Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 279 SW BUTTERCUP DR
LAKE CITY, FL 32024
Parcel #: 03023-543
Acres: 0.51
Owner: Sparks Construction & Design, Inc.
Subdivision: Rolling Meadows
Zoning: RSF-2
Flood Zone: X
District: 3
Application #: 44084
Permit #: 000038972
Related Permit:
Submitted:
Issued: Tuesday, December 3, 2019
Expires: Wednesday, December 23, 2020
Completed: Wednesday, December 23, 2020
Status: Completed
Septic Release? Yes
Notes:
PLANS REVIEWED BY PRIVATE PROVIDER, SEE ATTACHED FORMS. ALL BUILDING INSPECTIONS ALSO BY PRIVATE PROVIDER, ALL INSPECTION REPORTS REQUIRED FOR CERTIFICATE OF OCCUPANCY RELEASE AS PER F.S. 553.791 MINIMUM FLOOR ELEVATION - 108' PER PLAT, NEED ELEVATION CONFIRMATION LETTER AT SLAB, ELEVATION LETTER REC'D AT 110.58'.
Job Details
This is the construction of a Single Family Dwelling
Heated Area (Sqft) 2277
Total Area (Sqft) 3267
Stories 2
Building Height 20
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title SINGLE FAMILY DWELLING
Setbacks Front 25
Setback Side 1 10
Setback Side 2 10
Setbacks Rear 15
Septic# (00-0000) or (X00-000) 18-0877
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Finished floor requirement 108' PER PLAT
Fema map number 12023C0289D
In floodway N
Review Notes
11/26/2019 Point Review - Received
12/2/2019 Zoning Review - Completed/Sent for Final Review
12/3/2019 Final Review - Completed/Sent for Final Review
12/3/2019 Permit Issued Permit # created and approved.
5/15/2020 Point Review - Received
Contractors
Name/ Business License Title Role
Josh Sparks
Sparks Construction
CBC1252260 Building Contractor Contractor
Benjamin L Sparks
Line Electric Company, Llc
EC13009101 Cert. Electrical Subcontractor
Stephen M Brisbois
Epic Ac Service
Workers Comp Expired.
CAC1819412 Cert. A/c Class “b” Subcontractor
Cody Barrs
Barrs Plumbing,inc.
CFC1427145 Plumbing Contractor Subcontractor
Ralph W Laverdure
Rwl Roofing,llc.
CCC1328590 Roofing Contractor Subcontractor
Inspections
Inspection Notes Performed By Date
Building-Footer M.mcelroy Bn6543-report Attached Private Provider 12/6/2019
Plumbing/Gas-1st Underground Rough–In M.mcelory Bn6543-report Attached Private Provider 12/18/2019
Electrical -1st Underground Rough–In M.mcelory Bn6543-report Attached Private Provider 12/18/2019
Building-Slab M.mcelory Bn6543-report Attached Private Provider 12/26/2019
Electrical -Temporary Service M.mcelory Bn6543-report Attached Private Provider 1/13/2020
Release to power company Temp Power Insp Report Rec'd 1.10.20 Lh 1/13/2020
Building-Roof Decking M.mcelory Bn6543-report Attached Private Provider 2/10/2020
Building-Wall Sheathing M.mcelory Bn6543-report Attached Private Provider 2/10/2020
Building-Wall Sheathing Window Attachment, M.mcelory Bn6543-report Attached Private Provider 2/18/2020
Building-Roof Decking M.mcelory Bn6543-report Attached Private Provider 2/18/2020
Building-Framing M.mcelory Bn6543-report Attached, Partial Private Provider 2/25/2020
Electrical -2nd Rough-In M.mcelory Bn6543-report Attached, Partial Private Provider 2/25/2020
Plumbing/Gas-2nd Rough-In M.mcelory Bn6543-report Attached, Partial Private Provider 2/25/2020
Mechanical-Rough In M.mcelory Bn6543-report Attached, Partial Private Provider 2/25/2020
