Permit
298 SW PROSPERITY PLLAKE CITY, FL 32024
No status updates yet.
Carson Mccall
County License & State License Expired.
Release to power company
Inspected by Troy Crews
Passed: Electrical - Temporary Service
Passed: Electrical - Underground Rough-In
Main Conduits From Electric Room To Transformer
Passed: Plumbing/Gas - Underground Rough-In
Approved As Per Notes
Passed: Plumbing/Gas - Sanitary
Approved Per Notes
Passed: Plumbing/Gas - Rain Leader
Passed: Building - Footer
Approved As Requested
Passed: Engineering - Setbacks
Cancelled: Building - Slab
Passed: Building - Masonry Wall Reinforcing
Approved As Requested Sremwall
Approved As Requested Waste Lines
Passed: Electrical - Footer Steel & Grounding
Rescheduled 4/3/2018:Building - Masonry Wall Reinforcing
Rescheduled 4/3/2018:Plumbing/Gas - Rough In
Rescheduled 4/4/2018:Plumbing/Gas - Sanitary
Passed: Plumbing/Gas - Rough In
Passed: Building - Slab
Cancelled: Plumbing/Gas - Underground Rough-In
Cancelled: Plumbing/Gas - Sanitary
Passed: Plumbing/Gas - Water Pipe
Approved As Requested Domestic Water
Passed: Building - Lintel/Tie Beam
Passed: Building - Roof Decking
Approved Zone 5
Passed: Building - Vertical Cells/Columns
Passed: Building - Framing
Passed: Fire - Underground Main - Visual
Inspected by Josh Wehinger
Passed: Plumbing/Gas - Interceptor
Back To Back Grease Tanks Approved As Requested
Passed: Building - Rated Assembly Fastening
Hallway And Partial Bathrooms Zone 1 And Partial Hallway Zone 2
Rescheduled 8/6/2018:Plumbing/Gas - Water Pipe
Approved As Requested 100 Psi
Passed: Fire - Operational Test - Chemical/Gaseous Agent
Passed: Electrical - Above Ceiling
Rough In Tower Area Approved As Requested
Passed: Mechanical - Above Ceiling
Passed: Building - Insulation
Approved As Requested Tower Area
Passed: Fire - Aboveground Sprinkler - Visual (On Site)
Passed: Building - Above Ceiling
Passed: Electrical - Rough In
Passed: Mechanical - Rough In
Approved As Requested Zone 1
Approved As Requested 100 P.si.
Nw Section
Hard Ceiling Areas
Failed: Plumbing/Gas - Water Pipe
Leak 1st Hallway To Left From North Entrance By Bulkhead
4 Primary’s 2 Secondary Full
90 P.si.
Patient Rooms And Center Core
Passed: Mechanical - Framing/Fire Damper
Patient Rooms Hallway Not Complete
Rescheduled 11/14/2018:Plumbing/Gas - Water Pipe
Rescheduled 11/14/2018:Plumbing/Gas - Rough In
Kitchen Area Hard Ceiling
Passed: Fire - Kitchen Hood – Fire Suppression Test
Passed: Electrical - Permanent Power
Temp Permanent City Sewer
Approved As Requested R-38
Inspected by Tad Cervantes
Passed: Fire - Aboveground Hydro - Sprinkler
Inspection Was Preformed On Friday, 1-18-19.
Passed: Building - Lath/Stucco
Approved As Requested, Suggestion Let City Gas Dept. Look At It Also
Failed: Electrical - Above Ceiling
Few Boxes Still Open
Cancelled: Mechanical - Above Ceiling
Cancelled: Mechanical - Rough In
Cancelled: Mechanical - Pipe Pressure Test
Failed: Fire - Fire Final
Inspection Was Not Performed On This Day. A Walk-thru With Supervisor Was Performed On Life Safety Issues That He Had. Issues Are Being Resolved And A Final Inspection Will Follow Shortly. Tjc
Passed: Fire - Fire Final
Passed: Building - Final
Rooftop Areas A.c. Units And Service Plugs
Release Of C.o. Pending Site Final, And Final Walkthrough
Passed: Engineering - Zoning Final
Meets Revisions Inspected On 5/3/19
Inspected by Brandon Stubbs