Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit

Address 181 SW BRIARBROOK PLACE
LAKE CITY, FL 32024
Parcel #: 03121-055
Acres: 0.50
Owner: Norton Home Imp. Co., Inc.
Subdivision: Piccadilly Park South
Zoning: RSF-2
Flood Zone: X
District: 5
Application #: 24951
Permit #: 000026025
Related Permit:
Submitted: Monday, July 16, 2007
Issued: Monday, July 16, 2007
Expires: Friday, November 16, 2007
Completed: Friday, November 16, 2007
Status: Completed
Septic Release? No
Notes:
ONE FOOT ABOVE THE ROAD, NOC ON FILE
Job Details
Finished floor requirement
Fema map number 12023C0381D
This is the construction of a SFD,UTILITY
Setbacks Front 25.00
Setback Side 1 10.00
Setback Side 2 10.00
Setbacks Rear 15.00
Stories 1
Heated Area (Sqft) 1647.00
Total Area (Sqft) 2440.00
Building Code Edition Florida Building Code 2014 5th Edition & 2011 National Electrical Code
Review Notes
Contractors
Name/ Business License Title Role
James H. Norton

County License & State License & Liability Insurance & Workers Comp Expired.
RB0031780
Inspections
Inspection Notes Performed By Date
Temporary Power Inspection Harry Dicks 7/24/2007
Foundation Inspection Harry Dicks 7/24/2007
Setback Inspection Harry Dicks 7/24/2007
Underslab Rough Plumbing Inspection Randy Jones 7/31/2007
Underslab Rough Plumbing Inspection Randy Jones 7/31/2007
Slab Inspection Randy Jones 8/6/2007
Slab Inspection Randy Jones 8/6/2007
Sheeting and Nailing Inspection Randy Jones 9/10/2007
Sheathing and Nailing Inspection Randy Jones 9/10/2007
Sheathing and Nailing Inspection Randy Jones 9/10/2007
Framing Inspection John Kerce 9/18/2007
Rough-In Plumbing Inspection John Kerce 9/18/2007
Electrical Rough-In Inspection John Kerce 9/18/2007
Heat and Air Duct Inspection John Kerce 9/18/2007
Permanent Power Inspection John Kerce 11/8/2007
Permanent Power Inspection Jdk 11/8/2007
Final Inspection Randy Jones 11/16/2007
CERTIFICATE OF OCCUPANCY/COMPLETION DATE 11/16/2007
Final Inspection Randy Jones 11/16/2007
Documents
File Name Date File Size
Plans 2020-04-01 17.01.45.759.pdf 2025.07.04 5.93MB
Certificate Of Occupancy.pdf 2025.06.22 141.64kB
Application Packet 2020-04-02 11.49.16 Am.pdf 2023.12.21 2.58MB