Permit Details

Permit Search

Permit

New Residential Construction

1022 SW MARYNIK DR
HIGH SPRINGS, FL 32643

Permit #
000037485
Application #
39918
Status Completed
  1. Submitted Nov 28, 2018
  2. Issued Nov 28, 2018
  3. Expires Nov 5, 2019
  4. Completed May 10, 2019

Property

Parcel #
10006-228
Owner
Samantha & Fredrick Findley Iii
Acres
7.10
Subdivision
River Rise
Zoning
AG-3
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0513C
This is the construction of a
SFD, UTILITY
Setbacks Front
30.00
Setback Side 1
25.00
Setback Side 2
25.00
Setbacks Rear
25.00
Stories
1
Heated Area (Sqft)
2048.00
Total Area (Sqft)
2356.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
18-0926

Status & Review History

No status updates yet.

Contractors

  • Adam Papka

    License
    CBC1253409
    Title
    —
    Role
    —

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Nov 29, 2018

    Failed: Electrical - Temporary Service

    Pole Not Set

    Inspected by Troy Crews

  2. Nov 29, 2018

    Passed: Plumbing/Gas - Underground Rough-In

    Inspected by Troy Crews

  3. Dec 6, 2018

    Release to power company

    Inspected by Troy Crews

  4. Dec 10, 2018

    Passed: Electrical - Temporary Service

    Inspected by Troy Crews

  5. Dec 10, 2018

    Passed: Building - Slab

    Inspected by Troy Crews

  6. Dec 31, 2018

    Passed: Building - Roof Decking

    Inspected by Troy Crews

  7. Dec 31, 2018

    Passed: Building - Ext Strapping/Wall Sheathing

    Inspected by Troy Crews

  8. Jan 14, 2019

    Passed: Building - Framing

    Inspected by Troy Crews

  9. Jan 14, 2019

    Passed: Electrical - Rough In

    Inspected by Troy Crews

  10. Jan 14, 2019

    Passed: Mechanical - Rough In

    Inspected by Troy Crews

  11. Jan 14, 2019

    Passed: Plumbing/Gas - Rough In

    Inspected by Troy Crews

  12. Jan 15, 2019

    Passed: Building - Insulation

    Inspected by Troy Crews

  13. Mar 15, 2019

    Failed: Electrical - Permanent Power

    House Needs To Be Lockable.

    Inspected by Tommy Matthews

  14. Mar 21, 2019

    Passed: Electrical - Permanent Power

    Door Locks Installed Needs Final Septic And Driveway

    Inspected by Troy Crews

  15. Apr 16, 2019

    Septic Release Inspection

    Inspected by Health Dept

  16. Apr 18, 2019

    Release to power company

    Eh Rec'd

    Inspected by Troy Crews

  17. May 9, 2019

    Passed: Building - Final

    Release Pending Blower Door. Rec'd 5/10/19

    Inspected by Troy Crews