Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Commercial Construction Permit
Address 970 SW PINEMOUNT RD
LAKE CITY, FL 32024
Parcel #: 02745-003
Acres: 80.35
Owner: Sorensen Gary
Subdivision:
Zoning: CG
Flood Zone: X
District: 3
Application #: 47396
Permit #: 000041079
Related Permit: Culvert: 000041078
Submitted: Monday, November 22, 2021
Issued: Wednesday, December 30, 2020
Expires: Monday, December 6, 2021
Completed: Monday, December 6, 2021
Status: Completed
Septic Release? Yes
Notes:

Job Details
This is the construction of a: assisted living facilty
Describe commercial use: GRANDE CYPRESS ASSISTED LIVING FACILITY
Heated Area (Sqft) 21317.56
Total Area (Sqft) 27717.46
Stories 2
Building Height 24
Driveway access to property: Culvert Permit
Is there a Fire Sprinkler System? Yes
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title assisted living facility
Design Occupant Load 135
Setbacks Front 20'
Setback Side 1 5'
Setback Side 2 5'
Setback Rear 15'
Septic# (00-0000) or (X00-000) XCITY
Dev Permit # F023-
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Elevation regulation Site & Development Plan
Finished floor requirement 119'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0290D
In floodway N
Review Notes
9/29/2020 Point Review - Received-Hard Copy Application
10/26/2020 Plan Review - Reviewed
10/29/2020 Zoning Review - Reviewed
10/29/2020 Final Review - Documents Required
12/14/2020 Zoning Review - Documents Required
12/23/2020 Zoning Review - Reviewed
12/29/2020 Plan Review - Reviewed
12/30/2020 Final Review - Payment Needed
12/30/2020 Permit Issued Permit #000041079 created and approved.
9/17/2021 Final Review - Payment Needed JW SENT EMAIL 09.30.20 NEED: CITY WATER AND SEWER AVAILABILITY LETTER - REC'D 12.21.20 NFPS TO SUBMIT A MINOR MODIFICATION TO SITE PLAN. 12/14/20 - ONCE APPROVED, WILL REPLACE SITE PLAN IN PERMIT FILE. MINOR MODIFICATION SUMITTED ON 12/17/20. APPROVED ON 12/23/20. APPROVED MODIFIED SITE PLAN HAS BEEN UPLOADED. BS REVISED SITE PLAN MODIFIED THE BUILDING. DO THE BUILDING PLANS MATCH THE REVISED SITE PLAN? BS
Contractors
Name/ Business License Title Role
Gerald M Smith Sr
S&s Construction Llc
County License & State License & Liability Insurance Expired.
CBC1254161 Building Contractor Contractor
Lyndon J Rainbolt
Rainbolt Tech Services,air Stream
County License & State License & Liability Insurance & Workers Comp Expired.
EC13001835 Electrical Contractor Subcontractor
Christopher Williams
Christopher A Williams Inc Dba-country Comfort Heating & Ac
County License & State License & Liability Insurance & Workers Comp Expired.
CAC057795 Class "b" A/c Subcontractor
Daniel Mossburg
Live Oak Plumbing, Inc.
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CFC1427438 Plumbing Contractor Subcontractor
Benjamin T Keeler
Keeler Roofing, Llc
CCC1330509 Cert. Roofing Subcontractor
Santos Santiago
Caribbean Fire & Associates, Inc.
County License & State License & Liability Insurance & Workers Comp Expired.
696987-0001-1996 Fire System Subcontractor
Eric A Neilinger
Caribbean Fire & Security, Inc.
County License & State License & Liability Insurance & Workers Comp Expired.
