Permit Details

Permit Search

Permit

New Residential Construction

205 SE MAUBURY PLACE LAKE CITY FL 32025

Permit #
000023444
Application #
27655
Status Completed
  1. Submitted Aug 2, 2005
  2. Issued Aug 2, 2005
  3. Expires Jan 29, 2006
  4. Completed Aug 3, 2006

Property

Parcel #
08366-003
Owner
Aleene & Kurt Havird
Acres
1.00
Subdivision
Elm Acres
Zoning
RSF-2
Flood zone
X
District
4

Permit

Status
Completed
Septic release
Not yet released
Related permit
—

Job Details

Finished floor requirement
Fema map number
12023C0313D
This is the construction of a
SFD,UTILITY
Setbacks Front
25.00
Setback Side 1
10.00
Setback Side 2
10.00
Setbacks Rear
15.00
Stories
2
Heated Area (Sqft)
2313.00
Total Area (Sqft)
3288.00
Building Code Edition
Florida Building Code 2014 5th Edition & 2011 National Electrical Code

Status & Review History

No status updates yet.

Contractors

  • Glenwood King

    Glenwood King Construction, Inc.

    License
    CBC059726
    Title
    Building Contractor
    Role
    —

    County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.

Inspections

  1. Aug 11, 2005

    Temporary Power Inspection

    Inspected by Randy Jones

  2. Aug 11, 2005

    Foundation Inspection

    Inspected by Randy Jones

  3. Aug 11, 2005

    Setback Inspection

    Inspected by Randy Jones

  4. Aug 11, 2005

    Temporary Power Inspection

    Inspected by Randy Jones

  5. Aug 30, 2005

    Underslab Rough Plumbing Inspection

    Inspected by Randy Jones

  6. Aug 30, 2005

    Underslab Rough Plumbing Inspection

    Inspected by Randy Jones

  7. Sep 6, 2005

    Slab Inspection

    Inspected by Harry Dicks

  8. Sep 28, 2005

    Sheeting and Nailing Inspection

    Inspected by Randy Jones

  9. Sep 28, 2005

    Sheathing and Nailing Inspection

    Inspected by Randy Jones

  10. Sep 28, 2005

    Sheathing and Nailing Inspection

    Inspected by Randy Jones

  11. Oct 14, 2005

    Framing Inspection

    Inspected by Randy Jones

  12. Oct 14, 2005

    Rough-In Plumbing Inspection

    Inspected by Randy Jones

  13. Oct 14, 2005

    Electrical Rough-In Inspection

    Inspected by Randy Jones

  14. Oct 14, 2005

    Heat and Air Duct Inspection

    Inspected by Randy Jones

  15. Oct 14, 2005

    Framing Inspection

    Inspected by Randy Jones

  16. Mar 9, 2006

    Permanent Power Inspection

    Inspected by Randy Jones

  17. Mar 9, 2006

    Permanent Power Inspection

    Inspected by Randy Jones

  18. Aug 3, 2006

    Final Inspection

    Inspected by Randy Jones

  19. Aug 3, 2006

    CERTIFICATE OF OCCUPANCY/COMPLETION DATE

  20. Aug 3, 2006

    Final Inspection

    Inspected by Randy Jones