Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 315 SW STILLVIEW GLN
FORT WHITE, FL 32038
Parcel #: 03815-117
Acres: 10.01
Owner: Reddoch Russell Ware & Lor Ruth
Subdivision: Cardinal Farms - Division Of Land
Zoning: A-3
Flood Zone: X
District: 4
Application #: 47520
Permit #: 000040873
Related Permit:
Submitted: Thursday, October 15, 2020
Issued: Tuesday, November 10, 2020
Expires: Monday, July 26, 2021
Completed: Monday, July 26, 2021
Status: Completed
Septic Release? Yes
Notes:
BLOWER DOOR TEST RESULTS 2.55, MECHANICAL VENTILATION REQUIRED 7.20.2021
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 86'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0485C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2093
Total Area (Sqft) 3203
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 20-0811
Review Notes
10/14/2020 Application pending.
10/15/2020 Point Review - Printed-Online Application
10/26/2020 Zoning Review - Reviewed
10/26/2020 Plan Review - Reviewed
10/26/2020 Final Review - Documents Required
10/30/2020 Final Review - Documents Required
11/10/2020 Final Review - Documents Required
11/10/2020 Permit Issued
5/24/2021 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Bryan Zecher
Bryan Zecher Construction Inc
CBC054575 Cert.building Contractor Contractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Anthony R Franks
Franks & Lane Heating And Air Llc
CAC1818631 Cert. A/c Class “b” Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Robert Ogles Ii
Ogles Roofing & Construction Llc
CCC1328699 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 11/17/2020
Passed: Building - Footer Matt Forsyth 12/10/2020
Passed: Engineering - Setbacks Matt Forsyth 12/10/2020
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 1/11/2021
Passed: Building - Slab Troy Crews 2/1/2021
Cancelled: Building - Wall Sheathing Anthony Aslan 2/18/2021
Passed: Building - Ext Strapping/Wall Sheathing Anthony Aslan 2/18/2021
Passed: Building - Roof Decking Anthony Aslan 2/18/2021
Cancelled: Building - Ext Strapping/Wall Sheathing Troy Crews 2/18/2021
Cancelled: Building - Roof Decking Troy Crews 2/18/2021
Failed: Building - Framing Need Correct Truss Plans. Anthony Aslan 2/22/2021
Passed: Building - Framing Anthony Aslan 2/24/2021
Cancelled: Plumbing/Gas - 1st Underground Rough–In Wrong Inspection Anthony Aslan 3/18/2021
Passed: Plumbing/Gas - 2nd Rough-In Gauge Was Faulty Pressure, Pressure Present Have Gauge When Next Rough Inspections. Anthony Aslan 3/19/2021
Passed: Electrical - 2nd Rough-In Anthony Aslan 3/24/2021
Passed: Mechanical - Rough In Anthony Aslan 3/24/2021
Passed: Building - Insulation Observed No Pressure On Water Gauge Anthony Aslan 4/5/2021
Passed: Electrical - Permanent Power Anthony Aslan 5/26/2021
Release to power company Anthony Aslan 5/26/2021
Failed: Building - Final Need Blower Door Report, Rec'd 7.20.21 @ 2.55, Mech Ventilation Req'd Anthony Aslan 7/19/2021
Passed: Building - Final Rec'd Picture Of Fresh Air Anthony Aslan 7/26/2021