Permit Details

Permit Search

Permit

New Residential Construction

182 NW NASH RD
LAKE CITY, FL 32055

Permit #
000037171
Application #
39456
Status Completed
  1. Submitted Sep 4, 2018
  2. Issued Sep 4, 2018
  3. Expires Dec 3, 2019
  4. Completed Jun 10, 2019

Property

Parcel #
02142-002
Owner
Jesse Boone
Acres
5.01
Subdivision
—
Zoning
AG-3
Flood zone
X
District
—

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
This is the construction of a
SFD, UTILITY
Setbacks Front
30.00
Setback Side 1
25.00
Setback Side 2
25.00
Setbacks Rear
25.00
Stories
2
Heated Area (Sqft)
3760.00
Total Area (Sqft)
4460.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
18-0690

Status & Review History

No status updates yet.

Contractors

  • David Simque

    License
    CGC1516165
    Title
    —
    Role
    —

    County License & State License & Liability Insurance Expired.

Inspections

  1. Sep 5, 2018

    Passed: Building - Monolithic Slab

    Inspected by Troy Crews

  2. Sep 5, 2018

    Passed: Engineering - Setbacks

    Inspected by Troy Crews

  3. Sep 5, 2018

    Passed: Plumbing/Gas - Underground Rough-In

    Waste Only

    Inspected by Troy Crews

  4. Nov 16, 2018

    Passed: Building - Framing

    Inspected by Troy Crews

  5. Nov 16, 2018

    Passed: Electrical - Rough In

    Inspected by Troy Crews

  6. Nov 16, 2018

    Passed: Mechanical - Rough In

    Need Bath Fan Ducts Upstairs

    Inspected by Troy Crews

  7. Nov 16, 2018

    Passed: Plumbing/Gas - Rough In

    Inspected by Troy Crews

  8. Feb 20, 2019

    Passed: Electrical - Permanent Power

    Need Health Final

    Inspected by Troy Crews

  9. Feb 22, 2019

    Release to power company

    Inspected by Laurie Hodson

  10. Feb 22, 2019

    Septic Release Inspection

    Inspected by Health Dept

  11. Jun 6, 2019

    Passed: Building - Final

    Need Blower Door Test blower Door Test Recieved

    Inspected by Troy Crews