EF20000969 Alarm System Contracto 1 Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 12/30/2020
Cancelled: Building - Footer Troy Crews 2/23/2021
Cancelled: Engineering - Setbacks Troy Crews 2/23/2021
Passed: Building - Footer Install Footer Grounding Wire Per Plan Troy Crews 3/10/2021
Passed: Engineering - Setbacks Troy Crews 3/10/2021
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 3/31/2021
Passed: Building - Slab Reminder Need Floor Elevation Confirmation Prior To Nailing Inspection. Troy Crews 4/13/2021
Cancelled: Building - Strapping Troy Crews 5/14/2021
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 5/14/2021
Passed: Building - Wall Sheathing Troy Crews 5/14/2021
Passed: Building - Roof Decking Troy Crews 6/10/2021
Passed: Building - Framing Partial Troy Crews 6/14/2021
Passed: Building - Slab 2 Front Covered Porches Troy Crews 6/23/2021
Passed: Electrical - Temporary Service Troy Crews 7/16/2021
Release to power company Troy Crews 7/16/2021
Passed: Electrical - 2nd Rough-In Troy Crews 7/27/2021
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 7/27/2021
Passed: Building - Insulation Exterior Walls, Call Back In For Second Floor And Sunroom Ceiling Troy Crews 8/9/2021
Passed: Mechanical - Rough In Reminder Need Updated Ac And Floor Plans Troy Crews 8/11/2021
Failed: Electrical - Permanent Power Need Driveway Final, Also Need All Exterior Doors . Troy Crews 9/20/2021
Passed: Electrical - Temporary Service Driveway Must Be Done Prior To C.o. Troy Crews 10/8/2021
Release to power company Troy Crews 10/8/2021
Passed: Electrical - Permanent Power As Built Plans, Including Electric Service Change And New Driveway Final Prior To Co Troy Crews 10/14/2021
Release to power company Troy Crews 10/14/2021
Passed: Building - Final Waiting On Zoning Final And Culvert Final For Release Troy Crews 12/2/2021
Passed: Engineering - Zoning Final Brandon Stubbs 12/3/2021
Passed: Engineering - Final Driveway Jones, Richard 12/3/2021
Passed: Engineering - Zoning Final Brandon Stubbs 12/6/2021
Documents
File Name Date File Size
Truss Engineering 20210106 125547.pdf 2023.12.26 38.00MB
Se 0592 - Minor Mod Site Plan 12-17-20 2020-12-23 09.37.53.887.pdf 2023.12.26 4.86MB
Termite Spray 41079 2021-04-13 07.13.48.444.msg 2023.12.26 328.00kB
Energy Code Forms 20210106 125247.pdf 2023.12.26 1.44MB
Mza 0009 - Minor Mod Approval 2020-12-23 09.38.05.372.pdf 2023.12.26 191.19kB
Manual J Forms 20210106 125246.pdf 2023.12.26 1.48MB
Application Information Page 20210106 124749.pdf 2023.12.26 348.63kB
Power Release-electrical-permanent Power 20211014.pdf 2023.12.26 39.12kB
Subcontractor Form 20210106 124946.pdf 2023.12.26 979.63kB
Fire Department Letter 20210106 125047.pdf 2023.12.26 416.93kB
Original Permit 20201230.pdf 2023.12.26 44.60kB
Surveyor Finished Floor Elevation Confirmation Letter 41079 2021-05-13 09.05.05.147.pdf 2023.12.26 22.22kB
City Or County Utility Availability Letter 20210106 125047.pdf 2023.12.26 255.58kB
911 Address Form 20210106 124846.pdf 2023.12.26 275.02kB
Certificate Of Occupancy 20211206.pdf 2023.12.26 120.98kB
Corrected Total Floor Area App. 47396 2020-12-29 13.58.20.445.pdf 2023.12.26 458.60kB
Power Release-electrical-temporary Service 20211008.pdf 2023.12.26 39.00kB
Hydraulic Overview Report.pdf 2023.12.26 2.15MB
Power Release-electrical-temporary Service 20210716.pdf 2023.12.26 38.88kB
Residential Or Commercial Checklist 20210106 125147.pdf 2023.12.26 1.94MB
Property Appraiser Parcel Details Printed Page 20210106 125048.pdf 2023.12.26 395.14kB
Recorded Notice Of Commencement 20210106 124847.pdf 2023.12.26 766.75kB
Owner And Contractor Signature Page 20210106 124749.pdf 2023.12.26 446.45kB
Product Approval Code Specifications Form 20210106 125046.pdf 2023.12.26 352.77kB
Site Survey Modification.pdf 2023.12.26 7.59MB
Recorded Deed 20210106 124848.pdf 2023.12.26 1.53MB
Plans 2021-01-07 10.03.00.258.pdf 2023.12.26 35.77MB