Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 237 SW HILL CREEK DR
LAKE CITY, FL 32025
Parcel #: 09116-130
Acres: 5.00
Owner: Donnie & Sheila Blackwell
Subdivision: Hills At Rose Creek
Zoning: A-3
Flood Zone: X
District: 4
Application #: 42492
Permit #: 000038531
Related Permit:
Submitted: Tuesday, August 27, 2019
Issued: Tuesday, August 27, 2019
Expires: Thursday, April 30, 2020
Completed: Thursday, April 30, 2020
Status: Completed
Septic Release? Yes
Notes:
NOC ON FILE, FLOOR 1' ABOVE ROAD
Job Details
This is the construction of a SFD/UTILITY
Heated Area (Sqft) 2598.00
Total Area (Sqft) 3363.00
Stories 1
Setbacks Front 30.00
Setback Side 1 25.00
Setback Side 2 25.00
Setbacks Rear 25.00
Septic# (00-0000) or (X00-000) 19-0609
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Fema map number 12023C0384D
Review Notes
Contractors
Name/ Business License Title Role
Max Bass

County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
R282811195
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Need Compaction Test On Fill Areas Troy Crews 9/18/2019
Passed: Engineering - Setbacks Troy Crews 9/18/2019
Passed: Electrical - Temporary Service Troy Crews 9/18/2019
Release to power company Troy Crews 9/18/2019
Passed: Plumbing/Gas - 1st Underground Rough–In Matt Forsyth 10/23/2019
Passed: Building - Slab Troy Crews 10/29/2019
Passed: Building - Slab Troy Crews 11/5/2019
Passed: Building - Ext Strapping/Wall Sheathing Matt Forsyth 12/13/2019
Failed: Building - Framing Porch Posts Do Not Have Required Lsta24 Installed. porch Ceiling Must Be Sheathed W/min 3/8” Osb. 2-2x4 Required Under D2gir Truss. new Opening For Door Not Shown For Right Rear Bedroom. Must Have Engineer Account For This In Design. See S-3. window Below Truss D7gir Requires 2 King Studs. truss F3gir Requires 3-2x4 Centered Under Each End. truss C1gir Needs 2-2x4 Centered Under Each End Of Truss. anchor Bolts Required Within 6” Each Side Of Plate Joint. truss C4, C5, C6, And C7 Missing Engineering Brace. Tommy Matthews 2/5/2020
Passed: Electrical - 2nd Rough-In Tommy Matthews 2/5/2020
Passed: Mechanical - Above Ceiling Tommy Matthews 2/5/2020
Failed: Plumbing/Gas - 2nd Rough-In Seal Hole Under Fiberglass Tub On Right Side Of House. Tommy Matthews 2/5/2020
Failed: Building - Roof Decking Remove Shiner On Left Rear Hip. Renail At That Location. Tommy Matthews 2/5/2020
Passed: Building - Framing Install 3/8” Osb On Ceiling Of Back Porch. Tommy Matthews 2/7/2020
Failed: Plumbing/Gas - 2nd Rough-In See Picture Attached Tommy Matthews 2/7/2020
Passed: Plumbing/Gas - 2nd Rough-In Tommy Matthews 2/10/2020
Passed: Building - Insulation Troy Crews 2/18/2020
Septic Release Inspection Health Dept 4/13/2020
Passed: Electrical - Permanent Power Troy Crews 4/13/2020
Release to power company Troy Crews 4/13/2020
Passed: Building - Final Tommy Matthews 4/30/2020