Building-Framing M.mcelory Bn6543-report Attached Private Provider 3/3/2020
Electrical -2nd Rough-In M.mcelory Bn6543-report Attached Private Provider 3/3/2020
Mechanical-Rough In M.mcelory Bn6543-report Attached Private Provider 3/3/2020
Plumbing/Gas-2nd Rough-In M.mcelory Bn6543-report Attached Private Provider 3/3/2020
Building-Insulation M.mcelory Bn6543-report Attached Private Provider 3/4/2020
Electrical -Permanent Power M.mcelory Bn6543-report Attached, Need Elevation Letter Before Power Can Be Released. Private Provider 5/8/2020
Septic Release Inspection Elevation Letter Rec'd Health Dept 5/12/2020
Passed: Release to power company Culvert Permit #39984, Bdt Rec'd 4.5 Laurie Hodson 5/28/2020
Building-Final Failed- Need New Sash With Safety Glazing. - Need Termite Final Certificate Private Provider 11/16/2020
Certificate-Release Certificate Rec'd Final Inspection Report From Private Provider.. all Corrections Satisfied! Troy Crews 12/23/2020
Documents
File Name Date File Size
Application Packet 2019-12-05 11.39.00 Am.pdf 2023.12.26 70.13kB
Original Permit 20191203.pdf 2023.12.26 44.36kB
Blueprints 2019-12-04 07.38.35.956.pdf 2023.12.26 6.71MB
Uesdocs- 1737256-v1-rpt_bid_rolling_meadows_lot_43_sparks_construction_ 2020-01-08 08.14.26.532.pdf 2023.12.26 89.39kB
Final Termite Report Aug 26 2020 - 12-37 Pm 38972 2020-11-24 11.58.11.287.pdf 2023.12.26 317.06kB
44084 Res Checklist And Energy Docs 2019-12-04 07.45.37.53.pdf 2023.12.26 1.20MB
38972_sparks_construction_rolling_meadows_lot_43_electrical_plumbing_rough 2019-12-18 17.10.39.685.pdf 2023.12.26 93.93kB
Sparksbdt 2020 2020-10-08 10.27.23.743.pdf 2023.12.26 750.58kB
Trades Inspection Reports 2020-07-01 17.42.49.781.pdf 2023.12.26 444.31kB
44084 Truss Engineering 2019-12-04 07.45.16.271.pdf 2023.12.26 4.50MB
Footer Insp Rpt 38972 2019-12-11 16.08.56.178.pdf 2023.12.26 72.38kB
App 44084 Pp Plan Review Affidavit And Inspector Lic 2019-12-03 11.59.03.691.pdf 2023.12.26 97.11kB
44084 Application Submittal 2019-12-04 07.45.27.755.pdf 2023.12.26 912.89kB
Availability Letter - 279 Sw Buttercup Dr. 2019-12-05 12.38.04.593.pdf 2023.12.26 444.66kB
Window And Roof Inspection Report 2020-07-01 17.45.24.837.pdf 2023.12.26 573.91kB
Termite Treatment 38972 2020-11-24 11.58.04.178.pdf 2023.12.26 555.66kB
38972 Not Complete Final Inspection Report 2020-11-19 15.38.07.127.pdf 2023.12.26 95.28kB
Sheathing Inspection Report 2020-07-01 17.46.12.418.pdf 2023.12.26 542.05kB
Power Release-release To Power Company 20200528.pdf 2023.12.26 38.56kB
Pp Temp Power Insp Report 2020-01-13 11.58.53.705.pdf 2023.12.26 539.02kB
Complete Final Inspection Report.pdf 2023.12.26 540.05kB
Pp Temp Power Insp Report 2020-01-13 11.59.02.909.pdf 2023.12.26 539.02kB
Plans_44084 2019-12-23 11.00.31.947.pdf 2023.12.26 6.71MB
Surveyor Elevation Letter 03023-543 2020-05-28 15.03.19.51.pdf 2023.12.26 419.98kB
App 44084 Pp Inspector Lic And Coi 2019-12-03 11.59.25.05.pdf 2023.12.26 247.11kB
App 44084 Pp Use Form 2019-12-03 11.59.14.973.pdf 2023.12.26 114.14kB
Certificate Of Occupancy 20201223.pdf 2023.12.26 50.80kB
Inspection Reports Sheathing Window 2nd Roughs Framing Insulation Perm Power.pdf 2023.12.26 2.22MB