Permit Details

Permit Search

Permit

New Residential Construction

1044 NW BLACKBERRY CR
LAKE CITY, FL 32055

Permit #
000038905
Application #
43866
Status Completed
  1. Submitted Oct 22, 2019
  2. Issued Nov 18, 2019
  3. Expires Oct 25, 2020
  4. Completed Apr 28, 2020

Property

Parcel #
02168-121
Owner
Maximum Real Estate, Llc
Acres
2.54
Subdivision
Blackberry Farms
Zoning
PRRD
Flood zone
X
District
3

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
1' ABOVE ROAD
Fema map number
12023C0280D
In floodway
N
This is the construction of a
Single Family Dwelling
Setbacks Front
90
Setback Side 1
85.3
Setback Side 2
85.3
Setbacks Rear
316.2
Stories
1
Heated Area (Sqft)
2245
Total Area (Sqft)
3209
Building Height
17
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
SINGLE FAMILY DWELLING
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
19-0799

Status & Review History

  1. Zoning Review - Processing
  2. Zoning Review - Completed/Sent for Final Review
  3. Permit Issued

Contractors

  • Mark Bauer

    Gibraltar Contracting Llc

    License
    CBC1259633
    Title
    Cert Building
    Role
    Contractor

    County License & State License Expired.

  • Ryan C Beville

    Rbi Electrical Contracting Llc

    License
    EC13004236
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Clinton G Wilson

    Wilson Heat & Air Inc

    License
    CAC057886
    Title
    Class B A/c
    Role
    Subcontractor
  • James Butler Jr

    Butler Plumbing Of Gainesville Inc

    License
    CFC057960
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Jeffrey Bokor

    Dwc Contracting Llc

    License
    CCC1329756
    Title
    Roofing Contractor
    Role
    Subcontractor

    Liability Insurance Expired.

Inspections

  1. Nov 21, 2019

    Passed: Building - Footer

    Inspected by Tommy Matthews

  2. Nov 21, 2019

    Passed: Engineering - Setbacks

    Inspected by Tommy Matthews

  3. Nov 21, 2019

    Passed: Electrical - Temporary Service

    Inspected by Tommy Matthews

  4. Nov 21, 2019

    Release to power company

    Inspected by Tommy Matthews

  5. Dec 3, 2019

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Troy Crews

  6. Dec 5, 2019

    Passed: Building - Slab

    Inspected by Matt Forsyth

  7. Dec 31, 2019

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  8. Dec 31, 2019

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  9. Jan 14, 2020

    Passed: Building - Framing

    Inspected by Tommy Matthews

  10. Jan 14, 2020

    Passed: Electrical - 2nd Rough-In

    Inspected by Tommy Matthews

  11. Jan 14, 2020

    Passed: Mechanical - Above Ceiling

    Inspected by Tommy Matthews

  12. Jan 14, 2020

    Passed: Plumbing/Gas - 2nd Rough-In

    Inspected by Tommy Matthews

  13. Jan 16, 2020

    Passed: Building - Insulation

    Inspected by Tommy Matthews

  14. Mar 2, 2020

    Septic Release Inspection

    Inspected by Health Dept

  15. Mar 12, 2020

    Passed: Electrical - Permanent Power

    Need Drive Final

    Inspected by Troy Crews

  16. Mar 13, 2020

    Release to power company

    Inspected by Mg

  17. Apr 28, 2020

    Passed: Building - Final

    Inspected by Tommy Matthews