Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 251 SW BREEZY DR
LAKE CITY, FL 32025
Parcel #: 08944-012
Acres: 5.11
Owner: Dustin F. Mcmanus
Subdivision: Hillcrest Unrec
Zoning: AG-3
Flood Zone: X
District: 4
Application #: 39416
Permit #: 000037147
Related Permit:
Submitted: Monday, August 27, 2018
Issued: Monday, August 27, 2018
Expires: Thursday, May 16, 2019
Completed: Thursday, May 16, 2019
Status: Completed
Septic Release? Yes
Notes:
FLOOR ONE FOOT ABOVE THE ROAD, NOC ON FILE
Job Details
This is the construction of a SFD, UTILITY
Heated Area (Sqft) 2184.00
Total Area (Sqft) 3600.00
Stories 1
Setbacks Front 30.00
Setback Side 1 25.00
Setback Side 2 25.00
Setbacks Rear 25.00
Septic# (00-0000) or (X00-000) 18-0693
Building Code Edition Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Fema map number 12023C0401C
Review Notes
Contractors
Name/ Business License Title Role
Jason Elixson

County License & State License & Liability Insurance & Workers Comp Expired.
CBC1250331
Inspections
Inspection Notes Performed By Date
Passed: Electrical - Temporary Service Troy Crews 9/6/2018
Release to power company Troy Crews 9/6/2018
Passed: Building - Footer Troy Crews 9/12/2018
Passed: Engineering - Setbacks Reminder 1ft, Above Road Troy Crews 9/12/2018
Passed: Plumbing/Gas - Underground Rough-In Troy Crews 10/2/2018
Passed: Building - Slab Troy Crews 10/3/2018
Passed: Building - Ext Strapping/Wall Sheathing Troy Crews 11/8/2018
Failed: Building - Framing Check Bracing A-02 And A-03 Truss, Anchor Bolts At Green Paint Spots, Add Nails Rear Porch Header Both Sides Troy Crews 12/20/2018
Passed: Electrical - Rough In Troy Crews 12/20/2018
Failed: Mechanical - Rough In Attatch Bath Fan Duct East Side Bath Troy Crews 12/20/2018
Passed: Plumbing/Gas - Rough In Troy Crews 12/20/2018
Passed: Building - Framing Troy Crews 12/21/2018
Passed: Mechanical - Rough In Troy Crews 12/21/2018
Passed: Building - Insulation Troy Crews 1/11/2019
Passed: Electrical - Permanent Power Need Health Release Troy Crews 4/17/2019
Release to power company Lh 4/18/2019
Septic Release Inspection Health Dept 4/18/2019
Passed: Building - Final Troy Crews 5/15/2019
Documents
File Name Date File Size
Permit-000037147.pdf 2023.12.26 39.69kB