Permit Details

Permit Search

Permit

New Residential Construction

341 SW RIDGE ST LAKE CITY FL 32024

Permit #
000035536
Application #
31858
Status Completed
  1. Submitted Jul 11, 2017
  2. Issued Jul 11, 2017
  3. Expires Sep 30, 2018
  4. Completed Apr 4, 2018

Property

Parcel #
03171-011
Owner
David & Emily Martin
Acres
3.94
Subdivision
Oak Ridge Estates
Zoning
AG-3
Flood zone
X
District
5

Permit

Status
Completed
Septic release
Released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0381D
This is the construction of a
SFD, UTILITY
Setbacks Front
30.00
Setback Side 1
25.00
Setback Side 2
25.00
Setbacks Rear
25.00
Stories
1
Heated Area (Sqft)
2714.00
Total Area (Sqft)
4183.00
Building Code Edition
Florida Building Code 2017 6th Edition & 2014 National Electrical Code
Septic# (00-0000) or (X00-000)
17-0403-N

Status & Review History

No status updates yet.

Contractors

  • Blake Lunde

    Blake Construction Company Of North Florida Inc

    License
    CBC1253408
    Title
    Building Contractor
    Role
    —

    County License & State License & Liability Insurance & Workers Comp Expired.

Inspections

  1. Jul 26, 2017

    Setback Inspection

    Inspected by Randy Jones

  2. Jul 26, 2017

    Setback Inspection

    Inspected by Randy Jones

  3. Jul 28, 2017

    Foundation Inspection

    Inspected by Randy Jones

  4. Jul 28, 2017

    Temporary Power Inspection

    Inspected by Troy Crews

  5. Jul 28, 2017

    Foundation Inspection

    Inspected by Randy Jones

  6. Aug 8, 2017

    Perimeter Beam/Column Inspection

    Inspected by Troy Crews

  7. Aug 16, 2017

    Underslab Rough Plumbing Inspection

    Inspected by Troy Crews

  8. Aug 17, 2017

    Slab Inspection

    Inspected by Tommy Matthews

  9. Oct 3, 2017

    Sheathing and Nailing Inspection

    Inspected by Troy Crews

  10. Oct 27, 2017

    Framing Inspection

    Inspected by Troy Crews

  11. Oct 27, 2017

    Rough-In Plumbing Inspection

    Inspected by Troy Crews

  12. Oct 27, 2017

    Electrical Rough-In Inspection

    Inspected by Troy Crews

  13. Oct 27, 2017

    Heat and Air Duct Inspection

    Inspected by Troy Crews

  14. Nov 14, 2017

    Insulation Inspection

    Inspected by Troy Crews

  15. Feb 22, 2018

    Septic Release Inspection

    Inspected by Health Dept

  16. Feb 22, 2018

    Failed: Electrical - Permanent Power

    Need Conduit Installed To Meter Can

    Inspected by Troy Crews

  17. Feb 23, 2018

    Passed: Electrical - Permanent Power

    Inspected by Troy Crews

  18. Mar 5, 2018

    Release to power company

    Inspected by Laurie Hodson

  19. Apr 3, 2018

    Passed: Building - Final

    Inspected by Troy Crews

  20. Apr 4, 2018

    CERTIFICATE OF OCCUPANCY/COMPLETION DATE

  21. Apr 4, 2018

    Final Inspection

    Inspected by Troy Crews

  22. Requested

    Framing

    Awaiting inspection

  23. Requested

    Above slab Rough-in

    Awaiting inspection

  24. Requested

    Electrical Rough-in

    Awaiting inspection

  25. Requested

    Heat & AC -

    Awaiting inspection