Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 200 NW ANSLEY PL
LAKE CITY, FL 32055
Parcel #: 02202-116
Acres: 4.21
Owner: Tatum Tymber Lee
Subdivision: High Pointe
Zoning: PRRD
Flood Zone: X
District: 3
Application #: 47354
Permit #: 000040771
Related Permit: Culvert: 000040772
Submitted: Wednesday, September 23, 2020
Issued: Thursday, October 22, 2020
Expires: Wednesday, August 11, 2021
Completed: Wednesday, August 11, 2021
Status: Completed
Septic Release? Yes
Notes:
LOMA ON FILE - FLOOD ZONE X HOME BEING BUILT BETWEEN LOTS 15 & 16, WHICH COMBINES THESE LOTS AND CAN NOT BE SEPARATED OR PORTIONS DEEDED OFF OF EITHER LOT.
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 3445
Total Area (Sqft) 5337
Stories 1
Building Height 13
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 30'
Setback Side 1 25'
Setback Side 2 25'
Setbacks Rear 25'
Septic# (00-0000) or (X00-000) 20-0804
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0280D
In floodway N
Review Notes
9/23/2020 Application pending.
9/23/2020 Point Review - Printed-Online Application
9/25/2020 Zoning Review - Reviewed
9/25/2020 Zoning Review - Reviewed
10/5/2020 Plan Review - Corrections Needed
10/8/2020 Plan Review - Documents Required
10/20/2020 Plan Review - Reviewed
10/20/2020 Zoning Review - Reviewed
10/21/2020 Final Review - Payment Needed
10/22/2020 Permit Issued Permit #000040771 created and approved.
7/2/2021 Final Review - Payment Needed NEED ENVIRONMENTAL HEALTH SIGNED SITE PLAN APPROVAL -386.758.1058 - REC'D. 10.21.20 "NO VISIBILE ENGINEER SEAL ON PLANS NOR WIND LOAD.....(???) PLANS NEED TO BE SEALED-- REC'D 10/13/2020
Contractors
Name/ Business License Title Role
David E Hall
David Hall's Air Cond & Heating Svc,inc.
Liability Insurance Expired.
CAC057424 Class B A/c Contractor Subcontractor
David Wood
Wood's Electrical Services Inc
Workers Comp & Employees Workers Comp Expired.
EC13002213 Electrical Contractor Subcontractor
Roger D Whiddon
Whiddon Construction Co Inc
CCC1330273 Roofing Contractor Subcontractor
Matthew Hentzelman
Trademark Construction Group, Inc.
County License & State License Expired.
CCC1329208 Roofing Contractor Contractor
Inspections
Inspection Notes Performed By Date
Passed: Engineering - Initial Driveway Mccormick, David 10/23/2020
Failed: Electrical - Temporary Service Wire Not Sized For 30amp Breaker Matt Forsyth 11/6/2020
Passed: Building - Footer Matt Forsyth 11/10/2020
Passed: Engineering - Setbacks Matt Forsyth 11/10/2020
Passed: Electrical - Temporary Service Matt Forsyth 11/10/2020
Release to power company Matt Forsyth 11/10/2020
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 12/2/2020
Passed: Building - Slab Matt Forsyth 12/16/2020
Passed: Building - Lintel/Tie Beam Matt Forsyth 1/6/2021
Rescheduled 3/11/2021:Building - Roof Decking Matt Forsyth 3/11/2021
Passed: Building - Roof Decking Matt Forsyth 3/11/2021
Passed: Building - Framing Matt Forsyth 4/14/2021
Passed: Electrical - 2nd Rough-In Matt Forsyth 4/14/2021
Passed: Mechanical - Rough In Matt Forsyth 4/14/2021
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 4/14/2021
Rescheduled 4/20/2021:Building - Insulation Matt Forsyth 4/19/2021
Passed: Building - Insulation Matt Forsyth 4/20/2021
Septic Release Inspection Health Dept 6/21/2021
Passed: Engineering - Final Driveway Mccormick, David 7/2/2021
Passed: Electrical - Permanent Power Need Driveway Release To Release Power Matt Forsyth 7/2/2021
Passed: Electrical - Permanent Power Matt Forsyth 7/2/2021
Release to power company Matt Forsyth 7/2/2021
Passed: Building - Final Matt Forsyth 8/11/2021
Documents
File Name Date File Size
Approved Trusses 47354 2020-10-20 13.53.56.659.pdf 2023.12.26 3.09MB
High_pointe Lots 15_16 2020-10-20 16.40.09.772.pdf 2023.12.26 7.06MB
Residential Or Commercial Checklist 20200924 100114.pdf 2023.12.26 592.95kB
Original Permit 20201022.pdf 2023.12.26 42.88kB
911 Address Form 20200923 163437.pdf 2023.12.26 8.56MB
Loma 20-04-3321a.pdf 2023.12.26 95.59kB
Structural Engineering And Wind Load Calculations 20200923 162947.pdf 2023.12.26 1.55MB
Septic Approval Paperwork 20201021 051647.pdf 2023.12.26 507.39kB
Win_20210811_10_19_23_pro 2021-08-11 10.23.44.772.jpg 2023.12.26 139.27kB
Product Approval Code Specifications Form 20200924 100114.pdf 2023.12.26 144.82kB
Manual J Forms 20200923 162946.pdf 2023.12.26 65.43kB
Win_20201216_11_17_11_pro 2020-12-16 11.17.12.385.jpg 2023.12.26 156.80kB
Structural Engineering And Wind Load Calculations 20201013 171729.pdf 2023.12.26 2.03MB
Architectural Plans 20201013 171728.pdf 2023.12.26 5.37MB
Owner And Contractor Signature Page 20200923 162140.pdf 2023.12.26 1.79MB
Site Plan 20200923 162946.pdf 2023.12.26 132.58kB
Certificate Of Occupancy 20210811.pdf 2023.12.26 69.12kB
Recorded Deed 20200923 162141.pdf 2023.12.26 67.30kB
Architectural Plans 20200923 162944.pdf 2023.12.26 5.05MB
Terrell Noc 2020-11-04 16.00.19.125.pdf 2023.12.26 87.87kB
Subcontractor Form 20200924 100114.pdf 2023.12.26 66.09kB
Approved Plans 47354 2020-10-20 13.59.59.986.pdf 2023.12.26 5.41MB
Energy Code Forms 20200923 162945.pdf 2023.12.26 341.87kB
Approved Truss Plans 47354 2020-10-05 08.29.46.177.pdf 2023.12.26 3.10MB
Truss Engineering 20200923 162947.pdf 2023.12.26 2.88MB
Backup Material 20201020 044346.pdf 2023.12.26 241.24kB
Win_20210811_10_17_16_pro 2021-08-11 10.22.07.674.jpg 2023.12.26 120.54kB
Power Release-electrical-temporary Service 20201110.pdf 2023.12.26 38.84kB
Well Letter.pdf 2023.12.26 727.44kB
Power Release-electrical-permanent Power 20210702.pdf 2023.12.26 39.08kB