Permit Details

Permit Search

Permit

New Residential Construction

926 SW LITTLE RD
LAKE CITY, FL 32024

Permit #
000039967
Application #
46272
Status Completed
  1. Submitted —
  2. Issued Jun 17, 2020
  3. Expires Sep 7, 2021
  4. Completed Mar 11, 2021

Property

Parcel #
03401-109
Owner
Soto Guadalupe G
Acres
4.01
Subdivision
Rivers Manor Unit 1
Zoning
A-3
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0383D
This is the construction of a
Single Family Dwelling
Stories
1
Heated Area (Sqft)
1162
Total Area (Sqft)
1162
Building Height
17
Septic# (00-0000) or (X00-000)
20-0443
Setbacks Front
30
Setback Side 1
25
Setback Side 2
25
Setbacks Rear
25
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
single family
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code

Status & Review History

  1. Application pending.
  2. Point Review - Processing
  3. Point Review - Documents Required
  4. Zoning Review - Reviewed
  5. Plan Review - Reviewed
  6. Final Review - Documents Required
  7. Final Review - Complete
  8. Final Review - Payment Needed
  9. Permit Issued

Contractors

  • Isaiah Cully

    Ic Construction Llc

    License
    CBC1259655
    Title
    Building Contractor
    Role
    Contractor
  • Cody Barrs

    Barrs Plumbing Inc

    License
    CFC1427145
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Tyler M Turner

    Tmt Roofing Llc

    License
    CCC1330410
    Title
    Cert Roofing
    Role
    Subcontractor
  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor

Inspections

  1. Jun 15, 2020

    Septic Release Inspection

    Inspected by Health Dept

  2. Aug 13, 2020

    Passed: Building - Footer

    Inspected by Matt Forsyth

  3. Aug 13, 2020

    Passed: Engineering - Setbacks

    Inspected by Matt Forsyth

  4. Aug 31, 2020

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  5. Sep 2, 2020

    Failed: Building - Slab

    Contractor Needs To Meet With Owner Regarding Slab Height And Porches

    Inspected by Troy Crews

  6. Sep 3, 2020

    Rescheduled 9/3/2020:Building - Slab

    Inspected by Troy Crews

  7. Sep 3, 2020

    Rescheduled 9/4/2020:Building - Slab

    Inspected by Troy Crews

  8. Sep 4, 2020

    Passed: Building - Slab

    Contractor Is To Form Up And Pour This Slab 12 Inches Above Existing Stem Wall

    Inspected by Troy Crews

  9. Oct 5, 2020

    Passed: Building - Wall Sheathing

    Beware Of Very Aggressive Dog

    Inspected by Matt Forsyth

  10. Nov 3, 2020

    Passed: Electrical - 2nd Rough-In

    Inspected by Matt Forsyth

  11. Nov 3, 2020

    Passed: Mechanical - Rough In

    Inspected by Matt Forsyth

  12. Nov 3, 2020

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Matt Forsyth

  13. Dec 3, 2020

    Passed: Building - Insulation

    Inspected by Troy Crews

  14. Mar 5, 2021

    Failed: Building - Final

    Need Final Termite Treatment

    Inspected by Matt Forsyth

  15. Mar 11, 2021

    Passed: Building - Final

    Inspected by Matt Forsyth

Documents