Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Commercial Construction Permit
Address 177 NW KNIGHTS AVE
LAKE CITY, FL 32055
Parcel #: 02545-101
Acres: 2.03
Owner: Kaveps Lake City Llc
Subdivision: Corner At Commerce Blvd
Zoning: CHI
Flood Zone: X
District: 3
Application #: 43807
Permit #: 000039128
Related Permit:
Submitted: Tuesday, October 15, 2019
Issued: Wednesday, January 8, 2020
Expires: Thursday, May 21, 2020
Completed: Thursday, May 21, 2020
Status: Completed
Septic Release? Yes
Notes:
SDP 19 09 APPROVED 8/22/19, MINIMUM FLOOR ELEVATION - SITE & DEVELOPMENT PLAN 158.75', NEED ELEVATION CONFIRMATION LETTER FROM SURVEYOR AT SLAB, PERMIT INCLUDES FIRE PROTECTION SYSTEM ELEVATION LETTER RECEIVED 158.75
Job Details
This is the construction of a: TEXAS ROADHOUSE RESTAURANT
Heated Area (Sqft) 7908
Total Area (Sqft) 7908
Stories 1
Building Height 27.5
Driveway access to property: Existing Drive
Is there a Fire Sprinkler System? Yes
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Assembly
Occupancy Use Title (A-2) RESTAURANT
Design Occupant Load 409
Setbacks Front 20
Setback Side 1 5
Setback Side 2 5
Setback Rear 15
Septic# (00-0000) or (X00-000) X-CITY
Dev Permit # F023-
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Fema map number 12023C0290D
Review Notes
10/15/2019 Point Review - Received
12/30/2019 Zoning Review - Completed/Sent for Final Review
1/8/2020 Permit Issued Permit # created and approved.
8/4/2022 City of Lake City Notified of Application within Utility Service Areas LC_GAS, LC_WATER, LC_SEWER.
Contractors
Name/ Business License Title Role
Michael J Wasserman
Wasserman Construction Company Llc
County License & State License Expired.
CGC042128 Cert. General Contractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Troy Crews 1/23/2020
Passed: Engineering - Setbacks Troy Crews 1/23/2020
Passed: Building - Footer Cooler Pre Slab Troy Crews 1/24/2020
Passed: Engineering - Setbacks Troy Crews 1/24/2020
Passed: Plumbing/Gas - 1st Underground Rough–In Troy Crews 1/30/2020
Passed: Building - Slab East Half Troy Crews 2/4/2020
Passed: Electrical - 1st Underground Rough–In Troy Crews 2/4/2020
Passed: Electrical - Temporary Service Existing Pole Troy Crews 2/4/2020
Release to power company Troy Crews 2/4/2020
Passed: Building - Slab West Half Troy Crews 2/5/2020
Passed: Building - Footer Front Entry Columns And Dumpster Gate Post Footers Troy Crews 2/6/2020
Passed: Engineering - Setbacks Troy Crews 2/6/2020
Passed: Building - Roof Decking Troy Crews 2/19/2020
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 2/19/2020
Passed: Mechanical - Rough In Curbs For Rooftop Units Troy Crews 2/21/2020
Passed: Building - Roof Decking Front Dining Area Troy Crews 2/24/2020
Passed: Electrical - 1st Underground Rough–In Pole Bases Troy Crews 2/24/2020
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 2/26/2020
Passed: Electrical - 2nd Rough-In Kitchen And Bathroom Area Troy Crews 2/28/2020
Passed: Building - Insulation Partial Kitchen Area Troy Crews 3/2/2020
Passed: Electrical - 2nd Rough-In Half Walls Front Area Troy Crews 3/2/2020
Passed: Building - Framing Front Bar Area Tv Walls Troy Crews 3/3/2020
Passed: Building - Insulation Partial Bathrooms And Back Wall Troy Crews 3/3/2020
Passed: Building - Insulation Front Walls Troy Crews 3/4/2020
Passed: Mechanical - Rough In Kitchen Area Rough In For Insulation Troy Crews 3/11/2020
Rescheduled 3/23/2020:Mechanical - Rough In Troy Crews 3/20/2020
Passed: Mechanical - Rough In Front Dining Area Troy Crews 3/23/2020
Rescheduled 3/24/2020:Building - Lintel/Tie Beam Troy Crews 3/23/2020
Rescheduled 3/25/2020:Building - Lintel/Tie Beam Troy Crews 3/24/2020
Passed: Building - Lintel/Tie Beam Dumpster Enclosure Troy Crews 3/25/2020
Passed: Electrical - Permanent Power Troy Crews 4/7/2020
Release to power company Troy Crews 4/7/2020
Passed: Plumbing/Gas - 2nd Rough-In Main Gas Line Has Pressure Test Troy Crews 4/7/2020
Cancelled: Fire - Operational Test - Sprinkler/Standpipe Contractor Canceled And Did Not Reschedule Laurie Hodson 4/17/2020
Passed: Fire - Underground Main - Visual Tad Cervantes 4/17/2020
Passed: Fire - Light Test Tad Cervantes 4/17/2020
Passed: Electrical - Above Ceiling Troy Crews 4/21/2020
Passed: Mechanical - Above Ceiling Open Ceiling Areas Ready For Tiles Troy Crews 4/21/2020
Passed: Fire - Fire Final Tad Cervantes 4/22/2020
Passed: Building - Final Troy Crews 5/18/2020
Passed: Engineering - Zoning Final Brandon Stubbs 5/21/2020
(Requested) Fire-Kitchen Hood – Fire Suppression Test
(Requested) Fire-Operational Test - Alarm System