Permit Details

Permit Search

Permit

New Residential Construction

500 SW SUNNY ACRES GLN
LAKE CITY, FL 32024

Permit #
000056688
Application #
77287
Status Permit Reissued
  1. Submitted Sep 25, 2026
  2. Issued Oct 29, 2026
  3. Expires Oct 29, 2027
  4. Completed —

Property

Parcel #
03525-217
Owner
Laughlin Perry M, Laughlin Leanna L
Acres
1.93
Subdivision
Sunny Acres Unit 3 Unr
Zoning
ESA-2
Flood zone
X
District
2

Permit

Status
Permit Reissued
Septic release
Not yet released
Related permit
—

Job Details

Elevation regulation
Minimum Requirement
Finished floor requirement
One foot above the road
Fema map number
12023C0390C
This is the construction of a
Single Family Dwelling
Setbacks Front
30'
Setback Side 1
25'
Setback Side 2
25'
Setbacks Rear
25'
Stories
1
Heated Area (Sqft)
1600
Total Area (Sqft)
2000
Building Height
20
Building Code Construction Type
V
Building Code Element
B
Building Code Occupancy Types
Residential
Occupancy Use Title
SINGLE FAMILY DWELLING
Building Code Edition
2023 FLORIDA BUILDING CODE 8TH EDITION AND 2020 NATIONAL ELECTRICAL CODE
Septic# (00-0000) or (X00-000)
26-0609
Sealed roof decking options. (Must select one option per FBC 2023 8th Edition)
a minimum 4-inch wide strip of selfadhering polymer-modified bitumen complying with ASTM D1970 or a minimum 3 ¾ - inch wide strip of selfadhering flexible flashing tape complying with AAMA 711, applied over all joints in the roof decking. A felt underlayment complying with ASTM D226 Type II, ASTM D4869 Type Ill or IV, or ASTM D6757, or a synthetic underlayment meeting the performance requirements specified, is required to be applied over the strips/tape over the entire roof.
Service Amps
200

Status & Review History

  1. Application pending.
  2. 911 Address Form was not accepted.
  3. Application Status Update Notification
  4. Application Status Update Notification
  5. Application Status Update Notification
  6. Application Status Update Notification
  7. Application Status Update Notification
  8. Application Status Update Notification
  9. Application Status Update Notification
  10. Application Status Update Notification
  11. Application Status Update Notification
  12. Application Status Update Notification
  13. Application Status Update Notification
  14. Application Status Update Notification
  15. Application Status Update Notification
  16. Application Status Update Notification
  17. Application Status Update Notification
  18. Application Status Update Notification
  19. Application Status Update Notification
  20. Application Status Update Notification
  21. Application Status Update Notification
  22. Application Status Update Notification
  23. Application Status Update Notification
  24. Application Status Update Notification
  25. Application Status Update Notification
  26. Application Status Update Notification
  27. Application Status Update Notification
  28. Application Status Update Notification
  29. Application Status Update Notification
  30. New address issued and ticket completed.
  31. Application Status Update Notification
  32. Submitted by building department on applicant's behalf
  33. Application Status Update Notification
  34. Application Status Update Notification
  35. Permit Issued
  36. Permit Reissued
  37. Permit Reissued
  38. Permit Reissued
  39. Permit Reissued
  40. Permit Reissued
  41. Permit Reissued

Contractors

This is an owner-builder project.

  • Everton D Ruddock

    D&s Lighting Inc

    License
    EC13003800
    Title
    Electrical Contractor
    Role
    Subcontractor
  • Kenneth R Roche

    Ken Roche Plumbing Inc Dba Plumbing Now

    License
    CFC1426527
    Title
    Plumbing Contractor
    Role
    Subcontractor
  • Derrick L Williams

    D L Williams Heating & Cooling Llc

    License
    CAC1816913
    Title
    Class "b" A/c Contractor
    Role
    Subcontractor
  1. Oct 12, 2026

    Passed: Building - Footer

    Inspected by Christian Allen

  2. Oct 12, 2026

    Passed: Electrical - Footer Steel & Grounding

    Inspected by Christian Allen

  3. Oct 12, 2026

    Passed: Engineering - Setbacks

    Inspected by Christian Allen

  4. Oct 28, 2026

    Passed: Plumbing/Gas - 1st Underground Rough–In

    Inspected by Gary Pitzer

  5. Nov 3, 2026

    Passed: Building - Slab

    Inspected by Gary Pitzer

  6. Nov 17, 2026

    Passed: Electrical - Temporary Power Service

    Inspected by Gary Pitzer