Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 840 SE WORKER BEE GLN
HIGH SPRINGS, FL 32643
Parcel #: 09876-002
Acres: 29.20
Owner: Rogers Timmy & Rhonda T
Subdivision:
Zoning: A-3
Flood Zone: X
District: 4
Application #: 47644
Permit #: 000041081
Related Permit:
Submitted: Thursday, November 12, 2020
Issued: Wednesday, December 30, 2020
Expires: Friday, October 29, 2021
Completed: Friday, October 29, 2021
Status: Completed
Septic Release? Yes
Notes:
LEGAL LOT OF RECORD LINEAL DESCENDANTS
Job Details
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0511C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 1496
Total Area (Sqft) 2494
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family dwelling
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 20-1006
Review Notes
10/26/2020 Application pending.
11/13/2020 Point Review - Printed-Online Application
11/13/2020 Point Review - On Hold-Incomplete
12/14/2020 Zoning Review - Reviewed
12/14/2020 Point Review - Reviewed
12/18/2020 Plan Review - Reviewed
12/30/2020 Zoning Review - Reviewed
12/30/2020 Permit Issued Permit #000041081 created and approved.
9/13/2021 Zoning Review - Reviewed
9/13/2021 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Jason Roberts
Southtrust Construction Llc
Liability Insurance Expired.
CBC1257119 Cert. Building Contractor
Ryan C Beville
Rbi Electrical Contracting Llc
Employees Workers Comp Expired.
EC13004236 Electrical Contractor Subcontractor
James Bertie
Bertie Heating Air Conditioning
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CAC058522 Class B A/c Subcontractor
George M Mc Dilda
Hogtown Plumbing Inc
Liability Insurance & Workers Comp Expired.
CFC1427052 Cert Plumbing Subcontractor
William P Duffield
Duffield Home Improvement
CCC1325785 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Anthony Aslan 12/31/2020
Release to power company Anthony Aslan 12/31/2020
Passed: Building - Footer Need Porta Potty Before Next Inspection. Anthony Aslan 2/2/2021
Passed: Engineering - Setbacks Anthony Aslan 2/2/2021
Failed: Plumbing/Gas - 1st Underground Rough–In Need To Get Air Out Of Drain Piping, Anthony Aslan 2/26/2021
Failed: Plumbing/Gas - 1st Underground Rough–In Water Test Incomplete. Still Have Pipe With No Water. Anthony Aslan 3/2/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Anthony Aslan 3/4/2021
Passed: Building - Slab Anthony Aslan 3/15/2021
Failed: Building - Framing Missing H2.5's. Truss Check Engineering On R04, R09. Gables Show Ltsa24 4'ft O.c., Also Show 2x4 Blocking Between Truss With H2.5 Horizontally Strapped. Straps Missing Nails, No Post Set. Red Marker Where Missing Nails On Exterior Sheathing. Anthony Aslan 4/26/2021
Passed: Building - Roof Decking Anthony Aslan 4/26/2021
Failed: Building - Wall Sheathing Missing Nails Red Marker Anthony Aslan 4/26/2021
Passed: Building - Wall Sheathing Anthony Aslan 4/27/2021
Cancelled: Building - Wall Sheathing Anthony Aslan 6/30/2021
Passed: Building - Strapping Anthony Aslan 6/30/2021
Failed: Building - Framing Missing Anchors At Bottom Plate Splices Anthony Aslan 6/30/2021
Passed: Electrical - 2nd Rough-In Anthony Aslan 6/30/2021
Passed: Plumbing/Gas - 2nd Rough-In Anthony Aslan 6/30/2021
Failed: Mechanical - Rough In Fresh Air Needs To Be Accessible And Have Automatic Or Gravity Damper Installed kitchen Exhaust Missing Screws In Seam Joints Anthony Aslan 7/1/2021
Failed: Mechanical - Rough In Fresh Air Not Corrected Anthony Aslan 7/2/2021
Passed: Building - Framing Anthony Aslan 7/2/2021
Passed: Building - Insulation Fresh Air Damper Still Not Corrected Anthony Aslan 7/16/2021
Passed: Electrical - Permanent Power Need Septic Final Troy Crews 9/15/2021
Release to power company Melissa Garber 9/27/2021
Septic Release Inspection Health Dept 9/27/2021
Cancelled: Building - Final Melissa Garber 10/22/2021
Passed: Building - Final Two Outlets In Kitchen Counter Corner Not Gfci Anthony Aslan 10/29/2021
Documents
File Name Date File Size
Energy Code Forms 20201117 160234.pdf 2025.06.22 40.33kB
Manual J Forms 20201117 160157.pdf 2025.06.22 122.83kB
Lidar 47644 2020-12-14 09.47.26.532.pdf 2025.06.22 165.42kB
Subcontractor Form 20201119 075143.pdf 2025.06.22 100.14kB
Blower Door Test Results 20211101 082547.pdf 2025.06.22 238.02kB
Product Approval Code Specifications Form 20201211 122040.pdf 2025.06.21 418.53kB
Residential Or Commercial Checklist 20201211 122040.pdf 2025.06.21 538.85kB
Owner And Contractor Signature Page 20201112 174656.pdf 2025.06.21 426.90kB
Site Plan 20201119 075142.pdf 2025.06.20 151.45kB
911 Address Form 20201119 075141.pdf 2025.06.20 226.98kB
Structural Engineering And Wind Load Calculations 20201117 182830.pdf 2025.06.20 4.42MB
Architectural Plans 20201117 121022.pdf 2025.06.20 4.42MB
Approved Structural 47644 2020-12-18 07.40.06.384.pdf 2025.06.20 4.45MB
Certificate Of Occupancy 20211029.pdf 2021.10.29 62.23kB
Power Release-release To Power Company 20210927.pdf 2021.09.27 38.88kB
Power Release-electrical-temporary Service 20201231.pdf 2020.12.31 38.73kB
Original Permit 20201230.pdf 2020.12.30 42.74kB
Approved Truss Plans 47644 2020-12-18 07.36.33.281.pdf 2020.12.18 3.65MB
Rogers Eh 2020-12-16 14.42.27.187.pdf 2020.12.16 411.40kB
Recorded Notice Of Commencement 20201214 153126.pdf 2020.12.14 63.39kB
Truss Engineering 20201117 182445.pdf 2020.11.17 833.90kB
Truss Engineering 20201117 121252.pdf 2020.11.17 3.77MB
Recorded Deed 20201112 174657.pdf 2020.11.12 71.73kB