Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 315 SW STILLVIEW GLN
FORT WHITE, FL 32038
Parcel #: 03815-117
Acres: 10.01
Owner: Reddoch Russell Ware & Lor Ruth
Subdivision: Cardinal Farms - Division Of Land
Zoning: A-3
Flood Zone: X
District: 4
Application #: 47520
Permit #: 000040873
Related Permit:
Submitted: Thursday, October 15, 2020
Issued: Tuesday, November 10, 2020
Expires: Monday, July 26, 2021
Completed: Monday, July 26, 2021
Status: Completed
Septic Release? Yes
Notes:
BLOWER DOOR TEST RESULTS 2.55, MECHANICAL VENTILATION REQUIRED 7.20.2021
Job Details
Elevation regulation Subdivision Plat
Finished floor requirement 86'
Requirement needed By Nailing Inspection
Document needed is a Surveyor letter giving the Finished Floor Elevation
Document receieved Yes
Fema map number 12023C0485C
In floodway N
This is the construction of a Single Family Dwelling
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Stories 1
Heated Area (Sqft) 2093
Total Area (Sqft) 3203
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 20-0811
Review Notes
10/14/2020 Application pending.
10/15/2020 Point Review - Printed-Online Application
10/26/2020 Zoning Review - Reviewed
10/26/2020 Plan Review - Reviewed
10/26/2020 Final Review - Documents Required
10/30/2020 Final Review - Documents Required
11/10/2020 Final Review - Documents Required
11/10/2020 Permit Issued Permit #000040873 created and approved.
5/24/2021 Final Review - Payment Needed NEEDED: ENVIRONMENTAL HEALTH ONLY BELOW ALL COMPLETE: PLANS UPLOEADED ARE A FULL SET SHEETS 1-15 = (ARCHITECTUAL PLANS INCLUDE SHEETS - 5, 5.1, 6, 6A, 6B, 7, 8, 8.1) (SEALED STRUCTURAL PLANS INCLUDE SHEETS - S0.0, S0.1, S1.0, S1.01, S1.1 - WHICH IS 1-7 OF 15) = TOGETHER THIS MAKES 15 SHEETS TOTAL.
Contractors
Name/ Business License Title Role
Bryan Zecher
Bryan Zecher Construction Inc
CBC054575 Cert.building Contractor Contractor
Marcus Matthews
Matthews Electric Llc
EC13005459 Electrical Contractor Subcontractor
Anthony R Franks
Franks & Lane Heating And Air Llc
CAC1818631 Cert. A/c Class “b” Subcontractor
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Robert Ogles Ii
Ogles Roofing & Construction Llc
CCC1328699 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Septic Release Inspection Health Dept 11/17/2020
Passed: Building - Footer Matt Forsyth 12/10/2020
Passed: Engineering - Setbacks Matt Forsyth 12/10/2020
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 1/11/2021
Passed: Building - Slab Troy Crews 2/1/2021
Cancelled: Building - Wall Sheathing Anthony Aslan 2/18/2021
Passed: Building - Ext Strapping/Wall Sheathing Anthony Aslan 2/18/2021
Passed: Building - Roof Decking Anthony Aslan 2/18/2021
Cancelled: Building - Ext Strapping/Wall Sheathing Troy Crews 2/18/2021
Cancelled: Building - Roof Decking Troy Crews 2/18/2021
Failed: Building - Framing Need Correct Truss Plans. Anthony Aslan 2/22/2021
Passed: Building - Framing Anthony Aslan 2/24/2021
Cancelled: Plumbing/Gas - 1st Underground Rough–In Wrong Inspection Anthony Aslan 3/18/2021
Passed: Plumbing/Gas - 2nd Rough-In Gauge Was Faulty Pressure, Pressure Present Have Gauge When Next Rough Inspections. Anthony Aslan 3/19/2021
Passed: Electrical - 2nd Rough-In Anthony Aslan 3/24/2021
Passed: Mechanical - Rough In Anthony Aslan 3/24/2021
Passed: Building - Insulation Observed No Pressure On Water Gauge Anthony Aslan 4/5/2021
Passed: Electrical - Permanent Power Anthony Aslan 5/26/2021
Release to power company Anthony Aslan 5/26/2021
Failed: Building - Final Need Blower Door Report, Rec'd 7.20.21 @ 2.55, Mech Ventilation Req'd Anthony Aslan 7/19/2021
Passed: Building - Final Rec'd Picture Of Fresh Air Anthony Aslan 7/26/2021
Documents
File Name Date File Size
Power Release-electrical-permanent Power 20210526.pdf 2025.07.05 11.59kB
Original Permit 20201110.pdf 2025.07.05 28.45kB
Manual J Forms 47520 2020-10-26 08.26.59.128.pdf 2025.06.22 61.39kB
Property Appraiser Parcel Details Printed Page 20201014 165028.pdf 2025.06.22 119.20kB
Surveyor Letter Giving The Finished Floor Elevation 20210401 022546.pdf 2025.06.22 87.91kB
Backup Material 20201026 084147.pdf 2025.06.22 135.89kB
911 Address Form 20201014 165027.pdf 2025.06.22 183.97kB
Energy Code Forms 47520 2020-10-26 08.26.52.143.pdf 2025.06.22 400.93kB
Product Approval Code Specifications Form 20201014 165130.pdf 2025.06.22 502.34kB
Russell-reddoch Eh 2020-11-10 15.18.11.292.pdf 2025.06.22 507.06kB
Subcontractor Form 20201014 165130.pdf 2025.06.22 531.92kB
Owner And Contractor Signature Page 20201015 163200.pdf 2025.06.22 654.72kB
Cardinal Farms - Division Of Land Lot 17 2020-10-26 08.26.44.878.pdf 2025.06.22 658.77kB
Architectural Plans 20201014 165027.pdf 2025.06.21 1.18MB
Approved Architectural Plans 20201026 115619.pdf 2025.06.21 1.18MB
Bdt Permit 40872 2021-07-20 07.26.08.437.pdf 2025.06.21 280.68kB
Site Plan 20201020 083659.pdf 2025.06.21 440.10kB
Residential Or Commercial Checklist 20201020 084132.pdf 2025.06.21 2.72MB
Win_20210201_16_03_25_pro 2021-02-01 16.05.02.256.jpg 2025.06.20 91.68kB
40873 Fresh Air Damper 2021-07-26 14.19.06.34.jpg 2025.06.20 114.41kB
Structural Engineering And Wind Load Calculations 20201024 090551.pdf 2025.06.20 3.79MB
Approved Structural Plans 47520 2020-10-26 09.04.56.20.pdf 2025.06.19 10.24MB
Certificate Of Occupancy 20210726.pdf 2021.07.26 62.24kB
Reddoch Final Layout 40873 2021-02-23 14.00.50.721.pdf 2021.02.23 35.60kB
Correct Truss 40873 2021-02-23 13.50.39.950.pdf 2021.02.23 2.01MB
Reddoch Noc 2020-10-20 11.49.32.598.tiff 2020.10.20 122.21kB
Recorded Deed 20201015 163201.pdf 2020.10.15 104.28kB