Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 136 SW GOVERNORS GLN
LAKE CITY, FL 32024
Parcel #: 03406-208
Acres: 2.50
Owner: Handy Bradley R & Kelli
Subdivision: Rose Creek Plantation Phase 1
Zoning: A-3
Flood Zone: X
District: 5
Application #: 45943
Permit #: 000039655
Related Permit: Culvert Waiver: 000039656
Submitted:
Issued: Wednesday, April 22, 2020
Expires: Friday, May 28, 2021
Completed: Friday, May 28, 2021
Status: Completed
Septic Release? Yes
Notes:
LEGAL LOT OF RECORD
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 4549
Total Area (Sqft) 5779
Stories 2
Building Height 34
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Septic# (00-0000) or (X00-000) 20-0269
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0383D
In floodway N
Review Notes
4/9/2020 Point Review - Received
4/22/2020 Plan Review - Status Cleared
4/22/2020 Plan Review - Completed/Sent for Zoning Review
4/22/2020 Zoning Review - Completed/Sent for Final Review
4/22/2020 Permit Issued Permit #000039655 created and approved.
4/1/2021 Final Review - Payment Needed
Contractors
Name/ Business License Title Role
Isaiah Cully
Ic Construction Llc
CBC1259655 Building Contractor Contractor
Everton D Ruddock
D&s Lighting Inc
EC13003800 Electrical Contractor Subcontractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Cody Barrs
Barrs Plumbing,inc.
CFC1427145 Plumbing Contractor Subcontractor
Tyler M Turner
Tmt Roofing Llc
CCC1330410 Cert Roofing Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Tommy Matthews 5/8/2020
Passed: Engineering - Setbacks Tommy Matthews 5/8/2020
Failed: Electrical - 1st Underground Rough–In Need Me Notarize Letter From Plumber For Underground Work Matt Forsyth 5/29/2020
Passed: Building - Slab Matt Forsyth 6/3/2020
Passed: Electrical - Temporary Service Matt Forsyth 6/3/2020
Release to power company Matt Forsyth 6/3/2020
Passed: Building - Ext Strapping/Wall Sheathing Wall Sheeting Only Ok To Cover Matt Forsyth 7/17/2020
Passed: Building - Roof Decking Matt Forsyth 7/17/2020
Passed: Building - Framing Need Safety Railing On Stairway Matt Forsyth 8/3/2020
Passed: Electrical - 2nd Rough-In Matt Forsyth 9/21/2020
Passed: Mechanical - Rough In Matt Forsyth 9/21/2020
Passed: Plumbing/Gas - 2nd Rough-In Need Nail Plates For Gas Line Two Places Matt Forsyth 9/21/2020
Passed: Building - Insulation Matt Forsyth 10/5/2020
Septic Release Inspection Health Dept 3/16/2021
Failed: Electrical - Permanent Power No Work Inside Until Proper Safety Railing Installed Matt Forsyth 4/5/2021
Passed: Electrical - Permanent Power Safety Railing Installed Matt Forsyth 4/6/2021
Release to power company Matt Forsyth 4/6/2021
Failed: Building - Final Front Door Gfci Not Correct, Upstairs West Bathroom Gfci Not Correct, Cabinets Not Complete Could Not Test Kitchen Gfci Plugs, Small Deck At Rear Patio Will Need To Be Tapered 2inch Step Up, 4inches Is Minimum Step, Need Blower Door Test, Also Stair Guardrail Not Complete Troy Crews 5/26/2021
Passed: Building - Final Matt Forsyth 5/28/2021