Columbia County is committed to ensuring accessibility to this website regardless of disability. If anyone encounters a feature on this website that is inaccessible due to a disability, please contact the County Manger’s Office and the Columbia County Board of County Commissioners at (386) 758-1005. You may also email that office at patrick_weaver@columbiacountyfla.com and provide a brief description of the inaccessible feature. The County will either correct the inaccessible feature or, if correction is not possible due to technical limitations, provide the desired information through alternative means.

Skip to content

Columbia County, FL | Permit Details

New Residential Construction Permit
Address 115 SW CHALLENGER LN
LAKE CITY, FL 32025
Parcel #: 08106-102
Acres: 0.58
Owner: Campbell William L
Subdivision: Country Landings
Zoning: RSF-2
Flood Zone: X
District: 5
Application #: 48180
Permit #: 000041263
Related Permit:
Submitted: Friday, January 15, 2021
Issued: Thursday, February 4, 2021
Expires: Thursday, July 8, 2021
Completed: Thursday, July 8, 2021
Status: Completed
Septic Release? Yes
Notes:
PERMIT 28892 - HANGAR, WHICH HAS BEEN COMPLETED
Job Details
This is the construction of a Single Family Dwelling
If Other, explain the use of the structure. SFR attached to the Hangar BY BREEZEWAY
Heated Area (Sqft) 1370
Total Area (Sqft) 2396
Stories 1
Building Height 16.6
Building Code Construction Type V
Building Code Element B
Building Code Occupancy Types Residential
Occupancy Use Title single family
Setbacks Front 25'
Setback Side 1 10'
Setback Side 2 10'
Setbacks Rear 15'
Septic# (00-0000) or (X00-000) 21-0050
Building Code Edition 2020 Florida Building Code 7th Edition and 2017 National Electrical Code
Elevation regulation Minimum Requirement
Finished floor requirement One foot above the road
Fema map number 12023C0293D
In floodway N
Review Notes
1/14/2021 Application pending.
1/15/2021 Point Review - Printed-Online Application BRITTANY: CHRIS WILLIAMS - CURRENT STALTE LICENSE & LIABILITY EH 911 RES. CHECKLIST PRODUCTS APPROVAL#'S SUB-VF
1/19/2021 Zoning Review - Reviewed BRITTANY: CHRIS WILLIAMS - CURRENT STATE LICENSE & LIABILITY EH 911 RES. CHECKLIST PRODUCTS APPROVAL#'S SUB-VF OWNER'S PHONE #
1/21/2021 Plan Review - Documents Required BRITTANY: CHRIS WILLIAMS - CURRENT STATE LICENSE & LIABILITY EH 911 PRODUCTS APPROVAL#'S SUB-VF OWNER'S PHONE #
1/25/2021 Plan Review - Documents Required BRITTANY: CHRIS WILLIAMS - CURRENT LIABILITY EH 911 PRODUCTS APPROVAL#'S SUB-VF OWNER'S PHONE #
1/27/2021 Plan Review - Reviewed BRITTANY: CHRIS WILLIAMS - CURRENT LIABILITY - 1.26.21 EH-REC'D 1/25 911- REC'D 1/25 PRODUCTS APPROVAL#'S-REC'D 1/25 SUB-VF-REC'D 1/25 OWNER'S PHONE #- REC'D 1.25.21
2/3/2021 Zoning Review - Reviewed BRITTANY: CHRIS WILLIAMS - CURRENT LIABILITY - 1.26.21 EH-REC'D 1/25 911- REC'D 1/25 PRODUCTS APPROVAL#'S-REC'D 1/25 SUB-VF-REC'D 1/25 OWNER'S PHONE #- REC'D 1.25.21
2/3/2021 Final Review - Payment Needed BRITTANY: CHRIS WILLIAMS - CURRENT LIABILITY - 1.26.21 EH-REC'D 1/25 911- REC'D 1/25 PRODUCTS APPROVAL#'S-REC'D 1/25 SUB-VF-REC'D 1/25 OWNER'S PHONE #- REC'D 1.25.21
2/4/2021 Permit Issued Permit #000041263 created and approved.
Contractors
Name/ Business License Title Role
Cody Barrs
Barrs Plumbing Inc
CFC1427145 Plumbing Contractor Subcontractor
Tabitha M Sibel
Rjh Construction
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CCC1331967 Cert. Roofing Subcontractor
Ryan C Beville
Rbi Electrical Contracting Llc
EC13004236 Electrical Contractor Subcontractor
Christopher Williams
Christopher A Williams Inc Dba-country Comfort Heating & Ac
County License & State License & Liability Insurance & Workers Comp Expired.
CAC057795 Class "b" A/c Subcontractor
Tabitha M Sibel
Rjh Construction
County License & State License & Liability Insurance & Workers Comp & Employees Workers Comp Expired.
CGC1515388 General Contractor Contractor
Inspections
Inspection Notes Performed By Date
Passed: Building - Footer Need Picture Of Grounding Wire Anthony Aslan 2/17/2021
Passed: Engineering - Setbacks Anthony Aslan 2/17/2021
Failed: Building - Slab Welded Wire Mesh On Chairs Matt Forsyth 3/16/2021
Passed: Building - Slab Matt Forsyth 3/17/2021
Septic Release Inspection Health Dept 3/19/2021
Passed: Building - Roof Decking Matt Forsyth 4/9/2021
Passed: Building - Wall Sheathing Matt Forsyth 4/9/2021
Passed: Building - Strapping Matt Forsyth 4/14/2021
Passed: Building - Roof Decking Matt Forsyth 4/14/2021
Passed: Electrical - 2nd Rough-In Matt Forsyth 4/26/2021
Failed: Mechanical - Rough In Need Ductwork Complete Matt Forsyth 4/26/2021
Passed: Plumbing/Gas - 2nd Rough-In Matt Forsyth 4/26/2021
Passed: Mechanical - Rough In Matt Forsyth 4/27/2021
Failed: Building - Framing Truss Engineering Not Complete Matt Forsyth 4/27/2021
Passed: Building - Insulation Matt Forsyth 5/4/2021
Passed: Building - Framing Matt Forsyth 5/4/2021
Failed: Building - Final Need Blower Door Test, And Complete Handrails At Front. Troy Crews 6/25/2021
Failed: Building - Final Blower Door Test Under 3.00 Need Mechanical Fresh Air Matt Forsyth 6/29/2021
Passed: Building - Final Matt Forsyth 7/8/2021