Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 6046 SE COUNTY ROAD 252
LAKE CITY, FL 32025
Parcel #: 10513-008
Acres: 5.12
Owner: Wilburn & Sylvia Fender
Subdivision: High Falls Unr
Zoning: A-3
Flood Zone: X
District: 4
Application #: 44681
Permit #: 000039491
Related Permit:
Submitted:
Issued: Thursday, March 19, 2020
Expires: Monday, September 14, 2020
Completed: Monday, September 14, 2020
Status: Completed
Septic Release? Yes
Notes:
EACH 5 AC LOT IS LEGAL LOT OF RECORD, HOUSE LOCATED OUT OF A ZONE PER SITE PLAN
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1715
Total Area (Sqft) 2763
Stories 1
Building Height 19
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Septic# 20-0168
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0410C
In floodway N
Review Notes
3/19/2020 Permit Issued Permit #000039491 created and approved.
Contractors
Name/ Business License Title Role
Douglas Edgley
Cee-bas Incorporated Dba Edgley Construction Company
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CRC1330689 Residential Contractor Contractor
Matthew H Burns
Matt Burns Electric, Inc.
EC13006531 Electrical Contractor Subcontractor
David E Hall
David Hall's Air Cond & Heating Svc,inc.
Liability Insurance Expired.
CAC057424 Class B A/c Contractor Subcontractor
Don C Bills Sr
Hometown Plumbing Services Llc
Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CFC1428890 Plumbing Contractor Subcontractor
Darin L Summerlin
Summerlin Roofing,inc.
Employees Workers Comp Expired.
CCC1326192 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Tommy Matthews 3/27/2020
Release to power company Tommy Matthews 3/27/2020
Passed: Building - Footer Tommy Matthews 3/31/2020
Passed: Engineering - Setbacks Tommy Matthews 3/31/2020
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 4/13/2020
Passed: Building - Slab Troy Crews 4/16/2020
Passed: Building - Wall Sheathing Troy Crews 4/28/2020
Passed: Building - Roof Decking Troy Crews 5/11/2020
Passed: Building - Framing Letter Coming For Back Porch Headers Troy Crews 5/29/2020
Passed: Electrical - 1st Underground Rough–In Troy Crews 5/29/2020
Passed: Mechanical - Rough In Troy Crews 5/29/2020
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 5/29/2020
Passed: Building - Insulation Troy Crews 6/8/2020
Passed: Electrical - Permanent Power Need Septic Approval Tommy Matthews 7/24/2020
Release to power company Rec'd. Eh Tommy Matthews 7/29/2020
Septic Release Inspection Need To Pay Assessment Fees Before Co Is Released Health Dept 7/30/2020
Passed: Building - Final Troy Crews 9/14/2020