Permit Details

Permit Search

Permit

Mobile Home

161 SW ARMAND PLACE
LAKE CITY, FL 32024

Permit #
000039417
Application #
44528
Status Completed
  1. Submitted —
  2. Issued Mar 9, 2020
  3. Expires Nov 3, 2020
  4. Completed May 7, 2020

Property

Parcel #
09340-051
Owner
Conley Dennis E & Ann G
Acres
0.72
Subdivision
Mason City
Zoning
A-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0415C
Mobile Home is a:
Double Wide
Year Built
2016
Width (Ft.In)
32
Length (Ft.In)
76
Driveway access to home:
Culvert Permit
Installation Decal #
64756
Septic #
20-0117
Setbacks Front
30
Setback Side 1
25
Setbacks Rear
25
Dev Permit #
F023-
Setback Side 2
25
Are you applying for a 5 year temporary permit?
No
Serial #
flthlct3242g-2961ab
Wind Zone?
2
Residential or Commercial Use?
Residential

Status & Review History

  1. Zoning Review - Completed/Sent for Final Review
  2. Permit Issued

Contractors

  • James Foley

    Foley Mobile Home Transport

    License
    IH1078536
    Title
    Mh Installer (ih)
    Role
    Contractor

    County License & State License Expired.

  • Richard H Sapp

    Ace Electric Inc Of North Florida

    License
    EC13006007
    Title
    Electrical Contractor
    Role
    Subcontractor

    County License & State License Expired.

  • Ronald Bonds, Sr.

    Style Crest Inc

    License
    CAC1817658
    Title
    Class "b" A/c Contractor
    Role
    Subcontractor

    County License & State License Expired.

Inspections

  1. Mar 2, 2020

    Passed: Mobile Home - In County Pre-Mobile Home before set-up

    Inspected by Troy Crews

  2. May 7, 2020

    Release to power company

    Inspected by Laurie Hodson

  3. May 7, 2020

    Certificate-Release Certificate

    Inspected by Tommy Matthews

  4. May 7, 2020

    Passed: Mobile Home - Mobile Home Set-Up Final

    Need Septic Release.

    Inspected by Tommy Matthews

  5. May 7, 2020

    Passed: Engineering - Setbacks

    Inspected by Tommy Matthews

  6. May 7, 2020

    Septic Release Inspection

    Inspected by Health Dept