Permit Information

New Residential Construction Permit

Address 449 SW MADISON CT
LAKE CITY, FL 32024
Parcel #: 02791-106
Acres:5.01
Owner:Sharon Baldauf-madero & Mark Madero
Subdivision:Westwind Estates
Zoning:A-3
Flood Zone:X
District:2
Application #:40541
Permit #: 000037899
Related Permit:
Submitted:Monday, March 25, 2019
Issued:Monday, March 25, 2019
Expires:Monday, November 16, 2020
Completed:Monday, November 16, 2020
Status: Completed
Septic Release? Yes

Notes

ONE FOOT ABOVE ROAD. NOC ON FILE, ENGINEER LETTER REC'D WITH REQUIREMENTS- STRUCTURE SHALL BE 12 INCHES ABOVE THE EXISTING GROUND AT ANY POINT ALONG THE PERIMETER AND IN NO CASE SHALL THE FINISHED FLOOR ELEVATION BE LESS THAN 111.00', NEED ELEVATION LETTER FROM SURVEYOR AT 111.00 OR ABOVE. SURVEYOR ELEVATION LETTER REC'D - FINISHED FLOOR ELEVATION IS 114.7'.

Job Details

Finished floor requirement
Fema map number 12023C0290D
This is the construction of a SFD/UTILITY
Setbacks Front 30.00
Setback Side 1 25.00
Setback Side 2 25.00
Setbacks Rear 25.00
Heated Area (Sqft) 2532.00
Total Area (Sqft) 3780.00
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000) 19-0170

Review Notes

Contractors

Name / Business License Title Role
Sharon B-madero & Mark Madero

OWNER

Inspections

Inspection Notes Performed By Date
Passed: Building - Footer Troy Crews 4/2/2019
Passed: Engineering - Setbacks Troy Crews 4/2/2019
Passed: Plumbing/Gas - Underground Rough-In Troy Crews 5/10/2019
Passed: Building - Slab Troy Crews 5/14/2019
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 10/8/2019
Passed: Building - Framing Troy Crews 10/30/2019
Passed: Building - Roof Decking Troy Crews 10/30/2019
Passed: Electrical - 2nd Rough-In Troy Crews 2/11/2020
Passed: Mechanical - Rough In Troy Crews 4/30/2020
Passed: Plumbing/Gas - 2nd Rough-In Troy Crews 4/30/2020
Passed: Building - Insulation Troy Crews 6/10/2020
Septic Release Inspection Health Dept 9/9/2020
Passed: Electrical - Permanent Power Troy Crews 9/22/2020
Release to power company Troy Crews 9/22/2020
Passed: Building - Final Troy Crews 11/16/2020

Contact Us

Building Department

Office Hours

Monday-Friday
8:00 A.M. - 4:30 P.M.

Contact Information

Phone: 386-758-1008
Fax: 386-758-2160

Email: bldginfo@columbiacountyfla.com

Location

135 NE Hernando Ave.
Lake City, FL 32055 (opens in new window)

Mailing Address

P.O. Box 1529
Lake City, FL 32056-1529

Public Records

Public records policy and fees

Board of County Commissioners
Tel. (386) 758-1326
Fax: (386) 758-2182
Email: publicrecords@columbiacountyfla.com

Mailing Address:
P.O. Box 1529
Lake City, FL 32056-1529

Citizen Feedback

Let us know how we're doing

ADA Accessibility

Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the Columbia County ADA Coordinator at (386) 758-3344. You may also email that office at hr@columbiacountyfla.com and provide a brief description of the inaccessible feature.

Columbia County strives to provide reasonable accommodations to help people with disabilities have an equal opportunity to participate in our public meetings. Please notify our ADA Coordinator at least 48 hours prior to the public meeting by calling (386) 758-3344.