Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 126 SW JULBUG GLEN
FT. WHITE, FL 32038
Parcel #: 00821-000
Acres: 0.00
Owner: Robert Kelley
Subdivision: Three Rivers Estates
Zoning: ESA-2
Flood Zone: AE
District: 2
Application #: 20759
Permit #: 000030534
Related Permit:
Submitted: Thursday, October 18, 2012
Issued: Thursday, October 18, 2012
Expires: Friday, March 22, 2013
Completed: Friday, March 22, 2013
Status: Completed
Septic Release? No
Notes:
FLOODWAY, ELEVATION CERTIFICATE INCLUDING EQUIPMENT FINISHED. NOC CONSTRUCTION. MFE @ 33.39'. INSPECTOR NEED TO CONFIRM 30' SETBACK ELE. CERT REC'D.-OK PER BK DENSITY TEST REC'D
Job Details
This is the construction of a SFD/UTILITY
Heated Area (Sqft) 836.00
Total Area (Sqft) 1848.00
Stories 1
Setbacks Front 30.00
Setback Side 1 25.00
Setback Side 2 25.00
Setbacks Rear 25.00
Building Code Edition Florida Building Code 2014 5th Edition & 2011 National Electrical Code
Fema map number 12023C0466C
Review Notes
Contractors
Name/ Business License Title Role
Tracy Winters
Winters Construction Group,llc.
County License & State License & Liability Insurance & Workers Comp Expired.
CBC059798 Building Contractor
Inspections
Inspection Notes Performed By Date
Monolithic Slab Inspection Troy Crews 11/16/2012
Setback Inspection Troy Crews 11/16/2012
Perimeter Beam/Column Inspection Troy Crews 11/29/2012
Framing Inspection Troy Crews 1/7/2013
Rough-In Plumbing Inspection Troy Crews 1/7/2013
Electrical Rough-In Inspection Troy Crews 1/7/2013
Heat and Air Duct Inspection Troy Crews 1/7/2013
Insulation Inspection Tommy Matthews 1/11/2013
Permanent Power Inspection Tommy Matthews 2/26/2013
Final Inspection Troy Crews 3/22/2013
CERTIFICATE OF OCCUPANCY/COMPLETION DATE 3/25/2013
Documents
File Name Date File Size
Ec 00821-000 30534 2020-08-04 11.26.45.114.pdf 2023.12.21 1.54MB
Elevation Report-30534.pdf 2023.12.21 303.71kB
Permit-30534.pdf 2023.12.21 97.87kB
Certificate Of Occupancy.pdf 2023.12.21 141.08kB
Documentation 20200730 124047.pdf 2023.12.21 23.85MB
Plans 2020-07-30 16.44.38.149.pdf 2023.12.21 7.36MB