Inspection |
Notes |
Performed By |
Date |
Passed: Plumbing/Gas - 1st Underground Rough–In |
|
Matt Forsyth |
12/23/2020 |
Passed: Building - Footer |
|
Matt Forsyth |
1/8/2021 |
Passed: Engineering - Setbacks |
|
Matt Forsyth |
1/8/2021 |
Failed: Building - Ext Strapping/Wall Sheathing |
Need Gable Endwall Strapping |
Matt Forsyth |
2/22/2021 |
Passed: Building - Ext Strapping/Wall Sheathing |
|
Matt Forsyth |
2/26/2021 |
Passed: Electrical - Temporary Service |
|
Anthony Aslan |
3/24/2021 |
Release to power company |
|
Anthony Aslan |
3/24/2021 |
Failed: Building - Framing |
Need Engineering Letter For Portal Frame In Garage Was Not Built To Design |
Matt Forsyth |
4/1/2021 |
Passed: Electrical - 2nd Rough-In |
|
Matt Forsyth |
4/1/2021 |
Passed: Mechanical - Rough In |
|
Matt Forsyth |
4/1/2021 |
Passed: Plumbing/Gas - Tub Set/Shower Pan |
|
Matt Forsyth |
4/1/2021 |
Cancelled: Electrical - Temporary Service |
|
Matt Forsyth |
4/1/2021 |
Passed: Building - Insulation |
Walls Only |
Matt Forsyth |
5/4/2021 |
Failed: Building - Framing |
Garage Door Header Still Not Built To The Design |
Matt Forsyth |
5/4/2021 |
Failed: Electrical - Permanent Power |
Ground Rods Need To Be Drove Down Below Finished Dirt Grade Elevation. Electrical Conduit Pipe Not Installed In Meter Can |
Matt Forsyth |
5/24/2021 |
Cancelled: Electrical - Temporary Service |
|
Matt Forsyth |
5/24/2021 |
Septic Release Inspection |
|
Health Dept |
5/27/2021 |
Failed: Electrical - Permanent Power |
Need Letter For Garage Door. (engineering ) Mforsyth@columbiacountyfla.com |
Matt Forsyth |
6/10/2021 |
Failed: Building - Framing |
Garage Header Was Closed Off So Could Not See Strapping. Need As Built Letter From Engineer Stating Work Was Done As Designed Are Tear Drywall Back Off 4 Inspection. Service Entrance Conduit Not Built To Metercan Ground Rods Need To Be Below Grade Along With Bare Copper Wire. Next Failed Inspection Will Be Charged Re Inspection Fee.3866230168 Matt |
Matt Forsyth |
6/11/2021 |
Failed: Electrical - Permanent Power |
Conduit Not Running 2 Meter Can |
Matt Forsyth |
6/11/2021 |
Rescheduled 6/21/2021:Electrical - Permanent Power |
|
Matt Forsyth |
6/17/2021 |
Passed: Electrical - Permanent Power |
|
Matt Forsyth |
6/21/2021 |
Release to power company |
|
Matt Forsyth |
6/21/2021 |
Passed: Building - Framing |
|
Matt Forsyth |
6/21/2021 |
Release to power company |
Changed Poweer Company From Fpl To Clay Electric |
Melissa Garber |
6/24/2021 |
Passed: Building - Final |
|
Matt Forsyth |
7/2/2021 |