Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 172 SW BEACON WAY
LAKE CITY, FL 32025
Parcel #: 02951-103
Acres: 0.50
Owner: Amelia Landing Inc
Subdivision: Amelia Landing Phase 1
Zoning: PRD
Flood Zone: X
District: 5
Application #: 44266
Permit #: 000039114
Related Permit:
Submitted:
Issued: Monday, January 6, 2020
Expires: Monday, September 28, 2020
Completed: Monday, September 28, 2020
Status: Completed
Septic Release? Yes
Notes:
PER PLAT-- MAINTAIN THE 20' DRAINAGE EASEMENT BETWEEN LOTS 2 & 3 MFE PER PLAT IS 116', NEED ELEVATION CONFIRMATION LETTER AT SLAB, ELEVATION LETTER REC'D AT 116.6'
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 1522
Total Area (Sqft) 2089
Stories 1
Septic# x-city
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Fema map number 12023C0293D
Review Notes
1/6/2020 Permit Issued Permit # created and approved.
Contractors
Name/ Business License Title Role
Adam R Papka
Adam's Construction Llc
County License & State License & Liability Insurance & Workers Comp Expired.
CBC1253409 Building Contractor Contractor
Donald Davis
High Springs Electric Inc.
EC0002306 Electrical Contractor Subcontractor
Clinton G Wilson
Wilson Heat & Air Inc
CAC057886 Class B A/c Subcontractor
Mark B Barrs
Barrs Plumbing,inc.
CFC057219 Plumbing Contractor Subcontractor
Caleb Laughlin
Precision Exteriors Llc
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CCC1327718 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 1/22/2020
Passed: Building - Monolithic Slab Matt Forsyth 1/27/2020
Passed: Engineering - Setbacks Matt Forsyth 1/27/2020
Passed: Electrical - Footer Steel & Grounding Matt Forsyth 1/27/2020
Passed: Building - Roof Decking Tommy Matthews 3/5/2020
Failed: Building - Ext Strapping/Wall Sheathing Too Many Shiners. Will Check Again At Framing Inspection. Ok To Cover. Tommy Matthews 3/5/2020
Failed: Building - Framing Inspection Provided But Will Not Pass Unless Deficient Items Are Taken Care Of, "strapping/wall Sheathing" Inspection Is Passed And Elevation Confirmation Letter Is Provided. framing Items: Required Is 3 Full Height Studs Each Side Of Garage Door. See "standard Header Schedule, Sheet S-2. need Anchor Bolts At Splice In Base Plate At Left Side Of Garage Door (outside Looking In). truss C2 (3) Not Clipped At Front Door. Tommy Matthews 3/10/2020
Failed: Building - Framing All Items Mentioned In Previous Framing Inspection Not Completed. Next Time If All Are Not Completed, There Will Be A $50 Reinspection Fee. Tommy Matthews 3/12/2020
Passed: Plumbing/Gas - 2nd Rough-In Tommy Matthews 3/20/2020
Passed: Building - Framing Tommy Matthews 3/20/2020
Failed: Electrical - 2nd Rough-In Smoke Detector Needs To Be At Least 3' From Ac Vent In Master Bedroom. Tommy Matthews 3/20/2020
Passed: Mechanical - Rough In Tommy Matthews 3/20/2020
Passed: Building - Ext Strapping/Wall Sheathing Tommy Matthews 3/20/2020
Cancelled: Building - Framing Tommy Matthews 3/26/2020
Passed: Building - Insulation Tommy Matthews 3/26/2020
Passed: Electrical - 2nd Rough-In Tommy Matthews 3/26/2020
Failed: Electrical - Permanent Power House Needs To Be Lockable. Need Conduit For Power Company Cable At Meter Can Tommy Matthews 7/1/2020
Passed: Electrical - Permanent Power Matt Forsyth 7/10/2020
Release to power company Matt Forsyth 7/10/2020
Failed: Building - Final Gfi Outlets Do Not Work In Kitchen, Baths And Laundry. need Blower Door Test Approval. need Final Termite Approval. Tommy Matthews 8/5/2020
Failed: Building - Final Need Blower Door Test Also Hot Water Heater Needs To Be Piped To The Outside From Drain Pan Matt Forsyth 9/9/2020
Passed: Building - Final Matt Forsyth 9/28/2020