original Permit 20251016.pdf 2025.10.17 28.86kB
Inspections Checklist.pdf 2025.10.17 101.69kB
Application.pdf 2025.10.14 38.92kB