New Residential Construction Permit

Address 21839 SW STATE ROAD 47
FORT WHITE, FL 32038
Parcel #: 04232-011
Acres:2.00
Owner:Donald & Jane Wilkinson
Subdivision:
Zoning:A-3
Flood Zone:X
District:2
Application #:44410
Permit #: 000039288
Related Permit:
Submitted:
Issued:Wednesday, February 12, 2020
Expires:Wednesday, September 23, 2020
Completed:Wednesday, September 23, 2020
Status: Completed
Septic Release? Yes

Notes

DEED CONFIRMING LOT OF RECORD 1983 ORB BK 529 PG 521, ENGINEER LETTER PROVIDED - THE MINIMUM FINISHED FLOOR ELEVATION IS 55.50' AND A SWALE GRADED UPHILL OF THE HOME TO PREVENT DIRECT RUNOFF IMPACTING THE HOME, ELEVATION CONFIRMATION LETTER BY SURVEYOR AT SLAB REQUIRED. ON 9.14.20 AN ELEVATION CONFIRMATION LETTER REC'D AT 57.1'.

Job Details

Finished floor requirement 1' ABOVE ROAD
Fema map number 12023C0488C
This is the construction of a Single Family Dwelling
Setbacks Front 30
Setback Side 1 25
Setback Side 2 25
Setbacks Rear 25
Stories 1
Heated Area (Sqft) 1417
Total Area (Sqft) 1885
Building Height 16
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title Single family
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 20-0078

Review Notes

1/31/2020 Zoning Review - On Hold
2/3/2020 Zoning Review - Completed/Sent for Final Review
2/12/2020 Permit Issued

Contractors

Name / Business License Title Role

Inspections

Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Need Porti Potti On Site Before Next Inspection. Tommy Matthews 2/25/2020
Passed: Building - Monolithic Slab Tommy Matthews 3/10/2020
Passed: Engineering - Setbacks Tommy Matthews 3/10/2020
Passed: Electrical - Temporary Service Need Elevation Letter Asap. Tommy Matthews 3/24/2020
Release to power company Tommy Matthews 3/24/2020
Passed: Building - Framing Matt Forsyth 4/7/2020
Passed: Electrical - 2nd Rough-In Tommy Matthews 5/8/2020
Passed: Mechanical - Rough In Tommy Matthews 5/8/2020
Passed: Plumbing/Gas - Tub Set/Shower Pan Tommy Matthews 5/8/2020
Passed: Plumbing/Gas - 2nd Rough-In Tommy Matthews 5/8/2020
Septic Release Inspection Health Dept 5/13/2020
Failed: Building - Insulation Holes Where Electrical Wire Goes Through Top Plate Need To Be Sealed In All Locations. Tommy Matthews 5/29/2020
Passed: Building - Insulation Troy Crews 6/1/2020
Failed: Electrical - Permanent Power Must Have Elevation Confirmation From Surveyor Prior To Any More Inspections. Britt Is Working On This 9.11.20-lh - Letter Rec'd 9.14.20 Troy Crews 8/19/2020
Passed: Electrical - Permanent Power Matt Forsyth 9/14/2020
Release to power company Matt Forsyth 9/14/2020
Failed: Building - Final Need Blower Door Test And Final Termite Treatment Matt Forsyth 9/22/2020
Passed: Building - Final Matt Forsyth 9/23/2020

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.